Sub topic 3
Control Limits Are Not Specification Limits
Assume you know the mean, range, and standard deviation, and that you understand a process produces measurements over time. This chapter separates two limits that often appear together but answer different questions.
- Control limits describe how a process has been behaving.
- Specification limits describe what a product or service must achieve.
Confusing them leads to incorrect conclusions and poor process decisions.
Control limits describe process behavior
A control chart usually has a center line and two control limits:
- The center line estimates the process average.
- The upper control limit, or UCL, marks an unusually high result.
- The lower control limit, or LCL, marks an unusually low result.
For a stable process, Shewhart limits are commonly set about three standard deviations from the center line. The limits estimate the range of routine, common-cause variation. They are calculated from process data, not from customer requirements.
A point outside a control limit is evidence that something unusual may have affected the process. The correct response is to investigate the process for a special cause, such as a new material, a machine adjustment, or a measurement problem.
A control limit does not state whether the output is acceptable to a customer.
Specification limits describe requirements
A specification is a requirement for an individual output. Specifications may come from a drawing, contract, regulation, design decision, or customer expectation.
- The upper specification limit, or USL, is the largest acceptable value.
- The lower specification limit, or LSL, is the smallest acceptable value.
Specification limits are fixed by the requirement. They do not move when the process average or variation changes.
A process can be stable but unable to meet specifications. For example, a filling process might consistently produce 510 milliliters when the target is 500 milliliters and the USL is 505 milliliters. Its control chart could show no special-cause signals, while every output fails the upper requirement.
A process can also be unstable while most individual values remain within specifications. An intermittent machine problem might produce occasional extreme values. The process needs investigation even if no product has yet exceeded a specification.
Compare the two kinds of limits
| Question | Control limits | Specification limits |
|---|---|---|
| What do they describe? | Observed process variation | Required product or service performance |
| Who determines them? | Process data and statistical methods | Customer, design, or regulatory requirements |
| Do they change with the process? | They may be recalculated between phases | Usually fixed |
| What does a violation mean? | Possible special cause | Nonconforming output |
| Main action | Investigate process behavior | Contain, rework, or assess the output |
The two pairs of limits can appear on the same chart, but they should remain conceptually separate.
Use the limits in the right order
First ask whether the process is stable. Use the control chart to check for points beyond limits and nonrandom patterns. If the process is unstable, capability calculations are misleading because the estimated average and variation do not represent one consistent process.
After removing understood special causes, establish a stable baseline. Then compare the stable process distribution with the specification limits. This comparison addresses capability: whether the process can meet requirements consistently.
For a roughly normal process, a simple capability measure is:
Cpk = the smaller of (USL minus the mean) divided by (3 times the standard deviation), and (the mean minus LSL) divided by (3 times the standard deviation).
A high Cpk requires both low variation and a mean positioned away from the nearest specification limit. Control limits alone cannot tell you Cpk, and Cpk alone cannot prove that the process is stable.
Example decision
Suppose a stable process has a mean of 100, a standard deviation of 1, an LSL of 96, and a USL of 103.
The upper side gives (103 − 100) ÷ 3 = 1.00. The lower side gives (100 − 96) ÷ 3 = 1.33. Therefore, Cpk is 1.00, limited by the upper specification. The process is centered closer to the USL, so reducing variation or moving the mean downward would improve capability.
Do not move control limits to make the chart look better. Do not change specifications because the process currently misses them without an approved engineering or customer decision.
Exercise
A stable process has all points inside its control limits, but several outputs exceed the USL. Is the process in statistical control, capable of meeting the requirement, both, or neither?
Show answer
It is in statistical control but is not capable of meeting the requirement consistently. Investigate capability and consider reducing variation or moving the process mean.