Sub topic 16
Finding an unknown resistance with a meter bridge
This chapter assumes you know the Wheatstone balance condition P/Q = R/S from the previous chapter. It also assumes you know that resistance is proportional to length for a uniform wire (R = ρL/A). Here you will see how a stretched wire replaces two of the four bridge resistances, and how that gives a practical way to measure an unknown resistance.
From the Wheatstone bridge to the meter bridge
A meter bridge (also called a slide wire bridge) is a Wheatstone bridge built on a single uniform wire. Its parts are:
- A wire of 100 cm length, usually of manganin or constantan, stretched along a wooden board beside a metre scale. The wire has the same cross-section and material everywhere.
- Two L-shaped copper strips at the ends. A middle copper strip separates two gaps: the left gap and the right gap.
- The unknown resistance X, connected in the left gap.
- A known resistance S, taken from a resistance box, connected in the right gap.
- A jockey, a sliding contact that touches the wire at a chosen point D.
- A galvanometer, connected between the middle strip and the jockey.
- A cell and a key, connected across the two ends of the wire.
The wire itself supplies the other two arms of the bridge. If the jockey touches the wire at a distance l from the left end, the wire is split into a piece of length l and a piece of length (100 − l). Because the wire is uniform, their resistances are in the same ratio as their lengths.
Deriving the working formula
Let r be the resistance of the wire per centimetre. The two wire segments have these resistances:
- Segment AD, of length l: P = r·l
- Segment DC, of length (100 − l): Q = r·(100 − l)
The bridge arms are X and S on one side, and P and Q on the other. At balance the galvanometer shows no deflection, and the balance condition gives:
X / S = P / Q = (r·l) / (r·(100 − l))
The factor r cancels, so:
X = S · l / (100 − l)
Here l is measured from the end of the wire that is nearer to X. Keep this orientation in mind. If you measure l from the wrong end, you get the reciprocal ratio and a wrong answer.
You could also name the arms in the earlier P/Q = R/S form. Then P is the resistance of the left wire segment, Q is that of the right segment, R is X and S is S. The result is the same, because the ratio is what matters.
Procedure
- Connect the circuit as described above. Put X in the left gap and a resistance box in the right gap.
- Take a suitable S out of the box, so that the balance point falls near the middle of the wire.
- Close the key. Touch the jockey briefly at the two ends of the wire. The galvanometer should deflect in opposite directions at the two ends. If it deflects the same way at both ends, there is a fault in the circuit, such as a loose connection or a wrong terminal.
- Slide the jockey until the galvanometer shows zero deflection. Read l.
- Open the key. Calculate X = S·l/(100 − l).
- Repeat for several values of S and average the values of X.
The jockey should only tap the wire. Dragging it along the wire scratches it and changes the cross-section locally, which breaks the assumption of uniformity.
Why the balance point should be near 50 cm
A reading error in l changes the computed X. Taking logarithms of X = S·l/(100 − l) and differentiating gives:
ΔX / X = Δl / l + Δl / (100 − l) = 100·Δl / (l·(100 − l))
For a fixed Δl, this fractional error is smallest when the product l·(100 − l) is largest. That product is largest at l = 50 cm, where it equals 2500. At l = 50, X = S, so the best accuracy comes from choosing S close to X. The program below shows the effect for a reading uncertainty of 0.1 cm.
def unknown_resistance(S, l, length=100.0):
"""X from the known resistance S and the balance length l (from the X end)."""
return S * l / (length - l)
def relative_error(l, dl=0.1, length=100.0):
"""Fractional error in X for a reading uncertainty dl in the balance length."""
return dl * length / (l * (length - l))
print(round(unknown_resistance(10, 40), 2)) # 6.67 ohm
for l in (10, 30, 50, 70, 90):
print(l, f"{100 * relative_error(l):.2f} %")
# 10 -> 1.11 %, 30 -> 0.48 %, 50 -> 0.40 %, 70 -> 0.48 %, 90 -> 1.11 %Sources of error and how to reduce them
The ideal formula assumes that the wire is perfectly uniform and that the only resistances in the bridge arms are X, S and the wire segments. Real apparatus departs from this in several ways.
- End resistances. The copper strips and the contacts at the ends of the wire add small resistances, equivalent to extra wire lengths α and β at the two ends. The balance condition is then X/S = (l + α)/(100 − l + β), and the simple formula is slightly off.
- Non-uniform wire. If the cross-section varies, the resistance is no longer proportional to length.
- Heating. A continuous current warms the wire. Resistance then rises with temperature (as covered in the chapter on temperature dependence), and the wire's ratio changes. Keep the key open between readings.
- Poor contacts. Loose connections add unknown resistance to the arms.
- Parallax and scale reading. Read the scale directly above the jockey.
A standard method removes end corrections without needing to know α or β. Interchange X and S, so that X is in the right gap and S in the left, and find a new balance length l′. Then average the two results for X. The end effects enter the two measurements in opposite directions, so they largely cancel.
Worked example
A coil of unknown resistance X is placed in the left gap. A resistance box in the right gap is set to S = 12 Ω. The jockey balances the bridge at l = 25 cm from the left end.
- The other segment is 100 − 25 = 75 cm.
- X = S·l/(100 − l) = 12 × 25 / 75 = 4 Ω.
Check by ratio: X/S = 4/12 = 1/3, and l/(100 − l) = 25/75 = 1/3. The two ratios agree. This X is smaller than S, so the balance point sits in the left half of the wire, nearer to X. As a general rule, the balance point moves toward the smaller resistance.
Now suppose the two resistances were interchanged. The new balance length, measured from the left end, would be 75 cm. This is a quick check on any numerical: the sum of the two balance lengths from an interchange is 100 cm when end corrections are zero.
Summary of key relations
| Quantity | Expression |
|---|---|
| Wire segment resistances | P = r·l, Q = r·(100 − l) |
| Balance condition | X/S = l/(100 − l) |
| Unknown resistance (X in left gap) | X = S·l/(100 − l) |
| Fractional error from reading error Δl | 100·Δl / (l·(100 − l)) |
| Best balance point | l = 50 cm, where X = S |
Exercise
In a meter bridge, the unknown resistance X is in the left gap and a known resistance S = 5 Ω is in the right gap. The galvanometer shows zero deflection when the jockey is at 40 cm from the left end. Find X. Then find where the balance point would be if X and S were interchanged, ignoring end corrections.
Show answer
X = S·l/(100 − l) = 5 × 40 / 60 = 3.33 Ω (about 10/3 Ω). After interchange, the 5 Ω resistance is in the left gap and 3.33 Ω is in the right gap. The new balance length l′ satisfies 5/3.33 = l′/(100 − l′), so l′/(100 − l′) = 1.5, which gives l′ = 60 cm. This equals 100 − 40, as expected when end corrections are zero.
Exercise
A meter bridge measures an unknown resistance with a reading uncertainty of 0.1 cm in the balance length. Compare the fractional error in X when the balance point is at 50 cm and when it is at 10 cm. Which is better, and why?
Show answer
The fractional error is 100·Δl / (l·(100 − l)). At l = 50 cm it is 100 × 0.1 / 2500 = 0.004, which is 0.4 %. At l = 10 cm it is 100 × 0.1 / 900 = 0.0111, which is about 1.1 %. The balance point at 50 cm is better, because the product l·(100 − l) is largest there, so the same reading error causes the smallest relative change in X. In practice you adjust S until it is close to X.