Sub topic 12
Systematic, random, and gross errors
This chapter assumes you can read a vernier caliper and a screw gauge, find a least count, and apply a zero correction. It also assumes you know what a mean is. Here you learn to classify what goes wrong in a measurement, because the class decides how to fix it. The next chapter turns these ideas into numbers (absolute, relative, and percentage error).
What "error" means in physics
An error is the difference between a measured value and the true value. It is not a mistake in the everyday sense. Even a careful experimenter with a good instrument gets errors. The true value is usually unknown, so we estimate the size of the error from the instrument, the method, and the spread of repeated readings.
Errors fall into three classes.
| Class | Direction | Repeating the reading | Typical fix |
|---|---|---|---|
| Systematic | Always the same way, or in a predictable pattern | Does not reveal it | Find the cause and correct for it |
| Random | Sometimes high, sometimes low | Scatter shows it | Take many readings and average |
| Gross | A single large slip | One reading stands far from the rest | Discard it and repeat the measurement |
Systematic errors
A systematic error pushes every reading in the same direction, or by an amount that follows a rule. Repeating the measurement gives the same bias, so averaging does not remove it. Because the readings agree with each other, a systematic error can go unnoticed.
Common sources:
- Instrumental errors. A zero error on a vernier caliper or screw gauge. A stretched metre scale. A stopwatch that runs fast. A badly calibrated ammeter.
- Imperfection in the method. Ignoring air resistance in a free-fall experiment. Measuring the length of a pendulum to the top of the bob instead of its centre. Using a thermometer that takes heat from a small sample.
- Environmental errors. A metal scale that expands on a hot day. Draughts that affect a sensitive balance.
- Personal errors. A habit of reading a scale from one side. A consistent delay in starting the stopwatch.
Parallax is a good example of how the label depends on behaviour. If you always look from the left, the error is systematic. If your viewing angle changes randomly from reading to reading, the same effect behaves as a random error.
Correcting systematic errors
A systematic error is removed by identifying it, not by repeating the measurement. The usual tools are:
- Measure and apply the zero correction: corrected reading = observed reading − zero error.
- Calibrate the instrument against a standard.
- Improve the method, for example by using a heavier bob to reduce the relative effect of air drag.
- Measure the same quantity with a different instrument or method and compare.
Corrections work in both directions. If a caliper has a negative zero error of −0.03 cm, the correction is to add 0.03 cm to every reading.
Random errors
A random error comes from many small, uncontrolled effects: slight changes in reaction time, small vibrations, fluctuating temperature, and the experimenter's judgement when a mark lies between two divisions. Each reading is a little high or a little low, with no pattern from one reading to the next.
For random errors, the readings are spread about a centre. Small deviations are more common than large ones, and positive and negative deviations are about equally likely. This is why averaging helps. Positive and negative deviations partly cancel in the mean.
Averaging has limits:
- The reduction is slow. The random uncertainty of the mean falls roughly as 1/√n, so going from 4 readings to 16 only halves it.
- Averaging cannot go below the resolution of the instrument. A stopwatch with a least count of 0.1 s gives limited information however many readings you take.
- Averaging does nothing to a systematic error. A mean of a thousand readings from a caliper with a zero error still carries that zero error.
A useful rule: if repeated readings are identical, the scatter is smaller than the least count, and the least count is the dominant uncertainty. Many JEE problems take the least count as the uncertainty in a single reading for this reason.
Gross errors
A gross error is a large, avoidable slip. Examples include reading 7 as 1 on a scale, writing down 12.5 instead of 15.2, counting 21 oscillations instead of 20, or connecting a circuit wrongly. A gross error is caused by carelessness or a faulty setup, not by the nature of the measurement.
Gross errors are dealt with differently from the other two:
- They are not averaged in. One large outlier shifts the mean noticeably and inflates the spread.
- They are not corrected with a formula. You discard the reading and, if possible, repeat the measurement.
- They are prevented by good habits: recording readings immediately, reading twice, and checking that each value is plausible.
Seeing the three types in numbers
The first program measures a 5.24 cm object with a caliper that has a zero error of +0.02 cm. The readings agree closely, which suggests good precision, but they are all shifted. Averaging does not fix the shift, while the zero correction does.
import statistics
zero_error = 0.02 # cm, from the closed-jaw reading
readings = [5.26, 5.27, 5.25, 5.26, 5.27, 5.26] # cm, observed
mean = statistics.mean(readings)
scatter = statistics.mean(abs(r - mean) for r in readings)
print(round(mean, 2)) # 5.26: biased by the zero error
print(round(scatter, 2)) # 0.01: small random scatter
print(round(mean - zero_error, 2)) # 5.24: corrected valueThe scatter of about 0.01 cm is the random part. The offset of 0.02 cm is the systematic part. Only the second program step, the subtraction, removes the offset.
