Sub topic 12
How X-rays are produced
This chapter covers the Coolidge tube: how it makes X-rays, which controls set the number and the energy of the photons, and how much of the input power becomes X-rays. It assumes you know kinetic energy and the electron-volt, electric potential difference, and the photon relation E = hf = hc/λ with hc ≈ 1240 eV·nm. Later chapters work out the continuous spectrum and Moseley's law in detail. Here the focus is the tube itself and the energy accounting.
What X-rays are
X-rays are electromagnetic waves with wavelengths from about 0.01 nm to 10 nm (0.1 Å to 100 Å). In photon terms they carry roughly 100 eV to 100 keV. They are produced when fast electrons are stopped by matter. They are not produced by the nucleus. Two separate processes occur when electrons hit a target, and both are covered in this tutorial:
- Sudden deceleration of electrons in the electric field of target nuclei gives a continuous range of wavelengths (bremsstrahlung, "braking radiation").
- Knocking out an inner-shell electron of a target atom, followed by an outer electron dropping into the vacancy, gives sharp lines (characteristic X-rays).
The Coolidge tube
W. D. Coolidge's design (1913) replaced the older gas-discharge tube. It is a sealed glass tube with a high vacuum. A vacuum is needed so that electrons travel from cathode to target without colliding with gas molecules. The tube has these parts:
- Filament (cathode). A coil of tungsten heated by its own low-voltage supply. At high temperature it emits electrons by thermionic emission.
- Focusing cup. A metal cup around the filament, at cathode potential, that pushes the electrons into a narrow beam aimed at one small spot on the target.
- Target (anode). A block of a high-melting-point, high-atomic-number metal such as tungsten or molybdenum, set at an angle to the beam. It is held at a high positive potential relative to the filament.
- High-voltage supply. It provides the accelerating potential difference V between filament and target, typically 10 kV to 100 kV for diagnostic use and higher for industrial work.
- Cooling. The target is mounted on a copper stem or cooled by water, oil, or rotation, because most of the beam energy becomes heat.
Two independent controls
The tube has two electrical circuits, and each controls a different property of the beam.
| Control | What it changes | Effect on X-rays |
|---|---|---|
| Filament current (heating) | Filament temperature, hence the number of electrons emitted per second, hence the tube current I | Intensity: the number of photons per second. Wavelengths are unchanged. |
| Accelerating voltage V | Kinetic energy of each electron on arrival | Quality or hardness: the shortest wavelength and the penetrating power. Also raises intensity somewhat. |
This separation is a frequent JEE question. Raising the filament current makes the filament hotter and emits more electrons per second. It does not change the energy of each electron, because that is set by V alone. Raising V changes the energy of each electron and therefore the shortest wavelength. It does not, by itself, change the number of electrons leaving the filament, which is set by temperature (in the usual saturated operating regime).
Energy of the electrons
An electron starts essentially at rest at the filament and is accelerated through a potential difference V. By energy conservation:
K = eV
where e = 1.6 × 10⁻¹⁹ C. In electron-volts, an electron accelerated through 20 kV has K = 20 000 eV. The speed follows from K = ½mv² (use the relativistic form for tens of kV and above if you need accuracy, since the nonrelativistic result becomes noticeably high near 100 kV, but JEE numerical problems use the nonrelativistic form).
The electron current is I = n e, where n is the number of electrons striking the target per second. The power delivered to the target is
P = IV
For example, a tube at 20 kV and 10 mA delivers 200 W to a spot that may be only a millimetre or so across.
Where the energy goes
When an electron enters the target it interacts with many atoms. Most of those interactions are collisions with the target's electrons that excite or free them, and the energy ends up as heat in the lattice. Only a small fraction of the electrons produce an X-ray photon, and often the photon takes only part of the electron's energy.
An approximate efficiency for X-ray production is
η ≈ 10⁻⁹ Z V
with V in volts and Z the atomic number of the target. For tungsten (Z = 74) at 100 kV this gives about 0.7%. The efficiency rises with Z and with V. This is why the target is a high-Z metal, and why X-ray tubes are inefficient: about 99% of the power is heat. The target must therefore have a high melting point (tungsten melts near 3680 K) and good heat conduction away from the focal spot.
