Sub topic 3
Faraday's law: why a changing current induces voltage
This chapter assumes you know Ohm's law, Kirchhoff's laws, basic derivatives, and the passive sign convention. It explains where the inductor equation comes from. You will not need it to use v = L di/dt later, but it explains why the equation has the sign and shape it does.
From changing current to induced voltage
A current in a coil creates a magnetic field. The field passes through the turns of the coil. The total amount of field linked with all the turns is called the flux linkage, written λ (lambda) and measured in weber-turns.
For a coil with N turns, where each turn is crossed by magnetic flux Φ, the flux linkage is:
λ = N Φ
Faraday's law says that a changing flux linkage induces a voltage across the coil:
v = dλ/dt = N dΦ/dt
A steady flux induces no voltage. Only a change in flux does. This is why an inductor behaves very differently at DC than during switching.
Linking flux to current
In a linear inductor, the flux linkage is proportional to the current:
λ = L i
The constant L is the inductance, in henries. Substituting into Faraday's law gives:
v = d(L i)/dt = L di/dt
This holds when L is constant. That means the core does not saturate and the coil does not change shape. The result is the voltage-current law that the rest of this tutorial uses.
Why the sign matters: Lenz's law
Lenz's law states that the induced voltage always acts to oppose the change in current that caused it. If the current tries to rise, the induced voltage pushes against the rise. If the current tries to fall, the induced voltage pushes to keep it going.
With the passive sign convention, the current enters the positive terminal of the voltage. The plus sign in v = L di/dt then already includes this opposing behavior. If you reverse the voltage reference, you must add a minus sign.
Worked example
A 10 mH inductor carries a current that rises from 0 to 2 A in 1 ms at a constant rate. Find the voltage across it.
The rate of change is di/dt = 2 A / 1 ms = 2000 A/s. Then:
v = L di/dt = 0.01 H × 2000 A/s = 20 V
The following code performs the same calculation.
L = 10e-3 # inductance in henries (10 mH)
di = 2.0 # current change in amperes
dt = 1e-3 # time interval in seconds (1 ms)
v = L * di / dt # voltage during a constant current ramp
print(v) # 20.0 voltsThe voltage stays at 20 V for the whole ramp because the slope of the current is constant. If the current stopped changing, the voltage would fall to zero, even though 2 A is still flowing.
Common errors
- Treating the voltage as proportional to current. It is proportional to the rate of change of current.
- Dropping the sign. With reversed references, v = −L di/dt.
- Applying v = L di/dt to a saturated core. Once the core saturates, L is no longer constant, and the simple form fails.
Exercise
A 50 mH inductor carries a current that falls steadily from 3 A to 1 A in 4 ms. Using the passive sign convention, what is the voltage across it, and what is its sign?
Show answer
The rate of change is di/dt = (1 − 3) A / 4 ms = −500 A/s. So v = L di/dt = 0.05 H × (−500 A/s) = −25 V. The voltage is negative, which means it opposes the fall in current, as Lenz's law requires.