Using Dimensional Analysis and Measurement Errors
Assume basic algebra, powers, percentages, and familiarity with length, mass, time, velocity, and force.
Checking, deriving, and converting with dimensions
A dimension describes the physical nature of a quantity using base quantities. For example, velocity has dimension \([LT^{-1}]\), and force has dimension \([MLT^{-2}]\). The principle of homogeneity states that every term added or equated must have the same dimensions.
For example, in \(s = ut + \frac12at^2\):
- \([s] = L\)
- \([ut] = [LT^{-1}][T] = L\)
- \([at^2] = [LT^{-2}][T^2] = L\)
Therefore, the equation is dimensionally consistent.
Dimensions can also derive a relation. Suppose the period \(T\) of a pendulum depends on length \(L\) and gravitational acceleration \(g\):
\[ T = kL^a g^b \]
Using \([T]=T\), \([L]=L\), and \([g]=LT^{-2}\),
\[ T = L^{a+b}T^{-2b} \]
Comparing powers gives \(a=\frac12\) and \(b=-\frac12\). Hence,
\[ T=k\sqrt{\frac{L}{g}} \]
The constant \(k\) cannot be found by dimensional analysis alone.
# Dimensions use exponent tuples (M, L, T)
def multiply(a, b):
return tuple(x + y for x, y in zip(a, b))
mass = (1, 0, 0)
velocity = (0, 1, -1)
time = (0, 0, 1)
acceleration = multiply(velocity, (0, 0, -1))
force = multiply(mass, acceleration)
print(acceleration, force)For unit conversion, use the base-unit definitions. Since \(1\,\mathrm{N}=1\,\mathrm{kg\,m\,s^{-2}}\), and \(1\,\mathrm{kg}=10^3\,\mathrm{g}\), \(1\,\mathrm{m}=10^2\,\mathrm{cm}\), we get \(1\,\mathrm{N}=10^5\) dyne.
Limitations of dimensional analysis
It cannot determine numerical constants such as \(2\) or \(\pi\). It cannot distinguish quantities with identical dimensions, such as work and torque. It also cannot derive relations involving trigonometric, exponential, or logarithmic functions, and it does not handle vector direction.
Accuracy, precision, and errors
Accuracy is closeness to the true value. Precision is closeness among repeated readings. A precise instrument may still be inaccurate if it has a calibration error.
| Error type | Main cause | Example |
|---|---|---|
| Systematic | Consistent bias | Zero error |
| Random | Unpredictable variation | Reaction-time changes |
| Gross | Human mistake | Reading the wrong scale |
Repeat measurements and average them to reduce random error. Systematic error requires calibration or correction.
Vernier calliper and screw gauge
For a vernier calliper,
\[ \text{least count} = 1\text{ MSD} - 1\text{ VSD} \]
The reading is:
\[ \text{MSR} + (\text{coinciding vernier division})(\text{least count}) \]
Subtract a positive zero error from this reading. For a screw gauge,
\[ \text{least count}=\frac{\text{pitch}}{\text{number of circular divisions}} \]
The same zero-error correction applies.
Exercise
A vernier calliper has a least count of 0.1 mm. Its observed reading is 24.6 mm and its positive zero error is 0.2 mm. Find the corrected reading.
Show answer
Corrected reading = 24.6 - 0.2 = 24.4 mm.