e = 1.6e-19 # C
m = 9.11e-31 # kg
V = 20_000 # accelerating voltage in volts
I = 10e-3 # tube current in amperes
Z = 74 # tungsten
kinetic_eV = V # K = eV, numerically V in eV
v = (2 * e * V / m) ** 0.5 # nonrelativistic speed in m/s
electrons_per_s = I / e # n = I / e
power_W = I * V # P = IV
efficiency = 1e-9 * Z * V # rough fraction converted to X-rays
xray_power_W = efficiency * power_W
heat_W = power_W - xray_power_W
print(kinetic_eV)
print(f"{v:.3e}")
print(f"{electrons_per_s:.3e}")
print(power_W)
print(f"{efficiency:.4f}")
print(f"{xray_power_W:.2f}")
print(f"{heat_W:.2f}")Running this gives a speed near 8.4 × 10⁷ m/s (about 0.28c, so the nonrelativistic result is only roughly right), about 6.25 × 10¹⁶ electrons per second, and a power of 200 W. The efficiency is about 0.0015, so only about 0.3 W emerges as X-rays and about 199.7 W is heat.
Why the spectrum has two parts
A single electron beam, all with the same energy eV, produces a spectrum with two different features.
- A continuous background. An electron slowing down in the field of a nucleus loses energy as a photon. Different electrons lose different amounts, in different numbers of steps, so photon energies spread from nearly zero up to a maximum of eV. This gives a smooth curve with a sharp short-wavelength limit λ_min = hc/(eV).
- Sharp lines on top. If V is high enough, an incoming electron can eject an inner electron (for example from the K shell). An electron from a higher shell then falls into the hole and emits a photon with energy equal to the difference of the two levels. These energies depend only on the target element, not on V.
The next two chapters treat each in turn. For production, the key point is the threshold condition for characteristic lines: the electron energy eV must exceed the binding energy of the inner shell. Below that voltage the tube gives only the continuous spectrum.
Common errors
- Saying filament current sets the photon energy. It sets the number of photons. The photon energy limit is set by V.
- Confusing the two voltages. The heating voltage (a few volts) only warms the filament. The accelerating voltage (tens of kV) is what gives electrons their energy.
- Treating X-rays as emitted by the nucleus. They come from electrons, either decelerating or changing shells. Gamma rays are the nuclear counterpart.
- Applying K = eV with V in kilovolts but using joules. If V is in volts and e in coulombs, K is in joules. If you work in eV, K is numerically V in volts.
- Expecting high efficiency. Most of the beam power is heat. Quoting efficiency near 1 is wrong.
- Forgetting the vacuum. In a gas-filled tube, electrons would lose energy on collisions before reaching the target, and the filament would oxidize.
Worked example
An X-ray tube operates at 30 kV with a tube current of 5 mA. Find (a) the kinetic energy of an electron on arrival in eV and in joules, (b) the number of electrons striking the target per second, (c) the input power, and (d) the heat produced per second if 0.5% of the power is converted to X-rays.
(a) K = eV = 30 keV = 30 000 eV. In joules, 30 000 × 1.6 × 10⁻¹⁹ = 4.8 × 10⁻¹⁵ J.
(b) n = I/e = 5 × 10⁻³ / 1.6 × 10⁻¹⁹ ≈ 3.1 × 10¹⁶ electrons per second.
(c) P = IV = 5 × 10⁻³ × 30 000 = 150 W.
(d) X-ray power = 0.005 × 150 = 0.75 W, so heat = 150 − 0.75 = 149.25 W.
If the filament current is now increased so that the tube current doubles to 10 mA while V stays at 30 kV, the electron energy and the shortest wavelength do not change. The photon count rises, and the input power doubles to 300 W.
Exercise
An X-ray tube runs at 40 kV and 8 mA. (a) What is the kinetic energy of each electron reaching the target, in eV? (b) How many electrons strike the target each second? (c) If only 1% of the input power becomes X-rays, how much heat must be removed each second?
Show answer
(a) K = eV = 40 000 eV (6.4 × 10⁻¹⁵ J). (b) n = I/e = 8 × 10⁻³ / 1.6 × 10⁻¹⁹ = 5 × 10¹⁶ per second. (c) Input power P = IV = 8 × 10⁻³ × 40 000 = 320 W. X-ray power is 3.2 W, so heat is 320 − 3.2 = 316.8 W, about 317 W per second (317 J each second).
Exercise
In a Coolidge tube the filament current is increased while the accelerating voltage is kept constant. State what happens to (a) the minimum wavelength of the X-rays and (b) the total intensity. Then state what happens to the minimum wavelength if the accelerating voltage is instead doubled with the filament current unchanged.
Show answer
(a) The minimum wavelength does not change, because λmin = hc/(eV) depends only on V. (b) The intensity increases, because a hotter filament emits more electrons per second, so more electrons strike the target and more photons are produced. If V is doubled, each electron has twice the energy, so λmin is halved.