The second program shows a gross error. Five readings of the time for 20 oscillations agree, and a sixth is far off, perhaps because the stopwatch was started late. The program flags readings far from the median, using the median absolute deviation (MAD) as the scale. Using the median means the outlier does not distort the reference.
import statistics
times = [40.2, 40.4, 40.3, 40.1, 40.3, 44.3] # s for 20 oscillations
median = statistics.median(times)
mad = statistics.median(abs(t - median) for t in times)
kept = [t for t in times if abs(t - median) <= 5 * mad]
print(round(statistics.mean(times), 2)) # 40.93: pulled up by the outlier
print(kept) # [40.2, 40.4, 40.3, 40.1, 40.3]
mean_kept = statistics.mean(kept)
spread = statistics.mean(abs(t - mean_kept) for t in kept)
print(round(mean_kept, 2), round(spread, 2)) # 40.26 0.09The single bad reading raises the mean by about 0.7 s. After it is removed, the mean is 40.26 s with a mean absolute deviation of 0.09 s. The factor of 5 in the code is a choice made for this example, not a universal law. In a lab, state your rejection rule before you look at the data.
Accuracy and precision
These two words describe different things, and they map onto the error types.
- Accuracy is how close a result is to the true value. Systematic errors reduce accuracy.
- Precision is how close repeated readings are to each other. Random errors reduce precision.
A set of readings can be precise but inaccurate, as with the caliper above. It can be accurate on average but imprecise, when the readings scatter widely around the true value. The best experiments are both, and you need to fix the systematic errors and reduce the random ones to get there.
Common mistakes
- Treating a zero error as random. It is the same for every reading, so it is systematic and must be subtracted, not averaged out.
- Taking more readings to fix a biased instrument. This only makes you more confident in a wrong value.
- Averaging in an obvious blunder and then reporting the spread as "random error". The spread then measures your slip, not the experiment.
- Confusing the sign convention. For a positive zero error, subtract it. For a negative zero error, add its magnitude.
- Calling an error "human error" in a classification question. Decide whether it acts the same way each time (systematic), varies unpredictably (random), or is a one-off slip (gross).
Classification table for typical cases
| Situation | Class | Reason |
|---|---|---|
| Screw gauge shows 0.03 mm with the studs closed | Systematic | The same offset enters every reading |
| Stopwatch started a little early or late, varying each time | Random | Reaction time varies unpredictably |
| Writing 3.45 cm as 4.35 cm | Gross | A single large recording slip |
| A metre scale that has expanded in warm weather | Systematic | Every length reads low by the same fraction |
| Pendulum length measured to the top of the bob | Systematic | A consistent flaw in the method |
| Reading a pointer between two marks | Random | The judgement varies from reading to reading |
Exercise
A student measures the diameter of a wire with a screw gauge six times and gets 1.52, 1.53, 1.52, 1.54, 1.53 and 1.53 mm. The screw gauge has a zero error of −0.04 mm. (a) Which part of the total error is systematic and which is random? (b) What is the corrected mean diameter?
Show answer
(a) The zero error of −0.04 mm is systematic, because it affects every reading the same way. The small scatter of about 0.01 mm among the readings is random. (b) The mean of the observed readings is 9.17/6 = 1.528 mm, which is about 1.53 mm. For a negative zero error, add its magnitude: 1.53 + 0.04 = 1.57 mm.
Exercise
In an experiment on the time for 20 oscillations, the readings are 36.2 s, 36.4 s, 36.3 s, 36.2 s and 63.1 s. Classify the 63.1 s reading and say what you should do with it.
Show answer
It is a gross error, probably a transposition of digits (36.1 s written as 63.1 s) or a counting slip. It lies far from the other readings, so it should be rejected, with a note of the reason, and the measurement repeated if possible. The mean of the remaining four readings is (36.2 + 36.4 + 36.3 + 36.2)/4 = 36.275 s, about 36.3 s.
Exercise
Explain why increasing the number of readings from 10 to 1000 improves precision but does not improve accuracy when an ammeter is miscalibrated.
Show answer
More readings average out random scatter, so the mean becomes more precise, with uncertainty falling roughly as 1/√n. A miscalibration shifts every reading by the same amount or factor, so it is a systematic error. The mean carries the same shift however many readings are taken, so accuracy does not improve unless the ammeter is recalibrated or corrected.