Inductance and the henry
This chapter assumes you know Ohm's law, Kirchhoff's laws, basic derivatives, and the passive sign convention. It also assumes you know that a coil of wire carrying current produces a magnetic field. Here you will learn what inductance measures, what sets its value, and how to read the unit.
From field to flux linkage
A current in a coil creates magnetic flux, written Φ, in webers (Wb). Each turn of the coil is threaded by this flux. If the coil has N turns and the same flux passes through every turn, the total flux linkage is:
λ = NΦ
Flux linkage is also measured in webers (strictly weber-turns). Doubling the current doubles the field, so in a linear magnetic material the flux linkage is proportional to the current. Inductance is the constant of proportionality:
λ = L i
So inductance L is the flux linkage produced per ampere of current. A larger L means the same current builds more magnetic field.
The henry
The unit of inductance is the henry (H). One henry is one weber-turn per ampere. Using the voltage law from later chapters, v = L di/dt, you can also say that 1 H is the inductance that produces 1 V when the current changes at 1 A/s.
One henry is large for most circuit parts. You will usually see these prefixes:
| Value | Typical use |
|---|---|
| 100 nH | PCB trace, RF circuits |
| 10 µH | Switching power supplies |
| 10 mH | Filters, small chokes |
| 1 H | Large power-supply chokes, relay coils |
What sets the inductance
For a long coil (a solenoid) with a uniform core, the inductance is:
L = μ N² A / ℓ
- μ is the permeability of the core material, in H/m.
- N is the number of turns.
- A is the cross-sectional area of the coil, in m².
- ℓ is the length of the coil, in m.
Three design rules follow from this formula.
- Inductance grows with the square of the turns. Doubling N quadruples L. One factor of N comes from more flux per ampere. The other comes from each turn linking that flux.
- A magnetic core raises μ. Air has μ₀ = 4π × 10⁻⁷ H/m. Iron and ferrite can multiply this by hundreds or thousands.
- A wider coil raises L, and a longer coil lowers it for the same number of turns.
import math
mu0 = 4 * math.pi * 1e-7 # permeability of free space, H/m
N = 200 # turns
A = 1e-4 # cross-sectional area, m^2 (1 cm^2)
length = 0.05 # coil length, m (5 cm)
for mu_r in (1, 1000): # air core, then a core with relative permeability 1000
L = mu_r * mu0 * N**2 * A / length
print(f"mu_r = {mu_r}: L = {L * 1000:.3f} mH")The air-core coil comes out near 0.1 mH. The same coil on a core with relative permeability 1000 gives about 100 mH, a thousand times more.
Common errors
- Treating L as a property of the current. L depends only on geometry and core material, not on how much current flows. This holds until the core saturates, which a later chapter covers.
- Forgetting that turns enter squared. Adding 10% more turns raises L by about 21%.
- Mixing units. Convert mH and µH to henries before using a formula. Convert cm to m before using the solenoid equation.
Exercise
A solenoid has 100 turns, a cross-section of 2 cm², and a length of 10 cm, wound on a core with relative permeability 500. Find its inductance. Then find the inductance if the turns are doubled to 200 with all else unchanged.
Show answer
A = 2×10⁻⁴ m², ℓ = 0.1 m, μ = 500 × 4π×10⁻⁷ ≈ 6.283×10⁻⁴ H/m. L = μN²A/ℓ = 6.283×10⁻⁴ × 10⁴ × 2×10⁻⁴ / 0.1 ≈ 12.6 mH. Doubling the turns multiplies L by 4, giving about 50.3 mH.