Sub topic 8
What a Load Does to a Voltage Divider
This chapter assumes you already know Ohm's law, the series and parallel resistance formulas, and the unloaded voltage divider rule, Vout = Vin × R2 / (R1 + R2). The rule describes a divider with nothing attached to its output. Real dividers feed something: an ADC pin, an amplifier input, a relay coil, a meter. This chapter shows how that attachment changes the output and how to predict the change.
Why the unloaded formula stops being true
The unloaded formula assumes R1 and R2 carry the same current. That holds only if nothing else draws current from the output node. A load connected from the output node to ground gives the current a second path. Kirchhoff's current law at that node now reads:
I(R1) = I(R2) + I(load)
R1 carries more current than before, so it drops more voltage. Whatever R1 drops, the output loses. The output therefore falls below the unloaded value.
The working model: R2 in parallel with the load
The load RL sits across R2, because both connect from the output node to ground. They share one voltage, so they are in parallel. Replace R2 with its parallel combination with RL and apply the ordinary divider rule:
R2eff = R2 × RL / (R2 + RL)
Vout = Vin × R2eff / (R1 + R2eff)
Worked example
Take Vin = 12 V, R1 = 10 kΩ, R2 = 5 kΩ. Unloaded, the output is 12 × 5k / 15k = 4 V. Now connect a 10 kΩ load.
- R2eff = 5k × 10k / 15k = 3.333 kΩ.
- Total resistance seen by the source = 10k + 3.333k = 13.333 kΩ.
- Source current = 12 V / 13.333 kΩ = 0.9 mA.
- Vout = 0.9 mA × 3.333 kΩ = 3.0 V.
Check the currents against Kirchhoff's current law. R2 carries 3 V / 5 kΩ = 0.6 mA. The load carries 3 V / 10 kΩ = 0.3 mA. The sum, 0.9 mA, equals the current through R1. The unloaded circuit drew only 0.8 mA, and the extra 0.1 mA through R1 is what pulled the output down by a full volt.
def parallel(ra, rb):
return ra * rb / (ra + rb)
def loaded_divider_vout(vin, r1, r2, rl):
"""Divider with a load rl connected across r2."""
r2_eff = parallel(r2, rl)
return vin * r2_eff / (r1 + r2_eff)
print(loaded_divider_vout(12.0, 10_000, 5_000, 10_000)) # 3.0 voltsA closed form for the loaded output
Substituting R2eff and clearing the fractions gives one expression:
Vout = Vin × R2 × RL / (R1 × R2 + R1 × RL + R2 × RL)
For the example, the numerator is 12 × 5k × 10k = 600 × 10⁶ and the denominator is 50 × 10⁶ + 100 × 10⁶ + 50 × 10⁶ = 200 × 10⁶. The ratio is 3 V, matching the step-by-step result.
A more useful form compares the loaded output with the unloaded one:
Vloaded / Vunloaded = RL / (RL + Rth), where Rth = R1 × R2 / (R1 + R2)
Rth is R1 and R2 in parallel. This is the output resistance of the divider, and the next chapter explains why it works as a Thevenin equivalent. For now, treat it as a number you can compute. Here Rth = 3.333 kΩ, and RL / (RL + Rth) = 10k / 13.333k = 0.75. So the loaded output is 75% of 4 V, which is 3 V.
This form gives a quick error estimate. When RL is much larger than Rth, the fractional drop is about Rth / RL. To keep the loaded output within 1% of the unloaded value, you need RL ≥ 99 × Rth, so in practice about 100 × Rth.
How the output falls as the load gets heavier
A heavier load means a smaller RL. This script sweeps RL for the same divider and reports the error against the unloaded 4 V.
