Sub topic 10
Current ratings, voltage drop, and heat
Assume you know basic Arduino programming, Ohm’s law, and how to read a simple wiring diagram. This chapter focuses on selecting a driver that can survive the motor’s current and dissipate its heat.
Motor current changes with load
A brushed DC motor does not draw one fixed current. It draws different amounts depending on its speed and mechanical load:
- No-load current is the small current needed to keep the unloaded motor spinning.
- Running current is the current under the normal mechanical load.
- Stall current is the current when the shaft cannot turn. This is usually the highest current.
At startup, the motor is stopped, so it initially draws close to its stall current. The same can happen when the motor pushes against an obstruction.
The driver must tolerate the stall current for the time your application may require. A rating based only on no-load or typical running current is unsafe.
Read driver ratings carefully
Driver datasheets often list continuous current, peak current, and conditions for those values. A peak rating may apply only for milliseconds or only when the chip is cool. A module’s advertised current may also assume a large heat sink or forced airflow.
| Value to check | Why it matters |
|---|---|
| Motor voltage range | The supply must stay within the driver and motor limits |
| Continuous output current | Must cover the expected loaded running current |
| Peak or stall current | Must cover startup and brief blocked-shaft events |
| Voltage drop or on-resistance | Determines lost voltage and heat |
| Thermal shutdown | Protects the chip, but does not replace correct sizing |
A practical design leaves margin. For example, if a motor normally draws 1.2 A but can stall at 4 A, a driver rated for only 1.5 A peak is a poor choice. Check whether the driver can handle 4 A for the expected stall duration, or add current limiting and mechanical protection.
Voltage drop becomes heat
Every driver loses some voltage while conducting. A bipolar driver may specify a saturation voltage for each conducting transistor. Since current passes through two sides of an H-bridge, the total motor voltage loss can be substantial.
A MOSFET driver usually specifies an on-resistance, written as \(R_{DS(on)}\). Estimate conduction loss with:
\[ P = I^2R \]
For two MOSFETs in the current path:
\[ P\text{driver} = I^2(R1 + R_2) \]
If each MOSFET is 0.15 ohms and the motor draws 2 A, the driver loses:
\[ 2^2(0.15 + 0.15) = 1.2\text{ W} \]
That heat must leave the package. At higher current, the loss rises with the square of current. Doubling current produces four times the conduction loss.
Check the complete power path
Measure voltage at the motor terminals while it is loaded, not only at the power supply. A thin wire, weak connector, protection diode, or driver drop can reduce motor voltage and torque.
Use short, suitable-gauge motor wires. Place a bulk capacitor near the driver’s motor supply pins, and follow the datasheet’s recommendations for smaller ceramic capacitors. Keep motor current out of the Arduino’s 5 V supply. Connect the Arduino ground and driver logic ground together so control signals have a shared reference.
Common errors
- Using the motor’s no-load current as the driver requirement.
- Treating a short-duration peak rating as a continuous rating.
- Ignoring startup and blocked-shaft conditions.
- Comparing module current numbers without checking cooling conditions.
- Powering the motor through the Arduino board or USB connection.
- Omitting local capacitors and then blaming resets on the code.
Exercise
A motor runs at 1 A but can draw 5 A at stall. Why is a 1.2 A driver unsafe?
Show answer
Startup or a blocked shaft can force about 5 A through the driver. The driver may overheat, enter thermal shutdown, or fail before the motor reaches speed.