Sub topic 13
Thermal Resistance and Rods in Series and Parallel
This chapter assumes you know conduction, Q/t = kA(T₁ − T₂)/L, and basic algebra with SI units. It also assumes you know how resistors combine in an electric circuit.
The electrical analogy
Rewrite the conduction law as a heat current P = Q/t:
P = (T₁ − T₂) / R, where R = L / (kA)
R is the thermal resistance, in K/W. The mapping to circuits is direct.
| Electrical | Thermal |
|---|---|
| Current I | Heat current P (W) |
| Potential difference V | Temperature difference ΔT |
| Resistance R = ρL/A | Resistance R = L/(kA) |
A long, thin rod of poor conductor has a large R. A short, thick rod of good conductor has a small R.
Rods in series
When rods are joined end to end, the same heat current passes through each one in steady state. The resistances add:
R_total = R₁ + R₂
P = (Thot − Tcold) / (R₁ + R₂)
The temperature drop across each rod is P × R, so the larger resistance takes the larger drop. The junction temperature is T_hot − P R₁.
The code below checks a worked example. A 0.5 m rod with k = 400 W/(m K) is joined to a 0.5 m rod with k = 200 W/(m K). Both have area 1.0×10⁻⁴ m², and the ends are held at 100 °C and 0 °C.
A = 1.0e-4 # m^2, same cross-section for both rods
L1, k1 = 0.5, 400.0 # m, W/(m K)
L2, k2 = 0.5, 200.0
T_hot, T_cold = 100.0, 0.0
R1 = L1 / (k1 * A) # thermal resistance, K/W
R2 = L2 / (k2 * A)
P = (T_hot - T_cold) / (R1 + R2) # steady heat current in watts
T_junction = T_hot - P * R1
print(round(P, 2), round(T_junction, 1)) # 2.67 66.7The heat current is about 2.67 W. The junction sits at about 66.7 °C. It is closer to the cold end because the poorer conductor takes most of the temperature drop.
Rods in parallel
When rods connect the same two temperatures side by side, each has the same ΔT, and the heat currents add. Conductances (1/R) add:
1/R_total = 1/R₁ + 1/R₂
P_total = P₁ + P₂
If the rods have equal length and the same ΔT, the equivalent conductivity is a weighted sum of the individual k values. For equal areas, k_eq = (k₁ + k₂)/2.
For series rods with equal area, the equivalent conductivity is keq = 2k₁k₂/(k₁ + k₂), and this is valid only when the two lengths are equal. For unequal lengths use Rtotal = ΣL/(kA) directly.
Common errors
- Adding resistances for parallel rods. Add conductances instead.
- Assuming the temperature drop is equal across series rods. Equal drops would need equal R.
- Mixing units, such as cm with W/(m K). Convert all lengths to metres.
- Applying the steady-state result before the rods have stopped warming up. The same-P rule holds only in steady state.
Exercise
Two rods of equal length and area have k₁ = 400 W/(m K) and k₂ = 200 W/(m K). They are connected in parallel between 100 °C and 0 °C. Taking R₁ = 1 unit, what is the ratio P₁ : P₂, and what is the ratio of the total heat current to the heat current through rod 2 alone?
Show answer
Since R = L/(kA), R₂ = 2R₁. With the same ΔT, P is proportional to 1/R, so P₁ : P₂ = 2 : 1. The total is P₁ + P₂ = 3 parts, so P_total : P₂ = 3 : 1.