Sub topic 1
Magnetic flux and how it changes
Prerequisites
This chapter assumes you know the following:
- A magnetic field B is a vector, measured in tesla (T).
- The dot product of two vectors, and the sine and cosine of an angle.
- The idea of a rate of change, written as a simple derivative.
What magnetic flux measures
Magnetic flux is a measure of how much magnetic field passes through a surface. For a flat surface of area A in a uniform field B, the flux is the dot product of the field and the area vector:
Φ = B · A = B A cos θ
The area vector A points perpendicular (normal) to the surface, and its length equals the area. The angle θ is between B and this normal, not between B and the surface itself. The SI unit of flux is the weber (Wb), where 1 Wb = 1 T m².
For a coil of N turns, the same flux passes through each turn. The total flux linkage is N Φ.
How the angle changes the flux
| θ | cos θ | Flux | Situation |
|---|---|---|---|
| 0° | 1 | B A (maximum) | Field perpendicular to the surface |
| 60° | 0.5 | 0.5 B A | Field tilted from the normal |
| 90° | 0 | 0 | Field parallel to the surface |
| 180° | -1 | -B A | Field passes through in the opposite direction |
Flux is a scalar, but it has a sign. The sign depends on which side of the surface you call the "front". Once you choose the normal direction, keep it for the whole problem.
Three ways to change the flux
The flux Φ = B A cos θ depends on three quantities. Changing any one of them changes the flux, and this is the basis of electromagnetic induction.
Rotation is the case used in the AC generator, which a later chapter covers.
Worked example
A square loop of side 10 cm sits in a uniform field of 0.40 T. The normal to the loop makes an angle of 60° with the field. Find the flux. Then find the flux after the loop is turned so that its normal lines up with the field.
- Area: A = 0.10 × 0.10 = 0.010 m².
- At 60°: Φ = 0.40 × 0.010 × cos 60° = 0.40 × 0.010 × 0.5 = 2.0 × 10⁻³ Wb.
- At 0°: Φ = 0.40 × 0.010 × 1 = 4.0 × 10⁻³ Wb.
The change in flux is ΔΦ = 4.0 × 10⁻³ − 2.0 × 10⁻³ = 2.0 × 10⁻³ Wb.
Rate of change of flux
Induction depends on how fast the flux changes, not on the flux itself. The average rate of change is ΔΦ/Δt. The instantaneous rate is dΦ/dt. If the loop above is turned in 0.10 s, the average rate is 2.0 × 10⁻³ / 0.10 = 2.0 × 10⁻² Wb/s.
The next chapter shows that this rate gives the induced emf.
Common errors
- Using the angle between the field and the plane of the loop. If the problem gives that angle, the flux is B A sin of it.
- Forgetting the factor N when the question asks about flux linkage.
- Mixing units. Convert cm² to m² before you multiply. 1 cm² = 10⁻⁴ m².
- Assuming a constant flux means zero flux. A steady, nonzero flux induces nothing.
Exercise
A circular coil of 50 turns and radius 10 cm has its plane perpendicular to a uniform field of 0.20 T. The coil is rotated through 90° in 0.05 s. Find the flux through one turn at the start and the average rate of change of total flux linkage. Use π = 3.14.
Show answer
Area = π r² = 3.14 × (0.10)² = 3.14 × 10⁻² m². The plane is perpendicular to the field, so the normal is parallel to B and θ = 0°. Initial flux per turn = 0.20 × 3.14 × 10⁻² = 6.28 × 10⁻³ Wb. After a 90° turn the normal is perpendicular to B, so the flux is 0. The change in flux linkage is N ΔΦ = 50 × (0 − 6.28 × 10⁻³) = −0.314 Wb. The average rate is −0.314 / 0.05 = −6.28 Wb/s, so its magnitude is 6.28 Wb/s.