Sub topic 8
Electrical power and Joule heating
This chapter assumes you know current, potential difference, Ohm's law and how to find the equivalent resistance of series and parallel networks. It covers how fast a circuit element converts electrical energy into other forms, why resistors get hot, and how to compare power in series and parallel arrangements. These ideas appear in many NEET questions on bulbs, heaters and fuses.
Power as energy per unit time
When charge dq moves through a potential difference V, the electric field does work dW = V dq. Power is the rate of doing work, so:
P = dW/dt = V (dq/dt) = VI
This holds for any element that has a potential difference V across it and a current I through it. The element may be a resistor, a motor or a cell being charged. The unit is the watt (W), where 1 W = 1 V × 1 A = 1 J/s.
For a resistor that obeys Ohm's law (V = IR), you can rewrite this in three equivalent forms:
| Form | Use it when |
|---|---|
| P = VI | You know voltage and current |
| P = I²R | You know the current, for example resistors in series |
| P = V²/R | You know the voltage, for example resistors in parallel |
The forms I²R and V²/R apply only to ohmic resistors. P = VI is more general.
Why a resistor heats up
Inside a conductor, free electrons gain kinetic energy from the field. They then collide with the lattice ions and pass that energy to them. The electrons keep a roughly constant drift velocity, so the energy the field supplies does not accumulate as electron kinetic energy. It becomes thermal vibration of the lattice, and the conductor warms.
The heat produced in time t is the Joule heating:
H = I²Rt = VIt = (V²/R)t
H is in joules when I is in amperes, R in ohms and t in seconds. This is Joule's law of heating.
Units and the kilowatt-hour
Household energy is billed in kilowatt-hours (kWh). One kWh is the energy used by a 1 kW device running for 1 hour:
1 kWh = 1000 W × 3600 s = 3.6 × 10⁶ J
One "unit" on an electricity bill is 1 kWh.
def energy_kwh(power_watts, hours):
return power_watts * hours / 1000
def cost(power_watts, hours, rate_per_kwh):
return energy_kwh(power_watts, hours) * rate_per_kwh
# A 2000 W heater run for 3 hours at 8 rupees per unit
print(energy_kwh(2000, 3)) # 6.0 kWh
print(cost(2000, 3, 8)) # 48.0 rupees
print(energy_kwh(2000, 3) * 3.6e6) # 21600000.0 JRated power and the rating of a bulb
A bulb marked "100 W, 220 V" means it dissipates 100 W when operated at 220 V. From P = V²/R, its resistance is:
R = V²/P = 220²/100 = 484 Ω
Treat this resistance as fixed in typical NEET problems. If the supply voltage differs from the rated voltage, the actual power is:
P' = V'²/R = P (V'/V)²
So a 100 W, 220 V bulb on a 110 V supply gives 100 × (1/2)² = 25 W.
def bulb_resistance(rated_power, rated_voltage):
return rated_voltage ** 2 / rated_power
def actual_power(rated_power, rated_voltage, applied_voltage):
r = bulb_resistance(rated_power, rated_voltage)
return applied_voltage ** 2 / r
print(bulb_resistance(100, 220)) # 484.0 ohm
print(actual_power(100, 220, 110)) # 25.0 WPower in series and parallel networks
The same set of resistors behaves differently in the two arrangements, so choose the power formula that uses the quantity that is shared.
- In series, the current I is common. Power P = I²R is proportional to R, so the largest resistance dissipates the most power and glows brightest.
- In parallel, the voltage V is common. Power P = V²/R is inversely proportional to R, so the smallest resistance dissipates the most power.
Take two bulbs, 100 W and 60 W, both rated for 220 V. The 100 W bulb has the smaller resistance (484 Ω against about 807 Ω). In parallel on 220 V, the 100 W bulb is brighter. In series, the 60 W bulb has the larger resistance, so it is brighter.
The total power from the source equals the sum of the powers in the individual resistors. This follows from conservation of energy and holds for both arrangements.
