Sub topic 15
Source transformation with independent and dependent sources
This chapter assumes you can write KCL and KVL equations, solve small linear systems, and read source symbols and polarities. Source transformation swaps a voltage source in series with a resistor for a current source in parallel with that resistor, or the reverse. The two versions look the same from the outside. This lets you collapse a network step by step and avoid solving large systems.
The equivalence
A voltage source Vs in series with a resistor R is equivalent to a current source Is = Vs/R in parallel with the same R. Going the other way, Vs = Is·R.
Orientation matters. The current source arrow points toward the terminal that the voltage source marks with +.
"Equivalent" means equivalent at the two terminals only. The load sees the same voltage and current either way. The power inside the pair can differ. With the terminals open, the voltage-source version dissipates nothing in R. The current-source version dissipates Is²R, because Is circulates through R.
Dependent sources transform the same way
A dependent source has a value set by a controlling variable elsewhere in the circuit. The same algebra applies, and the controlling expression just rides along:
- A dependent voltage source k·x in series with R becomes a dependent current source k·x/R in parallel with R.
- A dependent current source k·x in parallel with R becomes a dependent voltage source k·x·R in series with R.
Here x is the controlling variable and k is the gain. The units of k change in the transformation. A VCVS with a dimensionless gain becomes a VCCS whose gain is in siemens.
The rule that causes most errors
The controlling variable must still exist after the transformation. The transformation removes the series connection between the source and R, or the parallel connection. So any voltage or current you used as x may stop being available. Check three cases before transforming:
- If x is a voltage across a different part of the circuit, such as a node voltage, it survives. Transform freely.
- If x is the current through the resistor R that is part of the pair, it does not survive. That branch current is gone after the swap. Keep the original form, or first rewrite x in terms of a variable that remains.
- If x is the voltage across the pair's own terminals, it still exists, but the dependent source now feeds back on its own terminal. This is fine in a nodal equation but easy to mishandle by hand. Write the equation carefully.
When you cannot transform
- An ideal voltage source with no series resistance has no current-source equivalent. Dividing by R = 0 gives an infinite Is.
- An ideal current source with no parallel resistance has no voltage-source equivalent.
- A resistor in parallel with an ideal voltage source does not change the terminal voltage, so you can drop it for terminal analysis. It still carries current. A resistor in series with an ideal current source does not change the terminal current, so you can drop it for terminal analysis in the same way.
Worked example with a dependent source
Node a connects to ground through R3 = 2 kΩ. Two branches feed node a:
- Branch 1: a 10 V independent source in series with R1 = 1 kΩ. The + terminal faces node a.
- Branch 2: a dependent voltage source 0.5·vx in series with R2 = 1 kΩ. The + terminal faces node a, and vx is the voltage from node a to ground.
The controlling variable vx is a node voltage, so it survives both transformations (case 1 above).
Step 1: transform branch 1. Is = 10 V / 1 kΩ = 10 mA, flowing into node a, in parallel with 1 kΩ.
Step 2: transform branch 2. The dependent current is 0.5·vx / 1 kΩ = 0.5 mS · vx, flowing into node a, in parallel with 1 kΩ.
Step 3: write KCL at node a. Let v = vx. Sources entering equal conductances times v:
10 mA + 0.5 mS · v = v · (1/1 kΩ + 1/1 kΩ + 1/2 kΩ) = 2.5 mS · v
Move the dependent term to the right side: 10 mA = 2.0 mS · v, so v = 5 V.
Step 4: check against the original circuit.
- Branch 1 current into a: (10 − 5) V / 1 kΩ = 5 mA.
- Branch 2 current into a: (0.5·5 − 5) V / 1 kΩ = −2.5 mA.
- Load current: 5 V / 2 kΩ = 2.5 mA.
5 mA − 2.5 mA = 2.5 mA, so KCL holds.
Checking with SPICE
The original circuit uses an E element for the dependent voltage source:
* Original circuit with VCVS in branch 2
V1 n1 0 DC 10
R1 n1 a 1k
E1 n2 0 a 0 0.5
R2 n2 a 1k
R3 a 0 2k
.op
.endThe transformed circuit uses an I element and a G element. In SPICE, the current of I n+ n- flows from n+ through the source to n-. Writing 0 a therefore pushes current into node a.
* Transformed circuit: independent and dependent current sources
I1 0 a DC 10m
G1 0 a a 0 0.5m
R1 a 0 1k
R2 a 0 1k
R3 a 0 2k
.op
.endBoth netlists report v(a) = 5 V, matching the hand result.
Using transformation in a longer reduction
A typical strategy has four steps:
- Mark the controlling variables and decide which ones must be preserved.
- Transform every source-and-resistor pair that does not define a controlling variable, so each branch is a current source in parallel with a resistor.
- Combine parallel current sources by adding them, and combine parallel resistors. A dependent source and an independent source can be added if they share the same two nodes.
- Solve for the controlling variable first. Then substitute it back to find the other quantities.
For a circuit with several nodes, transformation usually ends in a nodal equation like the one above. It does not replace nodal analysis. It simplifies the circuit before you write it.
Common mistakes
| Mistake | Why it fails | Fix |
|---|---|---|
| Arrow points the wrong way | The current source then pushes against the original polarity | Arrow points toward the + marking of the voltage source |
| Transforming a source with no series R | Is = Vs/0 is undefined | Keep the ideal source and use a supernode or supermesh |
| Absorbing the resistor that defines ix | The controlling current no longer exists | Rewrite ix in terms of a surviving voltage first |
| Expecting equal internal power | Equivalence holds only at the terminals | Compute power in the original circuit |
| Forgetting the gain's units change | k·x/R has units of siemens times x | Recompute the units after transforming |
Exercise
A CCCS of value 2·ix sits in parallel with a 5 Ω resistor. The arrow points up, toward the top terminal, and ix is the current through a 4 Ω resistor elsewhere in the circuit. Transform it into a dependent voltage source with series resistance. Give the value, the series resistor, and the polarity. Say whether the transformation is safe.
Show answer
The voltage source value is 2·ix × 5 Ω = 10·ix volts, in series with 5 Ω. The + terminal is the top terminal, because the current arrow points toward it. The transformation is safe: ix flows in a different resistor, so the controlling variable survives. It would not be safe if ix were the current through the 5 Ω resistor itself.