Sub topic 4
Cabling: twisted pair, coaxial, and fiber
This chapter assumes you know what a switch, router, and modem do (covered in the previous chapter) and can tell a wired port from a wireless connection. It covers the three cable families on the A+ Core 1 exam, how to tell them apart, and the errors technicians commonly make with them.
Why cabling still matters in a wireless chapter
Wi-Fi access points, routers, and switches all connect to the network through cables. A wireless network is only as fast and reliable as the wire behind it. An access point on a damaged or overlong cable will perform badly no matter how good its signal is.
Each cable type below suits a different job:
- Twisted pair connects devices inside a building.
- Coaxial carries cable-internet and TV signals into a building.
- Fiber carries light over long distances or at very high speed.
Twisted pair
Twisted pair cable holds four pairs of copper wires. Each pair is twisted around itself. The twist cancels much of the electromagnetic interference (EMI) that one wire would pick up from nearby wires and devices. Tighter twists reduce more interference.
UTP and STP
- UTP (unshielded twisted pair) has no metal shield. It is cheap, flexible, and the standard in homes and offices.
- STP (shielded twisted pair) wraps the pairs in foil or braided metal. It resists EMI better, so it suits places near motors, fluorescent lights, or heavy power cables. It costs more, is stiffer, and must be grounded properly to work as intended.
Categories
The category (Cat) number tells you the cable's rated speed and frequency. Higher categories use tighter twists and better construction.
| Category | Typical maximum speed | Rated frequency | Notes |
|---|---|---|---|
| Cat 5 | 100 Mbps | 100 MHz | Obsolete, but still found in old buildings |
| Cat 5e | 1 Gbps | 100 MHz | Common minimum for new gigabit runs |
| Cat 6 | 1 Gbps (10 Gbps up to about 55 m) | 250 MHz | Often has a plastic spline between the pairs |
| Cat 6a | 10 Gbps up to 100 m | 500 MHz | Thicker; often shielded |
| Cat 8 | 25 or 40 Gbps up to about 30 m | 2000 MHz | Meant for data centers |
Distance limit
Ethernet over twisted pair works up to 100 meters (328 feet) per segment. That includes the patch cables at both ends. Past that distance the signal weakens (attenuation) and errors rise. A switch or repeater can extend the run.
Connectors and wiring standards
Twisted pair ends in an RJ45 connector. It has eight pins and looks like a larger version of the RJ11 phone connector, which has fewer pins (usually two or four wires used).
Two wiring standards set the order of the colored wires:
- T568A
- T568B (the more common one in the United States)
A straight-through cable uses the same standard on both ends. It connects unlike devices, such as a computer to a switch. A crossover cable uses T568A on one end and T568B on the other. It was once needed to connect like devices directly, such as two computers. Modern ports use auto-MDI-X to detect and correct the wiring, so crossover cables are rarely needed now.
Plenum and riser ratings
Cable jackets are also rated for fire safety:
- Plenum cable has a fire-resistant jacket that gives off little toxic smoke. Building codes require it in air-handling spaces such as drop ceilings and ducts.
- PVC (riser) cable is cheaper and is used elsewhere, such as inside walls between floors.
Using PVC cable in a plenum space is a code violation, and exam questions often test it.
Coaxial cable
Coaxial (coax) cable has a copper center conductor, an insulating layer, a metal shield, and an outer jacket. All layers share the same central axis, hence the name. The shield protects the signal well, so coax works over longer runs than twisted pair.
Coax in a SOHO network usually links a cable modem to the wall outlet. The common connector is the F-type connector, which screws on. Coax grades you may see are:
- RG-6: used for cable TV and cable internet. It has better shielding and supports higher frequencies.
- RG-59: thinner and suited to short runs such as older analog video. It loses more signal over distance and is a poor choice for modern cable internet.
Older Ethernet networks used coax (10BASE2 and 10BASE5), but they are no longer in use.
Fiber-optic cable
Fiber-optic cable carries data as pulses of light through a glass (or sometimes plastic) core. It does not conduct electricity, so it is immune to EMI and does not create a spark risk. It also supports much longer distances and higher speeds than copper.
Single-mode and multimode
| Feature | Single-mode (SMF) | Multimode (MMF) |
|---|---|---|
| Core size | Very small (about 9 microns) | Larger (50 or 62.5 microns) |
| Light source | Laser | LED or low-cost laser |
| Typical distance | Many kilometers | Hundreds of meters |
| Cost | Higher equipment cost | Lower equipment cost |
| Typical use | Between buildings, ISP links | Inside a building or campus |
A larger core lets light take several paths, which spreads the signal over distance. That is why multimode reaches less far.
Fiber connectors
- LC (Lucent connector): small, square, with a push-pull latch. Common on modern equipment.
- SC (subscriber connector): square, push-pull. Common on older gear and in fiber-to-the-home installations.
- ST (straight tip): round, with a twist-lock bayonet fitting. Found on older multimode links.
Fiber cannot be bent sharply. A tight bend can break the glass or leak light, which causes signal loss. Never look into the end of a live fiber, because the light can damage your eyes even if you cannot see it.
Comparing the three types
Common errors and gotchas
- Exceeding 100 meters. A link that works at 90 m of cable can fail once patch cords push the total past 100 m.
- Mixing wire order within a pair. A cable that is wired in the wrong order may test for continuity but produces slow speeds or errors, because the twisted pairs are split. Always keep each pair together.
- Running data cable beside power lines. Parallel runs next to mains wiring or fluorescent fixtures induce interference. Cross power lines at right angles and keep distance, or use STP.
- Using the wrong coax. RG-59 on a cable-internet line can cause a weak signal and dropped connections.
- Over-bending or crushing cable. Sharp bends and tight cable ties damage twisted pair and break fiber.
- Plugging a phone cable into a network port. The RJ11 plug is narrower and can physically fit in an RJ45 jack, but it will not work and may bend the pins.
Tools you should recognize
- Cable tester: checks continuity and wiring order (pin-to-pin mapping) on twisted pair.
- Crimper: attaches an RJ45 connector to a cable.
- Punch-down tool: seats wires into a patch panel or keystone jack.
- Toner probe (tone generator): finds one cable among many.
- Loopback plug: tests whether a network port can send and receive.
Exam recap
- Twisted pair: 100 m limit, RJ45, Cat 5e through Cat 6a for gigabit and 10-gigabit use, T568A and T568B wiring.
- Coax: RG-6 with F-type connectors for cable internet.
- Fiber: single-mode for long distance, multimode for short, with LC, SC, and ST connectors.
- Plenum cable is required in air-handling spaces.
Exercise
A technician runs 85 m of Cat 6a to a ceiling-mounted access point, then adds a 10 m patch cable at the switch and a 10 m cable at the access point. The link is unreliable. What is the likely cause, and what are two fixes?
Show answer
The total length is 105 m, which exceeds the 100 m twisted-pair limit, so the signal weakens and errors occur. Fixes: shorten the patch cables so the total stays within 100 m, or add a switch or repeater partway along the run. Using fiber for the long segment would also work.
Exercise
Which cable type and connector would you expect between a cable modem and the wall outlet, and why is RG-59 a poor substitute?
Show answer
Coaxial cable with an F-type connector, usually RG-6. RG-59 has thinner shielding and loses more signal at the higher frequencies that cable internet uses, so it can cause a weak signal and dropped connections.
Exercise
You must connect two buildings 800 m apart and avoid any electrical interference between them. Which cable type and mode should you choose?
Show answer
Single-mode fiber. Twisted pair stops at 100 m, multimode typically reaches only hundreds of meters, and fiber does not carry electricity or pick up EMI.