A brief look ahead to AC and conjugate matching
This chapter assumes you know the DC result from the earlier chapters: a load receives the most power when RL = RTh, and Pmax = VTh² / (4 R_Th). It also assumes you have met complex numbers. Impedance and phasors get a full treatment in AC analysis, so this is only a preview.
Why DC matching is not enough for AC
In an AC circuit at one frequency, the source side reduces to a Thevenin voltage VTh in series with a Thevenin impedance ZTh = RTh + jXTh. The real part RTh is resistance. The imaginary part XTh is reactance, which comes from inductors (positive X) and capacitors (negative X). The load has an impedance ZL = RL + jX_L.
Only the resistive part of the load consumes average power. Reactance stores energy and returns it each cycle. So the load's reactance affects power only by changing the current.
The conjugate matching condition
The average power in the load is, using RMS values:
P = |I|² RL, where I = VTh / (ZTh + ZL)
Maximizing P over both RL and XL gives two conditions:
- XL = -XTh, so the reactances cancel and the total reactance in the loop is zero.
- RL = RTh, the same rule as in DC.
Together these say ZL = ZTh, where the asterisk marks the complex conjugate (same real part, opposite sign of the imaginary part). This is conjugate matching*. With the reactances cancelled, the circuit behaves like the DC case, so:
Pmax = |VTh|² / (4 R_Th)
Checking it numerically
Take VTh = 12 V RMS and ZTh = 4 + j3 ohm. The code tries four loads. Python's complex type handles the arithmetic.
v_th = 12.0 # volts RMS
z_th = complex(4, 3) # ohms
def load_power(z_load):
i = v_th / (z_th + z_load) # complex current
return abs(i) ** 2 * z_load.real # only the resistive part dissipates
loads = [complex(4, -3), complex(4, 0), complex(5, 0), complex(4, 3)]
for z in loads:
label = f"{z.real:g}{z.imag:+g}j"
print(f"Z_L={label:>6} P={load_power(z):.2f} W")
# Output:
# Z_L= 4-3j P=9.00 W
# Z_L= 4+0j P=7.89 W
# Z_L= 5+0j P=8.00 W
# Z_L= 4+3j P=5.76 WThe conjugate load 4 - j3 delivers 9.00 W. This matches |VTh|² / (4 RTh) = 144 / 16. Matching only the resistance (4 + j0) loses power because the leftover reactance j3 limits the current. A load that merely matches the magnitude of Z_Th, 5 ohm, also falls short. Using the same reactance as the source (4 + j3) makes things worse, because the two reactances add.
Common errors
- Using the plain complex copy. The load must be the conjugate ZTh*, not ZTh. Equal reactances add. Opposite reactances cancel.
- Mixing peak and RMS. The formula |VTh|² / (4 RTh) assumes RMS. With a peak voltage Vp, the average power is Vp² / (8 R_Th).
- Expecting matching to hold at every frequency. Reactance depends on frequency, so a conjugate match is exact at one frequency and approximate nearby.
- Assuming 50% efficiency is a problem. As in DC, half the power is lost in the source resistance. The match is chosen for power delivered, not efficiency.
Where this appears
Conjugate matching is common in radio-frequency work, such as antennas and amplifier stages. There, small signals and weak sources make delivered power the limiting factor. Matching networks built from inductors and capacitors are placed between source and load to create the needed reactance.
Exercise
A source has VTh = 20 V RMS and ZTh = 10 - j5 ohm. What load impedance gives maximum power, and what is P_max?
Show answer
ZL = ZTh* = 10 + j5 ohm. Pmax = |VTh|² / (4 R_Th) = 400 / 40 = 10 W.
Exercise
For the same source, what is the best purely resistive load, and how much power does it receive?
Show answer
RL = |ZTh| = sqrt(10² + 5²) ≈ 11.18 ohm. Total impedance is 21.18 - j5, so |Z|² ≈ 473.6. P = 400 × 11.18 / 473.6 ≈ 9.44 W, slightly below the 10 W of the full conjugate match.