Sub topic 11
Why Torque Drops with Speed and Steps Get Missed
Prerequisites
This chapter assumes you know how a stepper motor, driver, and separate motor power supply connect. You should also understand step angle, microstepping, STEP pulses, RPM, and basic voltage and current concepts.
The working model
A stepper motor moves when its driver energizes coils in a sequence. Each pulse advances the commanded position by one step or microstep. The driver assumes the rotor follows. In a typical open-loop system, no sensor confirms that movement occurred.
Torque is the turning force available at the shaft. A motor can hold its position with strong torque while stopped but have much less torque while rotating quickly.
Two effects cause the main speed-related loss:
- Coil inductance resists rapid changes in current. At higher step rates, the current has less time to reach its intended value.
- Back electromotive force, or back EMF, is a voltage produced by the spinning motor. It opposes the driver’s supply voltage and leaves less voltage available to push current into the coils.
A higher motor supply voltage helps current rise faster. It does not allow you to exceed the motor or driver’s voltage and current limits.
Torque, speed, and load
The motor must produce enough torque for both the mechanical load and the requested acceleration. The available torque usually falls as speed rises:
| Operating condition | Available torque | Typical risk |
|---|---|---|
| Holding position | Highest | Overheating if current stays on |
| Low-speed movement | High | Wiring or current-setting faults |
| High-speed movement | Lower | Stalling and missed steps |
| Sudden start at high speed | Too low for many loads | Immediate loss of position |
A motor may start successfully at 100 RPM but stall if commanded to start instantly at 600 RPM. The rotor cannot catch the rotating magnetic field quickly enough. The driver continues sending pulses, so the motor’s actual position falls behind the commanded position.
Missed steps and acceleration
A missed step occurs when the rotor does not reach the next commanded magnetic position before the following pulse arrives. The motor may vibrate, stop, or make a rough noise. Afterward, an open-loop controller usually has no way to know that its position is wrong.
Acceleration ramps reduce this risk. Instead of switching immediately to the final step rate, the controller begins slowly and increases the rate over time. It also decreases the rate before stopping or reversing.
// A simple linear acceleration ramp for a STEP/DIR driver.
const int STEP_PIN = 3;
const int DIR_PIN = 4;
void setup() {
pinMode(STEP_PIN, OUTPUT);
pinMode(DIR_PIN, OUTPUT);
digitalWrite(DIR_PIN, HIGH);
}
void loop() {
for (int delayUs = 3000; delayUs >= 1000; delayUs -= 10) {
digitalWrite(STEP_PIN, HIGH);
delayMicroseconds(3);
digitalWrite(STEP_PIN, LOW);
delayMicroseconds(delayUs);
}
delay(500);
}This example shortens the interval between pulses, so the motor speeds up gradually. A production design should also ramp down and use a motion library for accurate timing.
Diagnosing a stall
When a motor stalls, reduce speed and acceleration first. Then check that:
- The current limit matches the motor’s rated phase current.
- The supply voltage is suitable for the driver.
- The driver and motor have adequate cooling.
- The load is not binding or exceeding the motor’s torque.
- The coil pairs are identified correctly.
- STEP pulses meet the driver’s minimum high and low times.
Exercise
A 200-step motor uses 8x microstepping and receives 1,600 pulses per second. What speed should you expect?
Show answer
One revolution requires 200 × 8 = 1,600 pulses. Therefore, 1,600 pulses per second equals 60 revolutions per minute, or 60 RPM.