Sub topic 12
Where Matching Is Used and Where It Is Not
This chapter assumes you can reduce a linear DC circuit to a Thevenin equivalent and that you know the matching condition RL = RTh and the result Pmax = VTh² / (4 RTh). It also assumes you know that efficiency is RL / (RTh + RL), which is 50% at the match. Here we decide when to use the theorem.
Two Different Goals
The theorem answers one question: for a fixed source, which R_L gives the largest power in the load? It does not say the largest load power is what you want.
A design can pursue two goals, and they pull in opposite directions as R_L changes.
| Goal | Condition | Load power | Efficiency |
|---|---|---|---|
| Maximum power in the load | R_L = R_Th | V_Th² / (4 R_Th) | 50% |
| Maximum efficiency | R_L much larger than R_Th | Falls toward zero | Approaches 100% |
| Maximum load voltage | R_L much larger than R_Th (open circuit) | Falls toward zero | Approaches 100% |
Efficiency is the load power divided by the total power the source produces. In the equivalent circuit, the same current flows through RTh and RL, so the ratio of powers equals the ratio of resistances. At the match, R_Th dissipates as much as the load does.
The efficiency of 50% belongs to the Thevenin equivalent. The real circuit behind the equivalent may dissipate much more or less than the equivalent suggests. Chapter-level warning: the equivalent only guarantees that the load sees the same voltage and current, not that the internal power is the same.
A Sizing Example: Matching a Battery
Consider a 12 V battery with an internal resistance of 0.05 ohm. Sweep the load and watch what matching costs.
v_th = 12.0 # volts
r_th = 0.05 # ohms, battery internal resistance
for r_load in [0.05, 0.2, 0.5, 5.0]:
i = v_th / (r_th + r_load)
p_load = i * i * r_load
p_loss = i * i * r_th
eff = r_load / (r_th + r_load)
print(f"R_L={r_load} ohm I={i:.1f} A P_load={p_load:.1f} W "
f"P_loss={p_loss:.1f} W efficiency={eff:.1%}")
# Output:
# R_L=0.05 ohm I=120.0 A P_load=720.0 W P_loss=720.0 W efficiency=50.0%
# R_L=0.2 ohm I=48.0 A P_load=460.8 W P_loss=115.2 W efficiency=80.0%
# R_L=0.5 ohm I=21.8 A P_load=238.0 W P_loss=23.8 W efficiency=90.9%
# R_L=5.0 ohm I=2.4 A P_load=28.2 W P_loss=0.3 W efficiency=99.0%At the match, the load gets 720 W. The battery also converts 720 W into heat inside itself, while supplying 120 A. A battery like this would overheat, and its terminal voltage would sag to 6 V. Nobody designs a battery-powered device this way. At 0.5 ohm the load receives only about a third of the maximum power, but the battery wastes about 30 times less heat.
So for energy storage, vehicles, and portable devices, efficiency and heat matter more than the peak figure. The theorem tells you the upper bound on the power, and the bound is rarely where you want to operate.
Where Matching Is Used
Matching is the right goal when three things are true:
- The source is limited in what it can supply, because it is weak or tiny rather than a large, stiff supply.
- The power that is lost inside the source does not cost anything you care about, such as heat damage or running cost.
- Extra signal or harvested power is worth more than the efficiency lost.
These situations meet that test.
| Application | Why matching helps | What to watch |
|---|---|---|
| Radio transmitters and receivers, antennas | Delivering the most signal power to the antenna or receiver improves range and sensitivity. | Transmission lines also need matching to prevent reflections, which is a related but separate requirement. |
| Low-level sensor and transducer signals | A tiny signal source has little power, so extracting the most of it can improve the signal. | If the goal is to measure voltage, a high-impedance input is usually better. |
| Energy harvesting (small solar cells, vibration, RF) | The source is weak, and each extra microwatt is useful. | The source is often nonlinear, so the match moves with conditions. |
| Test and measurement with 50 ohm equipment | Standard source and load impedances keep cables and instruments consistent. | The 50 ohm figure is a convention, not a universal optimum. |
Radio is the classic case. Efficiency inside a small signal source is not a concern, because the source is a low-power stage. The stage that matters is the amplifier driving the antenna, and there the designers care about both the power transferred and the heat in the amplifier. Real transmitters often accept a mismatch of efficiency in exchange for other factors.
Solar panels and maximum power point tracking
A solar panel is not a linear Thevenin source. Its current-voltage curve bends. For each lighting condition there is one operating point where the product V × I is largest, called the maximum power point. A tracking converter (an MPPT controller) adjusts what the panel sees as its load until it finds that point.
The match idea survives in a local form. At the maximum power point, the load resistance V / I equals the magnitude of the panel's incremental resistance, which is the slope of its curve there. So the converter does for the panel what you do on paper for a Thevenin source: it makes the load resistance equal to the source resistance at the operating point. As light and temperature change, the point moves and the converter must follow.
Where Matching Is Not Used
Power distribution
A utility wants to deliver energy to customers with little loss. Matching would mean half of the generated power is lost in the lines and generators. Instead, the source resistance is made very small compared with the load, and the lines run at high voltage so that the current, and the I²R loss, stay low. The source stays near a constant voltage and the load takes what current it needs.
