Sub topic 2
Magnetic Flux Through a Surface
This chapter assumes that you know vectors, dot products, magnetic fields, and the force on a moving charge or current-carrying wire. It also assumes basic circuit ideas, including current, voltage, and resistance.
What magnetic flux measures
Magnetic flux measures how much magnetic field passes through a surface. The surface might be a flat loop, a coil, or an imaginary boundary.
For a uniform magnetic field passing through a flat surface,
\[ \Phi_B = \mathbf{B}\cdot\mathbf{A} \]
The vector \(\mathbf{A}\) is the area vector. Its magnitude is the surface area \(A\), and its direction is perpendicular to the surface. Using the dot product gives
\[ \Phi_B = BA\cos\theta \]
Here, \(\theta\) is the angle between the magnetic field \(\mathbf{B}\) and the area vector \(\mathbf{A}\).
The SI unit of magnetic flux is the weber, written Wb. Since \(1\ \text{Wb}=1\ \text{T}\cdot\text{m}^2\), a field of 1 tesla through an area of 1 square meter produces 1 weber of flux when the field is perpendicular to the surface.
Orientation matters
The angle is measured from the area vector, not from the surface itself.
| Field direction relative to the area vector | Angle \(\theta\) | Flux |
|---|---|---|
| Same direction | \(0^\circ\) | \(BA\) |
| Parallel to the surface | \(90^\circ\) | \(0\) |
| Opposite direction | \(180^\circ\) | \(-BA\) |
When the field is perpendicular to the surface, it points along the area vector or directly opposite it. The flux magnitude is then largest. When the field runs along the surface, no field passes through the surface, so the flux is zero.
The sign of flux depends on the chosen direction of the area vector. For an open surface, either normal direction can be chosen. For a loop, the chosen normal is connected to a positive direction around the loop by the right-hand rule.
Worked example
A rectangular loop has area \(0.020\ \text{m}^2\). A uniform magnetic field has magnitude \(0.50\ \text{T}\), and the field makes an angle of \(60^\circ\) with the area vector.
\[ \Phi_B = BA\cos\theta \]
\[ \Phi_B=(0.50)(0.020)\cos(60^\circ) =0.0050\ \text{Wb} \]
The flux is \(5.0\times10^{-3}\ \text{Wb}\). If the area vector were reversed, the signed flux would be \(-5.0\times10^{-3}\ \text{Wb}\), but the flux magnitude would be unchanged.
Nonuniform fields and changing surfaces
If the magnetic field varies across the surface, divide the surface into small patches. The total flux is then written as
\[ \PhiB=\intS \mathbf{B}\cdot d\mathbf{A} \]
For each small patch, \(d\mathbf{A}\) points normal to that patch. This integral adds the signed contribution from every patch.
For a coil with \(N\) identical turns, each turn has its own flux. If the field and geometry are the same for every turn, the flux linkage is \(N\Phi_B\). Faraday’s law uses this linked flux when calculating the induced emf.
Exercise
A \(0.10\ \text{m}^2\) surface is in a \(0.80\ \text{T}\) magnetic field. The field makes \(30^\circ\) with the area vector. What is the magnetic flux?
Show answer
\(\Phi_B=BA\cos\theta=(0.80)(0.10)\cos(30^\circ)\approx0.069\ \text{Wb}\).