Sub topic 11
Mutual Inductance
Prerequisites and the central idea
This chapter assumes that you know magnetic flux, Faraday’s law, Lenz’s law, basic circuits, derivatives, and self-inductance. Mutual inductance applies Faraday’s law to two nearby coils.
A current changing in coil 1 creates a changing magnetic field. Some of that field passes through coil 2, so the flux through coil 2 changes. Coil 2 then develops an induced emf, even though the coils are electrically separate.
The mutual inductance, written \(M\), measures how strongly current in one coil links magnetic flux to the other coil. Its SI unit is the henry (H), the same unit used for self-inductance.
From flux linkage to induced emf
Suppose coil 1 carries current \(I1\). The magnetic flux produced by coil 1 and linked with coil 2 is \(\Phi{21}\). If coil 2 has \(N_2\) turns, its flux linkage is
\[ \lambda{21}=N2\Phi_{21}. \]
For a linear magnetic material and fixed coil positions, flux linkage is proportional to current:
\[ \lambda{21}=M I1. \]
Applying Faraday’s law gives the voltage induced in coil 2:
\[ \mathcal{E}2=-\frac{d\lambda{21}}{dt} =-M\frac{dI_1}{dt}. \]
The minus sign expresses Lenz’s law. The induced voltage opposes the change that produced it.
The same relationship works in the reverse direction:
\[ \mathcal{E}1=-M\frac{dI2}{dt}. \]
For ordinary passive, linear magnetic systems, the same \(M\) describes both directions.
| Quantity | Meaning | Unit |
|---|---|---|
| \(M\) | Mutual inductance between two coils | H |
| \(I_1\) | Current in the source coil | A |
| \(\mathcal{E}_2\) | Voltage induced in the second coil | V |
What determines mutual inductance?
Mutual inductance increases when the coils have more turns, larger effective area, or a core that guides more magnetic flux through both coils. It decreases when the coils are separated or poorly aligned.
A useful relationship is
\[ M=k\sqrt{L1L2}, \]
where \(L1\) and \(L2\) are the self-inductances and \(k\) is the coupling coefficient. The value of \(k\) ranges from 0 to 1:
- \(k=0\): no shared magnetic flux.
- \(k=1\): ideal coupling, with all relevant flux shared.
- \(0<k<1\): partial coupling, as in most real devices.
Direction and the dot convention
The sign of mutual-inductance voltage depends on how each coil’s terminals are labeled. Circuit diagrams often mark one terminal of each coil with a dot.
If current enters the dotted terminal of coil 1 and increases, the induced voltage in coil 2 makes its dotted terminal positive relative to its undotted terminal. If the current decreases, the polarity reverses. If the reference current enters an undotted terminal, the sign changes.
This convention prevents a common error: calculating the correct magnitude but assigning the wrong polarity. Always identify the reference current direction and the voltage polarity before applying the minus sign.
Transformers as an application
An ideal transformer uses mutual inductance between two coils on a shared core. If the primary and secondary have \(N1\) and \(N2\) turns, respectively, their voltage magnitudes satisfy
\[ \frac{V2}{V1}=\frac{N2}{N1}. \]
A coil with more secondary turns produces a higher voltage. Real transformers lose energy through resistance, leakage flux, and heating, so their output power is slightly less than their input power.
Exercise
Two coils have mutual inductance 0.080 H. If the current in coil 1 increases at 5.0 A/s, what is the magnitude of the induced voltage in coil 2?
Show answer
Use |E2| = M|dI1/dt| = (0.080 H)(5.0 A/s) = 0.40 V. The polarity is determined by the coil dots and Lenz's law.