Sub topic 14
Power balance when dependent sources are present
This chapter assumes you can write KCL and KVL equations, solve small linear systems, and use the passive sign convention (current enters the positive terminal, so p = v·i is absorbed power). It also assumes you already know the four controlled source types.
Why power balance matters
Tellegen's theorem says that in any lumped circuit the power delivered by all elements equals the power absorbed by all elements. Energy is conserved, so the sum of all element powers, with signs, is zero.
Power balance is the best check on a finished analysis. It also catches a mistake that is easy to make with dependent sources. A dependent source can deliver or absorb power just like an independent one, so leaving it out of the tally makes the books fail to balance.
The rule for any source
Every source, dependent or independent, obeys the same rule. Take its terminal voltage and its terminal current, and ignore what controls it. With the passive sign convention:
- p = v·i with current entering the + terminal: positive means absorbing, negative means delivering.
- If current leaves the + terminal, the source is delivering p = v·i.
The control variable only determines the value of the output. The power depends on the output voltage and output current, and both are found from the circuit.
| Situation | Current direction at the + terminal | Result |
|---|---|---|
| Source pushing current out of its + terminal | Leaves | Delivers v·i |
| Current forced into the + terminal | Enters | Absorbs v·i |
| Either case, computed with p = v·i (passive convention) | Enters | p > 0 absorbs, p < 0 delivers |
A dependent source is an active element. It can deliver power for one operating point and absorb it for another. For example, a dependent source whose controlling variable changes sign can flip its direction of energy flow.
Worked example with a CCCS
Consider this circuit:
- An independent source V1 = 12 V has its + terminal at node 1 and its − terminal at ground.
- R1 = 4 Ω connects node 1 to node 2. Its current i flows from node 1 to node 2.
- R2 = 4 Ω connects node 2 to ground.
- A current-controlled current source pushes 2i into node 2, drawing it from ground. The controlling variable is i, the current in R1, and the gain is 2.
Step 1: solve the circuit
Write KCL at node 2. The current i arrives through R1, 2i arrives from the source, and v2/4 leaves through R2:
i + 2i = v2/4
KVL across R1 gives v2 = 12 − 4i. Substitute:
3i = (12 − 4i)/4, so 12i = 12 − 4i, so i = 0.75 A.
Then v2 = 12 − 4(0.75) = 9 V. The current in R2 is 9/4 = 2.25 A. KCL checks: 0.75 + 1.5 = 2.25 A.
Step 2: compute every element's power
| Element | Voltage and current | Power | Role |
|---|---|---|---|
| V1 | 12 V, 0.75 A leaving + terminal | 9 W | Delivers |
| R1 | i²R = 0.75² · 4 | 2.25 W | Absorbs |
| R2 | v²/R = 9²/4 | 20.25 W | Absorbs |
| CCCS | 9 V across it, 1.5 A leaving its + terminal (node 2) | 13.5 W | Delivers |
The CCCS current of 2i = 1.5 A flows into node 2. Node 2 is at +9 V relative to ground, so the current leaves the source at its positive terminal. That makes it a delivering element.
Step 3: check the balance
- Delivered: 9 + 13.5 = 22.5 W
- Absorbed: 2.25 + 20.25 = 22.5 W
The totals match, so the solution is consistent.
Common errors
- Using the control variable in the power formula. The CCCS power is not 2i · i. It is the source's own voltage times its own output current: 9 V · 1.5 A.
- Treating the source voltage as known. A current source has whatever voltage the rest of the circuit imposes. Find it from node voltages first.
- Assuming dependent sources only absorb. In this example the CCCS delivers 13.5 W, more than half of the total supplied power.
- Mixing conventions. Pick one convention for the whole tally. Mixed conventions produce totals that differ by twice the wrong terms.
- Forgetting an element. A balance that fails by exactly one element's power usually means that element was skipped.
Checking with SPICE
SPICE can confirm the numbers. The 0 V source Vsense measures the current in R1, and F1 injects twice that current into node 2. In a SPICE current source, the current flows from the first node through the source to the second node. So F1 0 2 pushes current into node 2.
* Power balance example: CCCS with gain 2
V1 1 0 DC 12
Vsense 1 1a DC 0
R1 1a 2 4
F1 0 2 Vsense 2
R2 2 0 4
.op
.endExpect v(2) = 9 V and i(v1) = −0.75 A. The negative sign is SPICE's way of saying V1 delivers power: its current is measured entering the + terminal, which is the passive convention. You can then calculate each element's power as in the table above and compare it with the hand result.
Where the power comes from
A dependent source does not create energy out of nothing. In a real amplifier or transistor, the extra power comes from a supply that the simplified model leaves out. In the diagram-level model, the dependent source simply acts as the supply of that extra energy. That is why the balance must include it: the controlled source is hiding a power supply.
This also explains why a controlled source may deliver more power than the independent source that controls it. A CCCS with a gain above 1 amplifies the signal, and the difference is paid by a supply you cannot see in the model.
Summary
- Use the same p = v·i rule and sign convention for every element.
- A dependent source's power uses its own terminal voltage and current.
- The totals of delivered and absorbed power must be equal.
- A mismatch points to a sign error, a missing element, or a wrong control variable.
Exercise
In the worked example, change the CCCS gain from 2 to 4, so the source pushes 4i into node 2. Find i, v2, the power of every element, and show that the power balances.
Show answer
KCL at node 2: i + 4i = v2/4 with v2 = 12 − 4i. So 5i = (12 − 4i)/4, which gives 20i = 12 − 4i, so i = 0.5 A and v2 = 10 V. V1 delivers 12 · 0.5 = 6 W. R1 absorbs 0.5² · 4 = 1 W. R2 absorbs 10²/4 = 25 W. The CCCS current is 4i = 2 A and leaves its + terminal at node 2 (10 V), so it delivers 20 W. Delivered: 6 + 20 = 26 W. Absorbed: 1 + 25 = 26 W. The balance holds.
Exercise
A student finds that total delivered power is 22.5 W but total absorbed power is 9 W plus 2.25 W. Which element was probably left out, and what kind of mistake is this?
Show answer
The student probably counted only V1 as a source and left out the CCCS, so the delivered side shows 9 W of source power while R2's 20.25 W was dropped from the absorbed side. In either reading, an element was omitted from the tally. The rule is to list every element, including dependent sources, before summing.