Audio amplifiers and voltage signals
A modern audio amplifier has an output resistance far below the speaker's impedance, often below 0.1 ohm against 8 ohm. This is called voltage bridging. The speaker receives nearly the full amplifier voltage regardless of small changes in its impedance, and the low source resistance helps the amplifier control the speaker cone. A matched 8 ohm output would give up half of the power as heat and would let the speaker's impedance variations change the response.
Voltage measurement
A voltmeter or an oscilloscope input has a high resistance. The aim is to disturb the circuit as little as possible, so the loading error is small. If the meter resistance were equal to the circuit's Thevenin resistance, the reading would be half the true voltage.
Power supplies and regulators
A regulated supply is designed to hold its output voltage constant as the load current varies. That means a very low output resistance, and a design that avoids operating at the match.
The Fixed-Load Case
Sometimes the load is fixed and the source resistance is the quantity you can change. The theorem then does not apply, because it assumes RTh is given and RL is free to vary.
Write the load power again:
P = VTh² RL / (RTh + RL)²
With RL fixed, the denominator only grows as RTh increases, so P falls steadily. The best choice is RTh as small as possible, ideally zero. Setting RTh equal to R_L would be a poor choice here, because it throws away power the load could have had. This is the situation when you choose cable thickness or a supply's output stage for a known load.
Practical Limits That Override the Theorem
The theorem assumes a linear source that supplies any current the load asks for. Real sources have limits.
- Current rating. The matched current is VTh / (2 RTh). If this is above the source's rating, the source cannot be matched.
- Power rating of R_Th. At the match the source's internal resistance dissipates as much as the load. A resistor or a transistor that cannot dissipate that will overheat.
- Voltage sag. At the match, the load voltage is half of V_Th. If the load needs a certain minimum voltage, matching may be unusable.
- Nonlinearity. Solar cells, batteries at high drain, and amplifiers near saturation do not follow a fixed R_Th, so the matching value changes with the operating point.
When a limit applies, the best load is the one at the limit, not at the match. For a current limit Imax, power falls as RL rises above RTh, so choose the smallest allowed RL that is at least R_Th.
def best_load(v_th, r_th, i_max):
"""Best load resistance when the source current is limited to i_max."""
r_load = max(r_th, v_th / i_max - r_th)
i = v_th / (r_th + r_load)
return r_load, i * i * r_load, r_load / (r_th + r_load)
for v, r, i_max in [(12.0, 0.05, 20.0), (12.0, 4.0, 5.0)]:
r_l, p, eff = best_load(v, r, i_max)
print(f"V_Th={v} R_Th={r} limit={i_max} A -> "
f"R_L={r_l:.2f} ohm P={p:.1f} W efficiency={eff:.1%}")
# Output:
# V_Th=12.0 R_Th=0.05 limit=20.0 A -> R_L=0.55 ohm P=220.0 W efficiency=91.7%
# V_Th=12.0 R_Th=4.0 limit=5.0 A -> R_L=4.00 ohm P=9.0 W efficiency=50.0%The battery with a 20 A limit gets 220 W at 0.55 ohm and 91.7% efficiency. The 4 ohm source needs only 1.5 A at the match, so the limit is not binding and the matched load is still best.
A Decision Guide
Common Mistakes
- Treating 50% as a loss of the whole system. It describes the equivalent circuit. Check the original circuit before drawing conclusions about heat.
- Matching a stiff source. A utility, a bench supply, or a regulator can deliver far more than a matched load is meant to draw. Matching one wastes power and may trip protection.
- Using the theorem to choose R_Th with a fixed load. The best R_Th then is as small as you can make it.
- Matching for voltage signals. If the receiver measures voltage, a high input resistance gives a larger and less disturbed signal than a matched one.
- Ignoring the ratings. The match must be checked against the current and power limits of the source.
Exercise
A sensor behaves as a 2 V Thevenin source with R_Th = 500 ohm. (a) What load gives the most power, and what is that power? (b) The amplifier you connect has an input resistance of 50 kohm, and your goal is to read the sensor voltage. What fraction of the open-circuit voltage appears at the amplifier, and why is this a better choice than the matched load for that goal?
Show answer
(a) RL = 500 ohm and Pmax = VTh² / (4 RTh) = 4 / 2000 = 2 mW. (b) By the voltage divider rule, the fraction is 50000 / (500 + 50000) = 0.990, so about 99% of 2 V, or 1.98 V, appears at the input. A matched load would give only 1 V, half of the open-circuit value. When the goal is to read voltage and not to extract power, a high input resistance loads the sensor less and is the better choice.
Exercise
A 24 V supply has RTh = 0.2 ohm and is rated for 30 A. (a) What current flows at the matched load, and can the supply be matched? (b) Using RL = max(RTh, VTh / Imax - RTh), find the best load, the power it receives, and the efficiency.
Show answer
(a) At the match, I = 24 / (0.2 + 0.2) = 60 A, which is twice the 30 A rating, so the supply cannot be matched. (b) VTh / Imax - RTh = 24 / 30 - 0.2 = 0.6 ohm, which is larger than 0.2 ohm, so RL = 0.6 ohm. The current is 24 / 0.8 = 30 A, the load power is 30² × 0.6 = 540 W, and the efficiency is 0.6 / 0.8 = 75%.