Sub topic 10
Conservation of power in a circuit
This chapter assumes you know the passive sign convention, the formula p = v·i, and how to read the sign of p as absorbing or delivering power. It also assumes Kirchhoff's laws and Ohm's law.
The principle
Energy cannot be created or destroyed inside an ideal circuit. Every joule an element delivers must be absorbed by some other element. Power is the rate of energy transfer, so the same holds for power at every instant.
If every element uses the passive sign convention, the powers of all elements sum to zero:
Σ p = Σ v·i = 0
Some terms are negative (elements delivering power) and some are positive (elements absorbing power). Equivalently, the total power delivered equals the total power absorbed.
Why the sum is zero
The result follows from Kirchhoff's laws alone. It does not depend on what the elements are, so it also holds for nonlinear and dependent elements. KVL makes the element voltages consistent, and KCL makes the currents consistent. Together they guarantee that the products v·i cancel when summed. This result is known as Tellegen's theorem.
The practical consequence is a check. If your solved voltages and currents give a nonzero sum, at least one value or sign is wrong.
Worked example
A 24 V source drives two series resistors, R1 = 6 Ω and R2 = 2 Ω.
- The current is i = 24 / (6 + 2) = 3 A.
- The resistor voltages are v1 = 3 × 6 = 18 V and v2 = 3 × 2 = 6 V.
- For the resistors, the current enters the + terminal, so the passive sign convention applies directly. p1 = 18 × 3 = 54 W and p2 = 6 × 3 = 18 W.
- The 3 A leaves the source's + terminal. The current entering that terminal is therefore −3 A, so p = 24 × (−3) = −72 W.
The sum is −72 + 54 + 18 = 0. The source delivers 72 W, and the resistors absorb 72 W in total.
import math
# (voltage in V, current in A entering the + terminal) for each element
elements = {
"source": (24.0, -3.0),
"R1": (18.0, 3.0),
"R2": (6.0, 3.0),
}
powers = {name: v * i for name, (v, i) in elements.items()}
for name, p in powers.items():
print(f"{name}: {p:+.1f} W")
delivered = -sum(p for p in powers.values() if p < 0)
absorbed = sum(p for p in powers.values() if p > 0)
print(f"delivered = {delivered:.1f} W, absorbed = {absorbed:.1f} W")
print("balanced:", math.isclose(sum(powers.values()), 0.0, abs_tol=1e-9))The output is:
source: -72.0 W
R1: +54.0 W
R2: +18.0 W
delivered = 72.0 W, absorbed = 72.0 W
balanced: TrueUse a tolerance such as abs_tol for the final test. With non-round values, floating-point rounding makes an exact comparison with zero unreliable.
Reading an unbalanced result
An unbalanced sum tells you something is wrong, but not what. Check these causes in order:
- A source current was given the wrong sign. This is the most common cause.
- An element used the wrong polarity, so its p has the wrong sign.
- An arithmetic error in a voltage or current. A wrong magnitude makes the sum nonzero by a different amount than a sign flip does.
- An element was left out of the sum. Include current sources and dependent sources.
A sign flip on one element of power magnitude P changes the sum by 2P. If the sum is off by exactly twice one element's power, that element is the likely culprit.
A zero sum does not prove the solution is correct. Two compensating errors can still cancel. Treat the power balance as a strong check, and confirm with KCL or KVL at a node or loop when the result matters.
Exercise
In a solved circuit, three elements have powers of +40 W, −100 W and +25 W under the passive sign convention. A fourth element completes the circuit. What is its power, and does it absorb or deliver?
Show answer
The sum must be zero, so p4 = −(40 − 100 + 25) = +35 W. The element absorbs 35 W. Check: 40 + 25 + 35 = 100 W absorbed, which equals the 100 W delivered.