def parallel(ra, rb):
return ra * rb / (ra + rb)
def loaded_divider_vout(vin, r1, r2, rl):
r2_eff = parallel(r2, rl)
return vin * r2_eff / (r1 + r2_eff)
VIN, R1, R2 = 12.0, 10_000, 5_000
unloaded = VIN * R2 / (R1 + R2)
for rl in [500_000, 50_000, 10_000, 5_000, 1_000]:
v = loaded_divider_vout(VIN, R1, R2, rl)
err = (v - unloaded) / unloaded * 100
print(f"{rl:>8} ohm {v:6.3f} V {err:7.2f} %")The output is:
500000 ohm 3.974 V -0.66 %
50000 ohm 3.750 V -6.25 %
10000 ohm 3.000 V -25.00 %
5000 ohm 2.400 V -40.00 %
1000 ohm 0.923 V -76.92 %| Load RL | Loaded Vout | Error vs 4 V |
|---|---|---|
| Open (infinite) | 4.000 V | 0% |
| 500 kΩ | 3.974 V | -0.66% |
| 50 kΩ | 3.750 V | -6.25% |
| 10 kΩ | 3.000 V | -25% |
| 5 kΩ | 2.400 V | -40% |
| 1 kΩ | 0.923 V | -76.9% |
| Short (0 Ω) | 0 V | -100% |
Two patterns stand out. A load ten times larger than R2 (50 kΩ here) still costs 6.25%, because the error depends on Rth, which is 3.33 kΩ, not on R2 alone. And the error grows quickly once RL falls to the same order as R1 and R2.
Edge cases
Open and shorted loads
With RL → ∞ the load draws no current and the unloaded formula applies exactly. With RL = 0 the output node is tied to ground, so Vout = 0 and all of Vin falls across R1. The source current is then Vin / R1, the largest the divider can draw.
A load across R1 instead of R2
A load from the output node to the supply side, not to ground, lies in parallel with R1. It shrinks the top resistor, so the output rises. The model is the same, with the parallel combination substituted into the other position: Vout = Vin × R2 / (R2 + R1eff), where R1eff = R1 × RL / (R1 + RL). Always check which two nodes the load actually connects.
The voltmeter is a load too
A digital multimeter has an input resistance, commonly 10 MΩ. Measure the midpoint of a divider with R1 = R2 = 1 MΩ from a 10 V source. The expected output is 5 V. The meter in parallel with R2 gives 1M × 10M / 11M = 909 kΩ, so the reading is 10 × 909k / (1M + 909k) = 4.76 V. The meter disturbs the circuit it measures, which matters in any high-resistance divider.
Common errors
- Using the unloaded formula with a load attached. The result is always too high.
- Adding the load in series instead of in parallel. A load from the output node to ground is parallel to R2.
- Taking the load's resistance from a datasheet "typical" value and ignoring that it can vary. An input that draws more current at some voltages changes the divider ratio as the signal moves.
- Judging the load as "large" by comparing RL to R2 only. Compare it to Rth, which includes R1.
- Forgetting that a source with its own output resistance adds to R1 and shifts the ratio.
Effects beyond the output voltage
Loading also changes the current and power in the circuit. In the worked example, the source current rose from 0.8 mA to 0.9 mA. Power in R1 rose from (0.8 mA)² × 10 kΩ = 6.4 mW to (0.9 mA)² × 10 kΩ = 8.1 mW. With a very small RL, R1 can carry Vin / R1 and dissipate Vin² / R1. Check R1's power rating against the worst-case load, not only the nominal one.
Exercise
A 9 V source feeds a divider with R1 = 2 kΩ and R2 = 2 kΩ. A 2 kΩ load is connected across R2. What is the output voltage, and how much current does the source supply?
Show answer
R2 in parallel with RL = 2k × 2k / 4k = 1 kΩ. Vout = 9 × 1k / (2k + 1k) = 3 V. Source current = 9 V / 3 kΩ = 3 mA. The unloaded output would have been 4.5 V, so the load costs 1.5 V.
Exercise
A 5 V source drives a divider with R1 = R2 = 10 kΩ. The unloaded output is 2.5 V. What is the smallest load resistance that keeps the output within 1% of 2.5 V?
Show answer
Rth = 10k || 10k = 5 kΩ. Require RL / (RL + Rth) ≥ 0.99, so RL ≥ 99 × Rth = 495 kΩ. Check: 495k || 10k = 9.80 kΩ, and Vout = 5 × 9.80k / 19.80k = 2.475 V, which is 1% below 2.5 V.
Exercise
You measure the midpoint of a divider with R1 = R2 = 100 kΩ from a 10 V supply using a meter with 10 MΩ input resistance. What does the meter read, and what is the error?
Show answer
The meter in parallel with R2 gives 100k × 10M / 10.1M = 99.01 kΩ. Reading = 10 × 99.01k / (100k + 99.01k) = 4.975 V. The true unloaded value is 5 V, so the error is about -0.5%.