Sub topic 14
Measuring with a multimeter
This chapter assumes you know V = IR, series and parallel resistor rules, and the idea of a voltmeter reading a potential difference. A multimeter measures voltage, current, and resistance. Each mode connects to the circuit differently, and mistakes with that connection are the most common source of wrong readings and blown fuses.
The three connections
The meter's placement in the circuit follows from what each quantity means.
- Voltage is a difference between two points, so you touch the probes across the component. The meter is in parallel with it.
- Current is a flow through a path, so you break the circuit and insert the meter into the gap. The meter is in series.
- Resistance is measured by the meter itself, which pushes a small test current through the part. The part must be removed from power and, ideally, isolated from the rest of the circuit.
Why the meter changes the circuit
A real meter is not invisible. Its internal resistance disturbs what it measures.
- A voltmeter has a very large input resistance, typically about 10 MΩ. It draws almost no current, so it barely changes the circuit.
- An ammeter has a very small resistance, called the burden. The voltage across it is small, but not zero.
Loading matters when the circuit's own resistances are comparable to the meter's. Take a divider of two 1 MΩ resistors fed from 10 V. The ideal midpoint voltage is 5 V. A 10 MΩ meter in parallel with the bottom resistor gives about 0.909 MΩ, so the midpoint reads about 4.76 V.
def parallel(*resistors):
return 1.0 / sum(1.0 / r for r in resistors)
def divider_out(v_in, r_top, r_bottom):
return v_in * r_bottom / (r_top + r_bottom)
r_top = 1e6
r_bottom = 1e6
r_meter = 10e6
ideal = divider_out(10.0, r_top, r_bottom)
loaded = divider_out(10.0, r_top, parallel(r_bottom, r_meter))
print(f"ideal = {ideal:.2f} V")
print(f"loaded = {loaded:.2f} V")The output is 5.00 V ideal and 4.76 V loaded. For low-resistance circuits, such as the 470 Ω example earlier, the same meter causes a negligible error.
Measuring current safely
Current mode is where most damage happens. An ammeter has almost no resistance, so placing it across a source acts like a short circuit. The current is limited only by the source and the meter's fuse, which blows.
- Turn the circuit off.
- Open the loop at one point.
- Put the red lead in the current jack and select the current range.
- Connect the meter across the gap, then power the circuit.
- Return the leads to the voltage jack when finished.
Measuring resistance
Resistance mode only gives a true reading on an unpowered part. A live circuit adds its own voltage to the meter's test signal, and the reading is meaningless. Parallel paths also matter. If the resistor is still soldered in a network, the meter reads the equivalent resistance of everything between its probes, not the part alone. Lift one lead of the component to isolate it.
Also keep your fingers off both probe tips. Your body adds a parallel resistance, which pulls high readings down.
Common errors
| Symptom | Likely cause |
|---|---|
| Meter reads 0 A in a working circuit | Blown fuse, or leads in the wrong jack |
| Voltage reads lower than calculated | Loading of a high-resistance circuit |
| Resistance reads too low in circuit | Parallel paths through other components |
| Resistance reading drifts | Power still applied, or fingers on probes |
| Reading is out of range | Range too low, so select a higher range |
Exercise
A divider has Rtop = 100 kΩ and Rbottom = 100 kΩ on a 12 V supply. You measure the midpoint with a 10 MΩ voltmeter. Roughly what does it read, and is the loading error large?
Show answer
The meter in parallel with R_bottom gives 100k × 10M / (100k + 10M) ≈ 99.0 kΩ. The midpoint is 12 × 99.0 / (100 + 99.0) ≈ 5.97 V, against an ideal 6.00 V. The error is about 0.5%, which is small for most purposes.
Exercise
You want to know the current through a 220 Ω resistor powered from 9 V. Describe how to connect the meter, and predict the reading.
Show answer
Switch to the current range, open the circuit in series with the resistor, and connect the meter across the gap. The expected current is 9 / 220 ≈ 40.9 mA, so use a range of at least 50 mA.