Sub topic 18
Choosing Storage for a Scenario and Troubleshooting Symptoms
This chapter assumes you know the basics of HDDs, SSDs, SATA, M.2/NVMe, and RAID levels 0, 1, 5, 6, and 10. It shows how to turn that knowledge into an answer for an exam scenario.
Match the requirement to the device
Find the key requirement in the scenario first. Then pick the cheapest option that meets it.
| Requirement | Best fit |
|---|---|
| Lowest cost per terabyte, bulk storage | 3.5-inch HDD |
| Fast boot, quiet, low power, no moving parts | SATA or NVMe SSD |
| Fastest throughput in a thin laptop | M.2 NVMe SSD |
| Upgrading an older laptop with a 2.5-inch bay | 2.5-inch SATA SSD |
| Speed only, data is disposable | RAID 0 |
| Two drives, simple redundancy | RAID 1 |
| Best balance of capacity and redundancy, 3+ drives | RAID 5 |
| Survive two drive failures | RAID 6 |
| Speed and redundancy, 4+ drives | RAID 10 |
Troubleshooting common symptoms
Start by identifying the drive type. These commands show whether a disk is rotational.
lsblk -d -o NAME,ROTA,SIZE,TYPEA ROTA value of 1 means an HDD. A value of 0 means an SSD.
| Symptom | Likely cause | First step |
|---|---|---|
| Clicking or grinding from the PC | Failing HDD heads or platters | Back up now, then replace the drive |
| Slow performance, HDD, long file operations | Fragmentation or a failing drive | Defragment (HDD only) and check SMART |
| Drive not detected in BIOS/UEFI | Loose cable, wrong M.2 type, dead drive | Reseat cables and check the slot supports SATA or NVMe |
| "No boot device found" | Wrong boot order or damaged boot data | Check boot order, then repair the boot loader |
| RAID reports "degraded" | One member drive failed | Replace the drive and let the array rebuild |
| Array slow during rebuild | Normal parity recalculation | Wait, and avoid heavy use |
| SSD slows over time, nearly full | Little free space for writes | Free space and confirm TRIM is enabled |
Never defragment an SSD. It adds wear and gives no speed benefit.
Common scenario mistakes
- Choosing RAID as a backup. A deleted file, ransomware, or a fire affects every drive in the array. Backups are still required.
- Forgetting the M.2 slot type. An M.2 slot may support SATA, NVMe, or both. Check the motherboard manual.
- Ignoring the hot spare. A hot spare starts rebuilding automatically. A cold replacement needs a technician.
- Counting RAID 0 as redundant. One failure destroys all data.
Exercise
A small office server has four 2 TB drives. The owner wants good read and write speed and the ability to survive one drive failure. Which RAID level fits, and what is the usable capacity?
Show answer
RAID 10 fits because it gives striping speed with mirrored redundancy. Usable capacity is (4 / 2) x 2 TB = 4 TB. RAID 5 would give 6 TB, but it has slower writes because of parity calculations, so speed points to RAID 10.