Sub topic 13
A first look at average power in AC circuits
This chapter assumes you know the passive sign convention, p = v·i, and the basic sinusoid form A cos(ωt + θ). You should also be able to integrate simple trigonometric functions.
Why instantaneous power is not enough
In a sinusoidal circuit, voltage and current change sign every cycle, so p = v·i changes with time too. Instantaneous power can be positive at one moment and negative the next. The passive sign convention still applies at every instant: positive p means the element is absorbing energy, and negative p means it is returning energy to the circuit.
In practice you usually want one number that describes the energy flow over a whole cycle. That number is the average power.
Deriving the average power
Let the voltage and current of one element follow the passive sign convention:
- v(t) = Vm cos(ωt)
- i(t) = Im cos(ωt − φ)
Here φ is the angle by which the current lags the voltage. Multiplying and using the product-to-sum identity gives:
p(t) = (Vm Im / 2) [cos φ + cos(2ωt − φ)]
The first term is constant. The second term oscillates at twice the source frequency and averages to zero over a period T = 2π/ω. The average power is therefore:
P = (Vm Im / 2) cos φ = Vrms Irms cos φ
The rms values are Vrms = Vm/√2 and Irms = Im/√2. The factor cos φ is called the power factor.
Special cases
The phase angle φ fixes how the element behaves over a cycle.
| Element | φ | Average power P |
|---|---|---|
| Resistor | 0° | Vrms Irms = Irms² R = Vrms² / R |
| Ideal inductor | 90° | 0 |
| Ideal capacitor | −90° | 0 |
| General load | between −90° and 90° | Vrms Irms cos φ |
An ideal inductor or capacitor absorbs energy during one part of the cycle and returns exactly the same amount during another part. Its net energy over a period is zero, which matches the stored-energy formulas ½Li² and ½Cv² from earlier in this tutorial. Only resistance dissipates energy on average.
Checking the formula numerically
The script below averages v·i over exactly one period and compares the result with the formula.
import math
Vm = 10.0 # volts
Im = 2.0 # amperes
phi = math.radians(60.0) # current lags voltage by 60 degrees
N = 10000 # samples over one period
total = 0.0
for k in range(N):
wt = 2 * math.pi * k / N
v = Vm * math.cos(wt)
i = Im * math.cos(wt - phi)
total += v * i
p_numeric = total / N
p_formula = 0.5 * Vm * Im * math.cos(phi)
print(f"numeric average: {p_numeric:.3f} W")
print(f"formula: {p_formula:.3f} W")
# numeric average: 5.000 W
# formula: 5.000 WThe load absorbs 5 W on average. The product Vrms Irms is 10 VA, and the power factor cos 60° = 0.5 reduces it to 5 W.
Sign of the average
The sign rule from the earlier chapters carries over unchanged. If the average P is computed with v and i in passive sign convention and comes out positive, the element absorbs power on average. If it comes out negative, the element delivers power on average. In a balanced AC circuit the average powers of all elements still sum to zero, because the conservation of power holds at every instant and therefore also on average.
Exercise
A load has v(t) = 170 cos(ωt) V and i(t) = 4 cos(ωt + 30°) A, with current entering the + terminal. Find the average power and say whether the load absorbs or delivers power.
Show answer
The current lags the voltage by φ = 0° − 30° = −30°, so cos φ = 0.866. P = ½ · 170 · 4 · 0.866 ≈ 294 W. The value is positive under the passive sign convention, so the load absorbs about 294 W on average.
Exercise
Why does an ideal capacitor have zero average power even though its instantaneous power is not zero?
Show answer
For a capacitor, φ = −90°, so cos φ = 0. Its instantaneous power is a sinusoid at twice the source frequency with no constant term. The capacitor stores energy while p is positive and returns the same amount while p is negative, so the average over a period is zero.