How a Brushed DC Motor Responds to Voltage and Load
Prerequisites
This chapter assumes you know basic Arduino programming, Ohm’s law, and the difference between voltage, current, and power. You should also be able to read a simple wiring diagram and understand that a transistor can act as an electrical switch.
The motor’s working model
A brushed DC motor converts electrical power into rotation. Its two terminals receive a voltage. That voltage drives current through coils on the rotating part, called the armature. The coils create a magnetic field that interacts with permanent magnets or stationary coils in the motor.
A commutator and carbon brushes switch current between the armature coils as the shaft turns. This switching keeps the magnetic force pointed in a useful direction.
The motor’s behavior depends on four related quantities:
| Quantity | Meaning | Main effect |
|---|---|---|
| Voltage | Electrical push across the motor terminals | Sets possible speed |
| Current | Charge flowing through the coils | Produces torque and heat |
| Torque | Twisting force at the shaft | Moves the load |
| Speed | Shaft rotation rate | Creates back-EMF |
A motor does not draw one fixed current. The load and speed determine its current.
Voltage, speed, and back-EMF
When the motor spins, it acts partly like a generator. Its rotating coils produce a voltage that opposes the applied voltage. This opposing voltage is called back electromotive force, or back-EMF.
A useful simplified model is:
V_applied = I × R + V_back-EMF
Here, R is the motor winding resistance. As speed increases, back-EMF increases. Less voltage remains to push current through the winding, so current usually falls.
This explains why a lightly loaded motor can spin quickly while drawing modest current. Increasing the supply voltage usually allows a higher no-load speed, but exceeding the motor’s rated voltage can cause excessive speed, brush wear, and heat.
Load, torque, and stall current
A mechanical load resists rotation. The motor must produce more torque to maintain speed. In a brushed DC motor, torque is approximately proportional to current:
torque ≈ torque_constant × current
A heavier load slows the motor. Lower speed means less back-EMF, so more current flows. This extra current produces more torque, but it also produces more heat in the windings and driver.
A stall occurs when the shaft cannot turn. At stall, speed is zero and back-EMF is nearly zero. The current is then limited mostly by the winding resistance:
I_stall ≈ V_supply / R_winding
Stall current can be many times higher than the normal running current. A motor may survive a brief stall, but continuous stall can damage the motor or driver.
What this means for an H-bridge
An H-bridge changes the polarity applied to the motor, so it can reverse the magnetic force and shaft direction. The bridge does not remove the motor’s current demands. During startup or a stall, the bridge must handle the resulting high current without excessive voltage drop or overheating.
For a first test, run the motor with no mechanical load and use a current-limited supply if available. Measure running current, then compare it with the driver’s continuous and peak ratings. Do not hold the shaft still unless the motor and driver are explicitly rated for that condition.
Exercise
A 6 V motor has a winding resistance of 2 ohms. What approximate current flows at startup before the motor begins turning?
Show answer
Approximately 3 A, using I = V / R = 6 V / 2 ohms. This is close to the stall current and may last briefly during startup.