Sub topic 11
Using a screw gauge for wire diameter and sheet thickness
This chapter assumes you can compute a screw gauge's least count (pitch divided by the number of circular scale divisions). It also assumes you can read the linear and circular scales and apply a signed zero correction. Here we put those skills to work on two standard measurements: the diameter of a wire and the thickness of a sheet.
Why the screw gauge suits these jobs
A wire or a thin sheet is only a fraction of a millimetre thick. A metre rule cannot resolve that, and a vernier calliper with a least count of 0.01 cm (0.1 mm) is too coarse. A screw gauge with a pitch of 0.5 mm and 50 circular divisions has a least count of 0.01 mm. That is ten times finer.
Measuring wire diameter
A wire is round, but it may be slightly flattened or uneven. One reading can therefore mislead you. Use this procedure:
- Close the gap and record the zero error, with its sign.
- Place the wire between the studs. Turn the screw by the ratchet head only, until it clicks. The ratchet limits the force, so the wire is not squeezed.
- Read the linear scale reading (LSR) and the circular scale reading (CSR).
- Rotate the wire by 90° and read again at the same spot. Two perpendicular readings take care of any flattening.
- Repeat at three or more places along the wire. This takes care of uneven thickness.
- Correct each reading for zero error, then take the mean.
The corrected diameter is:
diameter = LSR + CSR × LC − zero error
Measuring sheet thickness
A sheet is measured the same way, but the gap is closed across its two faces. Thickness can vary across a sheet, so take readings at several points, such as the corners and the centre. Keep the sheet flat and clean between the studs. Dust or a bent edge adds to the reading.
Worked example
A wire is measured with a screw gauge of pitch 0.5 mm and 50 circular divisions. With the gap closed, the zero of the circular scale sits 2 divisions below the reference line. This is a positive zero error of +0.02 mm. With the wire in place, the LSR is 2.0 mm and the CSR is 27.
def screw_gauge_reading(pitch_mm, circular_divisions, lsr_mm, csr, zero_error_mm=0.0):
least_count = pitch_mm / circular_divisions
observed = lsr_mm + csr * least_count
return observed - zero_error_mm
# Pitch 0.5 mm, 50 circular divisions, so LC = 0.01 mm
print(round(screw_gauge_reading(0.5, 50, 2.0, 27, zero_error_mm=0.02), 2))The observed reading is 2.0 + 27 × 0.01 = 2.27 mm. Subtracting the zero error gives 2.27 − 0.02 = 2.25 mm.
Common errors in practice
| Mistake | Effect | Fix |
|---|---|---|
| Tightening by the thimble, not the ratchet | Compresses the wire, so the reading is too small | Use the ratchet until it clicks |
| Ignoring zero error | Systematic error in every reading | Record it before and after the measurement |
| Reading at one spot only | A non-uniform wire gives a misleading value | Take several readings at different places and angles |
| Turning the screw in both directions while closing | Backlash error | Always approach the final reading in the same direction |
Exercise
A screw gauge has a pitch of 1 mm and 100 circular divisions. When the gap is closed, the circular scale reads 4 divisions past the reference line, with the zero of the circular scale below it in the sense of a positive zero error. A sheet gives LSR = 3 mm and CSR = 58. Find the corrected thickness.
Show answer
Least count = 1/100 = 0.01 mm. Zero error = +4 × 0.01 = +0.04 mm. Observed reading = 3 + 58 × 0.01 = 3.58 mm. Corrected thickness = 3.58 − 0.04 = 3.54 mm.