Sub topic 8
Efficiency at the matched load
This chapter assumes you can reduce a circuit to a Thevenin equivalent and that you know the load power model P = VTh² RL / (RTh + RL)². It also assumes you have seen that load power peaks at RL = RTh. Here we ask what fraction of the source's power reaches the load at that point.
Defining efficiency
Efficiency is the ratio of power delivered to the load to total power supplied by the source. In the Thevenin equivalent, the same current I flows through RTh and RL, so:
- Power in the load: PL = I² RL
- Power lost in RTh: PTh = I² R_Th
- Power supplied by VTh: PS = I² (RTh + RL)
The current cancels:
η = PL / PS = RL / (RTh + R_L)
Efficiency depends only on the ratio of the two resistances. It does not depend on V_Th.
The 50% result
At the matched load, RL = RTh, so η = RTh / (2 RTh) = 1/2. Half of the power the source produces is dissipated inside R_Th, and half reaches the load.
The sweep below uses a 12 V, 4 ohm Thevenin source. Load power peaks at 9 W when RL = 4 ohm. Efficiency keeps rising as RL grows.
v_th = 12.0 # volts
r_th = 4.0 # ohms
def load_power(r_load):
i = v_th / (r_th + r_load)
return i * i * r_load
for r_load in [1, 2, 4, 8, 16]:
p = load_power(r_load)
eff = r_load / (r_th + r_load)
print(f"R_L={r_load:>2} ohm P={p:.2f} W efficiency={eff:.0%}")
# Output:
# R_L= 1 ohm P=5.76 W efficiency=20%
# R_L= 2 ohm P=8.00 W efficiency=33%
# R_L= 4 ohm P=9.00 W efficiency=50%
# R_L= 8 ohm P=8.00 W efficiency=67%
# R_L=16 ohm P=5.76 W efficiency=80%At RL = 4 ohm the source supplies 18 W in total. The load gets 9 W and RTh dissipates the other 9 W.
Power and efficiency trade off
As RL grows, efficiency approaches 100%, but the current falls and so does the power delivered. As RL shrinks toward zero, the current is large but almost all the power is lost in RTh. Maximum power transfer picks the single load value where PL is largest. Maximum efficiency would need RL much larger than RTh, at the cost of delivering little power.
A common error
The 50% figure applies to the Thevenin equivalent only. The equivalent circuit reproduces the voltage and current at the load terminals. It does not reproduce what happens to power inside the original network. R_Th is a computed resistance, and the power "lost" in it is not necessarily the power lost in the real circuit. For example, a Thevenin equivalent that comes from a network containing a dependent source or a voltage divider can dissipate power in places the equivalent does not show.
So do not conclude that a real source is only 50% efficient when the load is matched. Check the actual internal dissipation of the original circuit before making that claim.
Choosing the design goal
Pick the goal from the cost of wasted power:
| Situation | Better goal | Reason |
|---|---|---|
| Small signal source, power is tiny and the source is fixed | Maximum power | Getting the most from a weak source matters more than the wasted fraction |
| Power utility or battery-powered device | High efficiency | Losses cost money or battery life, so R_L should be much larger than the source resistance |
Exercise
A source has VTh = 20 V and RTh = 5 ohm. For RL = 5 ohm and for RL = 20 ohm, find the load power and the efficiency. Which load gives more power, and which is more efficient?
Show answer
For RL = 5 ohm: I = 20 / 10 = 2 A, PL = 2² × 5 = 20 W, and η = 5 / 10 = 50%. For RL = 20 ohm: I = 20 / 25 = 0.8 A, PL = 0.8² × 20 = 12.8 W, and η = 20 / 25 = 80%. The 5 ohm load gives more power (20 W against 12.8 W). The 20 ohm load is more efficient (80% against 50%).
Exercise
What load resistance gives 90% efficiency for a source with R_Th = 3 ohm? What fraction of the maximum possible load power does that load receive?
Show answer
Solve RL / (3 + RL) = 0.9, so RL = 27 ohm. Maximum power is VTh² / (4 × 3) = VTh² / 12. At RL = 27 ohm, PL = VTh² × 27 / 30² = 0.03 V_Th². The ratio is 0.03 / (1/12) = 0.36, so the load receives 36% of the maximum power.