Power with equal resistors is a frequent test. Suppose two identical resistors R are connected to the same fixed-voltage source V. In series the equivalent resistance is 2R, so the total power is V²/(2R). In parallel it is R/2, so the total power is 2V²/R. The parallel arrangement gives four times the power of the series arrangement.
def total_power(voltage, *resistances, mode="series"):
if mode == "series":
req = sum(resistances)
else:
req = 1 / sum(1 / r for r in resistances)
return voltage ** 2 / req
R = 10.0
V = 20.0
p_series = total_power(V, R, R, mode="series")
p_parallel = total_power(V, R, R, mode="parallel")
print(p_series, p_parallel, p_parallel / p_series) # 20.0 80.0 4.0Power delivered to a load from a real cell
A cell with emf E and internal resistance r drives a current I = E/(R + r) through an external resistor R. The power delivered to R is:
P = I²R = E²R/(R + r)²
The cell also dissipates I²r inside itself, and the total power supplied by the chemical energy is EI. These satisfy EI = I²R + I²r.
The delivered power depends on R. It is zero at R = 0 and approaches zero as R becomes very large, so it has a maximum in between. Setting dP/dR = 0 gives:
R = r
This is the maximum power transfer condition. At that point:
P_max = E²/(4r)
The efficiency at maximum power is only 50%, because half of the supplied power is lost in r.
import numpy as np
E, r = 12.0, 2.0
R = np.linspace(0.1, 10, 100)
P = E ** 2 * R / (R + r) ** 2
best = R[np.argmax(P)]
print(round(best, 2)) # close to 2.0, which equals r
print(round(P.max(), 2)) # close to E**2 / (4*r) = 18.0
print(E ** 2 / (4 * r)) # 18.0Worked example: a heater and a fuse
An immersion heater is rated 1 kW at 220 V. It heats 2 kg of water from 20 °C to 70 °C. The specific heat of water is 4200 J/(kg·K). Assume all the heat goes to the water.
- Heat needed: Q = mcΔT = 2 × 4200 × 50 = 4.2 × 10⁵ J.
- Time taken: t = Q/P = 4.2 × 10⁵ / 1000 = 420 s, or 7 minutes.
- Current drawn: I = P/V = 1000/220 ≈ 4.55 A.
- Resistance: R = V²/P = 220²/1000 = 48.4 Ω.
m, c, dT = 2.0, 4200.0, 50.0
P, V = 1000.0, 220.0
Q = m * c * dT
t = Q / P
I = P / V
R = V ** 2 / P
print(Q, t, round(I, 2), R) # 420000.0 420.0 4.55 48.4A fuse works on the same principle. It is a wire with a low melting point. If the current exceeds its rating, I²Rt heating melts the wire and opens the circuit. A fuse must be placed in series with the load. It must be rated slightly above the normal current. A 1 kW heater on 220 V draws about 4.55 A, so a 5 A fuse is a sensible choice.
Common errors
- Using P = V²/R with the source voltage when the resistor only receives part of it, as in a series chain. Use the voltage across that resistor.
- Assuming the brighter bulb is always the one with higher rated power. In series the lower-rated bulb has more resistance and glows brighter.
- Applying I²R and V²/R to a device that does not follow Ohm's law, such as a motor. Its input power is still VI, but not all of it becomes heat.
- Confusing power with energy. Watts measure a rate. Joules and kilowatt-hours measure energy.
- Reading maximum power transfer as maximum efficiency.
- Forgetting that the rated resistance of a bulb is found from rated values, then reused at a different voltage.
Exercise
Two bulbs, 60 W and 100 W, both rated for 220 V, are connected in series across a 220 V supply. (a) Which bulb glows brighter? (b) What is the total power drawn from the supply? Take the resistances as fixed at their rated values.
Show answer
Resistances: R1 = 220²/60 ≈ 806.7 Ω for the 60 W bulb and R2 = 220²/100 = 484 Ω for the 100 W bulb. (a) In series the current is common and P = I²R, so the bulb with the larger resistance, the 60 W bulb, glows brighter. (b) The total resistance is 806.7 + 484 = 1290.7 Ω, so the total power is 220²/1290.7 ≈ 37.5 W.
Exercise
A cell of emf 6 V and internal resistance 1.5 Ω is connected to an external resistor R. Find R for maximum power in R, the maximum power, and the efficiency at that point.
Show answer
Maximum power occurs when R = r = 1.5 Ω. Then P_max = E²/(4r) = 36/6 = 6 W. The current is 6/(1.5 + 1.5) = 2 A, and the power supplied by the cell is EI = 12 W, so the efficiency is 6/12 = 50%.
Exercise
A 2 kW heater runs for 30 minutes each day. At a rate of 7 rupees per unit, what does it cost to run it for 30 days?
Show answer
Daily energy = 2 kW × 0.5 h = 1 kWh. Over 30 days this is 30 kWh. The cost is 30 × 7 = 210 rupees.