Sub topic 12
Steady-state conduction and Fourier's law
This chapter assumes you know the difference between heat and temperature, the Kelvin and Celsius scales, and the idea of a rate of change. It also assumes you can read a simple derivative such as dT/dx as "temperature change per unit length".
What conduction means
Conduction is the transfer of heat through a material by the interaction of neighbouring particles, with no bulk movement of the material. A metal spoon in hot tea warms up along its length by conduction.
Heat always flows from the higher temperature to the lower temperature. The rate of flow is called the heat current, written H or dQ/dt. Its unit is the watt (W), which is one joule per second.
Steady state
A rod is in steady state when the temperature at every point stays constant in time. This does not mean the temperature is the same everywhere. It means each point has stopped changing.
In steady state the rod stores no extra energy. So the heat current is the same through every cross-section. Heat entering one end at a given rate must leave the other end at that same rate. This fact is the basis of almost every conduction problem.
Fourier's law
For a uniform rod of cross-section area A and length L, with its ends held at Thot and Tcold, the heat current is:
H = k A (Thot − Tcold) / L
In differential form, for a small slice of thickness dx:
H = −k A (dT/dx)
The minus sign shows that heat flows toward falling temperature. Here k is the thermal conductivity, a property of the material. Its unit is W/(m·K). Copper has k of about 400 W/(m·K). Steel has about 50 W/(m·K).
The rate of heat flow therefore:
- grows with the area A and the temperature difference,
- falls as the length L increases,
- is larger for materials with larger k.
Temperature profile in a uniform rod
Because H, k and A are constant along the rod, dT/dx is also constant. The temperature falls linearly from the hot end to the cold end. At distance x from the hot end:
T(x) = Thot − (Thot − T_cold) x / L
Insulated sides are assumed here. If the sides lose heat, the heat current is not constant and the profile is no longer a straight line.
Worked example
A copper rod has length 0.5 m and cross-section area 4 × 10⁻⁴ m². Its ends are held at 100 °C and 0 °C. Find the heat current and the temperature 0.1 m from the hot end.
k = 400.0 # W/(m K), copper, approximate
A = 4e-4 # m^2
L = 0.5 # m
T_hot, T_cold = 100.0, 0.0
H = k * A * (T_hot - T_cold) / L
print(H) # 32.0 W
x = 0.1
T_x = T_hot - (T_hot - T_cold) * x / L
print(T_x) # 80.0 deg CThe heat current is 32 W. The gradient is 200 K/m, so the point 0.1 m from the hot end is 20 K cooler, at 80 °C.
Common errors
- Using Celsius or Kelvin in the formula is fine for a temperature difference, because a difference of 1 °C equals a difference of 1 K. Do not use a Celsius value alone where k or another quantity has a kelvin unit in a product with T itself.
- Putting the length in centimetres while k is in W/(m·K). Convert to metres first.
- Using the rod's total surface area instead of the cross-section area A. Heat flows along the rod, so A is the area perpendicular to the flow.
- Forgetting that the heat current is constant in steady state, and treating each part of the rod as having its own rate.
Exercise
Exercise
An iron rod of length 0.2 m and cross-section area 1 × 10⁻³ m² has ends at 90 °C and 10 °C. Take k = 80 W/(m·K). Find the heat current and the temperature at the midpoint.
Show answer
H = kAΔT/L = 80 × 1 × 10⁻³ × 80 / 0.2 = 32 W. The temperature falls linearly, so the midpoint is at (90 + 10)/2 = 50 °C.