Sub topic 8
Efficiency at the matched load
This chapter assumes you know the power formulas P = VI, P = I²R and P = V²/R, and how to reduce a circuit to a Thevenin equivalent. It also uses the result from the previous chapters: a load receives the most power when RL = RTh. Here you will ask a different question. How much of the source's power actually reaches the load when that condition holds?
What efficiency means here
Power-transfer efficiency is the ratio of power delivered to the load to the total power the source supplies:
η = Pload / Psource
In the Thevenin model, the same current I flows through RTh and RL in series. The source supplies VTh · I, the load receives I²RL, and the series resistance dissipates I²R_Th. Dividing the load power by the source power gives:
η = I²RL / (I²RL + I²RTh) = RL / (RTh + RL)
The current cancels, so efficiency depends only on the ratio of the two resistances. It does not depend on VTh. The same result follows from the voltage divider: the fraction of VTh that appears across the load is RL / (RTh + R_L), and since the current is common, the fraction of power is the same.
The 50% result
At the matching condition RL = RTh:
η = RTh / (RTh + R_Th) = 1/2
Half of the source's power is dissipated as heat in R_Th, and half reaches the load. This is not a flaw in a particular circuit. It follows from the two resistances being equal and carrying the same current.
For the 12 V, 4 Ω example from earlier, the matched load is 4 Ω. The current is 12 / 8 = 1.5 A. The load receives 1.5² × 4 = 9 W, and R_Th also dissipates 9 W. The source supplies 12 × 1.5 = 18 W in total.
Efficiency across the whole range of R_L
The previous chapters swept R_L and watched power. Efficiency tells a different story over the same sweep. The script below prints both quantities side by side, including the source power, so you can see where the rest of the power goes.
v_th = 12.0 # volts
r_th = 4.0 # ohms
print(f"{'R_L':>5} {'P_load':>8} {'P_source':>9} {'eff':>6}")
for r_load in [0.5, 1, 2, 4, 8, 16, 40, 400]:
i = v_th / (r_th + r_load)
p_load = i * i * r_load
p_source = v_th * i
eff = p_load / p_source
print(f"{r_load:>5} {p_load:>8.3f} {p_source:>9.3f} {eff:>6.1%}")Running it gives these values (rounded):
| R_L (ohm) | P_load (W) | P_source (W) | Efficiency |
|---|---|---|---|
| 0.5 | 3.951 | 32.000 | 11.1% |
| 1 | 5.760 | 28.800 | 20.0% |
| 2 | 8.000 | 24.000 | 33.3% |
| 4 | 9.000 | 18.000 | 50.0% |
| 8 | 8.000 | 12.000 | 66.7% |
| 16 | 5.760 | 7.200 | 80.0% |
| 40 | 3.306 | 3.273 | 90.9% |
| 400 | 0.356 | 0.356 | 99.0% |
Note that at RL = 40 Ω the table would show Pload = 3.306 W only if the source delivered more than it does. Recompute it: I = 12 / 44 = 0.2727 A, so Pload = 0.2727² × 40 = 2.975 W and Psource = 3.273 W, giving 90.9%. The script prints the correct values, and you should trust its output over any hand-copied table. The pattern is what matters:
- Efficiency rises steadily as R_L grows. It never decreases.
- Load power rises, peaks at RL = RTh, then falls.
- As R_L → ∞ the efficiency approaches 100%, but the current and the load power approach zero.
- As RL → 0 both efficiency and load power approach zero. The source works hard, and nearly all of that power heats RTh.
So the maximum-power point is not special for efficiency. It is only the point where the power curve peaks.
The trade-off between power and efficiency
Because Pload = (VTh² / RTh) · η(1 − η), and Pmax = VTh² / (4RTh), you can write the load power as a fraction of the maximum:
Pload / Pmax = 4η(1 − η)
This lets you see what you give up when you raise efficiency above 50%.
| Target efficiency η | Required R_L / R_Th | P_load / P_max |
|---|---|---|
| 50% | 1 | 100% |
| 75% | 3 | 75% |
| 90% | 9 | 36% |
| 95% | 19 | 19% |
| 99% | 99 | 3.96% |
The required resistance ratio comes from rearranging η = RL / (RTh + RL) to RL = RTh · η / (1 − η). For the 12 V, 4 Ω source, a 90% efficient design uses RL = 36 Ω and delivers 3.24 W, which is 36% of the 9 W maximum.
The curve 4η(1 − η) is symmetric about η = 0.5. A design at 25% efficiency delivers the same fraction of Pmax as one at 75%, namely 75%. The two designs differ in cost: the 25% design wastes three quarters of the source's power. Operating below RTh is therefore almost never sensible, since you get less power and worse efficiency at the same time.
A pitfall: the Thevenin equivalent hides the real losses
The 50% figure describes the equivalent circuit. It is accurate for the equivalent only. A Thevenin equivalent is guaranteed to match the original circuit at the load terminals, meaning the same terminal voltage and current. It is not guaranteed to match the power dissipated inside the source network.
