Sub topic 3
Reading a Stepper Motor's Ratings
Assume you know Arduino basics, Ohm’s law, and how to read a simple wiring diagram. This chapter focuses on interpreting a motor datasheet before choosing a driver or power supply.
A stepper motor rating describes the conditions under which the motor produces its specified performance. The most important values are step angle, rated phase current, phase resistance, inductance, holding torque, and sometimes a rated voltage.
Step angle and steps per revolution
The step angle is the angle moved by one full electrical step. Calculate full steps per revolution with:
\[ \text{steps per revolution}=\frac{360^\circ}{\text{step angle}} \]
For a motor with a 1.8° step angle:
\[ 360 \div 1.8=200\text{ full steps per revolution} \]
A 0.9° motor has 400 full steps per revolution. A smaller step angle usually gives finer positioning, but it does not automatically provide more torque or accuracy.
Microstepping divides each full step into smaller commanded positions. For example, 200 full steps with eighth-step microstepping gives 1,600 command steps per revolution. The motor still has 200 full-step magnetic positions, and microsteps have less available incremental torque than full steps.
Current, resistance, and voltage
Rated phase current is the current allowed in one winding when the motor reaches its specified temperature and performance. Set the driver’s current limit to this value, or lower it if the motor or driver becomes too hot.
Phase resistance is the resistance of one winding. A motor rated at 1.4 A with 2 Ω per phase has a winding voltage of:
\[ V=IR=1.4\times2=2.8\text{ V} \]
This value is useful for understanding heat, but it is not usually the recommended motor power-supply voltage. A modern chopper driver may use a 12 V or 24 V motor supply and regulate the winding current. Never connect the winding directly to an Arduino pin.
The motor’s electrical heating is approximately:
\[ P=I^2R \]
With both phases energized, the example motor dissipates about:
\[ 2\times1.4^2\times2=7.84\text{ W} \]
The actual temperature depends on the motor size, mounting, airflow, and driver behavior.
Torque and speed ratings
Holding torque is the torque required to move an energized motor away from its stationary position. It is measured while the motor is stopped, so it does not tell you the torque available at high speed.
Inductance resists rapid changes in winding current. High inductance generally makes it harder for current to rise quickly, reducing high-speed torque. A higher motor supply voltage can help a suitable current-regulating driver overcome this effect.
| Datasheet value | What to use it for |
|---|---|
| 1.8° step angle | Calculating 200 full steps per revolution |
| 1.4 A phase current | Setting the driver current limit |
| 2 Ω phase resistance | Estimating winding voltage and heat |
| 0.45 N·m holding torque | Comparing stationary load capacity |
Exercise
A motor has a 0.9° step angle and is configured for quarter-step microstepping. How many commanded steps produce one revolution?
Show answer
It has 360 ÷ 0.9 = 400 full steps per revolution. Quarter-step microstepping gives 400 × 4 = 1,600 commanded steps per revolution.