Sub topic 15
Meter Bridge Precautions and Sources of Error
This chapter assumes you know the Wheatstone bridge balance condition, the meter bridge circuit (wire, two gaps, jockey, galvanometer, resistance box) and the formula X = R(100 − l)/l. Here you will learn the precautions that keep the result reliable, and the errors that remain even when you follow them.
Why precautions matter
The formula assumes four things. The wire has uniform cross-section and resistance per unit length. The balance length l is measured from the correct end. The connections add no resistance. The wire's temperature stays constant. Each precaution protects one of these assumptions.
Standard precautions
- Clean, tight connections. Loose or oxidised contacts add unknown resistance to R or X. Rub the connecting ends with sandpaper and tighten all plugs and screws.
- Use thick copper strips and wires. This keeps connection resistance negligible compared with R and X.
- Tap the jockey, do not slide it. Pressing and dragging the jockey scrapes the wire and makes its cross-section uneven.
- Keep the current small and the circuit open when idle. Insert the plug key only while taking a reading. A steady current heats the wire, and resistance rises with temperature.
- Choose R close to X. Then the balance point falls near 50 cm, which is where the percentage error in l is smallest.
- Take readings with R and X interchanged. This reduces the effect of end errors.
- Check the null point. The galvanometer should show zero deflection, not a small steady deflection.
Why the balance point should be near the middle
Differentiating X = R(100 − l)/l shows that the fractional error in X is smallest when l is near 50 cm. Near the ends of the wire, a small error in l becomes a large error in X.
def fractional_error_in_x(l_cm, delta_l_cm=0.1):
# dX/X = delta_l * 100 / (l * (100 - l))
return delta_l_cm * 100 / (l_cm * (100 - l_cm))
for l in (10, 30, 50, 70, 90):
print(l, round(fractional_error_in_x(l) * 100, 3), "%")With an uncertainty of 0.1 cm, the error is 0.111 % at l = 10 cm and 0.04 % at l = 50 cm.
Sources of error
| Source | Type | Effect | Remedy |
|---|---|---|---|
| End errors (resistance of copper strips and contacts at the wire ends) | Systematic | Measured l differs from the true electrical length | Interchange R and X and average |
| Non-uniform wire | Systematic | Resistance is not proportional to length | Use a uniform wire; tap the jockey |
| Heating of the wire | Systematic | Resistance rises during the experiment | Use a low current, with the key open between readings |
| Parallax or poor reading of l | Random | Scatter in l | Read the scale from directly above and repeat |
| Poor galvanometer sensitivity | Random | The null point is uncertain | Use a more sensitive galvanometer and check for a sharp null |
Exercise
A meter bridge gives a balance point at l = 20 cm in the first reading. Why is it better to change R and take a new reading than to rely on this result, and what value of R would you aim for if X is about 4 times R?
Show answer
Near 20 cm, the fractional error in l (and so in X) is larger than near 50 cm. With R on the left, X = R(100 − l)/l, so a balance at 20 cm means X = 4R. To bring the balance point near 50 cm, X and R should be roughly equal, so choose R about 4 times larger, so that R is close to X.