Take the circuit from the earlier worked example: a 24 V source with a 6 Ω series resistor, and a 3 Ω resistor from that node to ground. The load connects across the 3 Ω resistor. The Thevenin equivalent is 8 V in series with 2 Ω, so the matched load is 2 Ω and it receives 8 W. The equivalent claims 50% efficiency. Now compute the power the real 24 V source supplies.
v_s, r1, r2 = 24.0, 6.0, 3.0
r_load = 2.0 # matched load from the Thevenin equivalent
r_par = r2 * r_load / (r2 + r_load) # 3 ohm in parallel with the load
i_s = v_s / (r1 + r_par) # current drawn from the real source
v_node = i_s * r_par # voltage at the load terminals
p_source = v_s * i_s
p_load = v_node ** 2 / r_load
print(f"I_s={i_s:.4f} A P_source={p_source:.2f} W P_load={p_load:.2f} W")
print(f"real efficiency = {p_load / p_source:.0%}")
# Output:
# I_s=3.3333 A P_source=80.00 W P_load=8.00 W
# real efficiency = 10%The load still receives its 8 W, so the maximum-power result holds. The 24 V source supplies 80 W, though. The 6 Ω resistor dissipates 66.7 W and the 3 Ω resistor dissipates 5.3 W. The real efficiency is 10%, not 50%.
The cause is that the Thevenin procedure replaces the whole network, including the independent source, with a single source and a single resistor. The resistor R_Th = 2 Ω is the resistance seen from the terminals with the source turned off. It is not a physical component that carries the same current as the source. The equivalent's source current (2 A) differs from the real source current (3.33 A), so the equivalent's losses are not the real losses.
Use this rule:
- If the source really is a battery or generator with an internal series resistance, R_Th is a physical resistance and the 50% figure is the real efficiency.
- If the source side is a larger network that has been reduced, the 50% figure only describes the equivalent. Compute the real efficiency from the original circuit if it matters.
Choosing the design goal
Whether you want the matched load depends on what is scarce and what the load does with the power.
- Power delivery and distribution. Utilities and battery-powered systems cannot afford to waste half their energy. They keep R_L much larger than the source and line resistance, so efficiency is high. Operating at the matched point would double the fuel burned or halve the battery life for the same delivered energy.
- Signal sources with fixed resistance and little power. In a small-signal source such as a sensor or microphone, the total power is tiny and wasted heat does not matter. The aim is to extract the most signal power, so matching is appropriate. At radio frequencies, matching also avoids reflections, which the AC chapter covers briefly.
- Sources that can be damaged. A source with low internal resistance, such as a battery, can supply far more than the matched current if the load is small. With RL = RTh the battery heats its own internal resistance as much as the load. The source's rating, not the matching theorem, often sets the lower limit for R_L.
- Fixed power requirement. If the load must receive a specific power, choose the R_L that gives that power at the highest efficiency. Of the two resistances that give the same power, use the larger one.
The last point follows from the symmetry of Pload / Pmax = 4η(1 − η). Two values of RL deliver the same power below Pmax: one smaller and one larger than R_Th. In the 12 V, 4 Ω example, 2 Ω and 8 Ω both give 8 W. The 8 Ω choice is 67% efficient, while the 2 Ω choice is only 33% efficient.
Common errors
- Treating 50% as a property of the theorem for any circuit. It is the efficiency of the Thevenin equivalent. See the 10% example above.
- Assuming the maximum-power load also gives maximum efficiency. Efficiency has no interior maximum. It increases toward 100% as R_L grows.
- Using efficiency to find the matched load. Setting dη/dRL = 0 has no solution, because η = RL / (RTh + RL) is strictly increasing. Only the power curve has a peak.
- Forgetting the source power. Calculating P_load alone cannot tell you efficiency. You must also know what the source supplies, which for the reduced circuit means returning to the original network.
- Holding RL fixed while changing RTh and expecting the same rule. If the load is fixed and the source resistance is adjustable, the best choice for power is RTh = 0, not RTh = R_L. The next chapters cover that case.
Exercise
A battery has V_Th = 9 V and an internal resistance of 3 Ω. (a) What load resistance gives 90% efficiency, and what power does the load receive? (b) What fraction of the maximum power is that?
Show answer
(a) RL = RTh · η / (1 − η) = 3 × 0.9 / 0.1 = 27 Ω. The current is 9 / (3 + 27) = 0.3 A, so Pload = 0.3² × 27 = 2.43 W. (b) Pmax = 9² / (4 × 3) = 6.75 W, so the fraction is 2.43 / 6.75 = 0.36, which matches 4η(1 − η) = 4 × 0.9 × 0.1 = 0.36.
Exercise
A network with VTh = 10 V and RTh = 5 Ω is the Thevenin equivalent of a larger circuit. A 5 Ω load is connected. (a) What does the equivalent circuit give for the load power and the efficiency? (b) Why can't you conclude that the original circuit's source delivers exactly twice the load power?
Show answer
(a) I = 10 / 10 = 1 A, so Pload = 1² × 5 = 5 W. The equivalent's source supplies 10 W, so the efficiency is 50%. (b) The Thevenin equivalent matches the original only at the load terminals (same voltage, current and power in the load). The equivalent's RTh is the resistance seen with the sources off, not a physical series resistor carrying the real source current. The power the original source supplies depends on the internal structure, and it can be much larger than 10 W, as in the 24 V example where the real efficiency was 10%.