Sub topic 18
Choosing storage for a scenario and troubleshooting symptoms
This chapter pulls the earlier material together. It assumes you know the difference between storage and RAM, can tell HDDs from SSDs, and have met the RAID levels (0, 1, 5, 6, 10), SATA, and M.2/NVMe. You will use that knowledge to pick storage for a stated need and to diagnose what a failing drive or array looks like.
Choosing storage from requirements
Exam scenarios usually hide the answer in a few keywords. Find the priority (speed, capacity, cost, uptime, or size), then match it to a device.
| Scenario clue | Likely choice | Why |
|---|---|---|
| Boot drive, fast app launch | SATA or NVMe SSD | No moving parts, low latency |
| Thin laptop or small-form-factor PC | M.2 SSD | Small, no cables, no bay needed |
| Cheap bulk storage for archives | 3.5-inch HDD | Lowest cost per TB |
| Video editing scratch space | NVMe SSD | Highest sequential throughput |
| Speed matters, data is disposable | RAID 0 | Striping, no redundancy |
| Two drives, simple redundancy | RAID 1 | Full mirror |
| File server, best capacity with fault tolerance | RAID 5 | One drive of parity overhead |
| Must survive two failed drives | RAID 6 | Double parity |
| Database or busy server, speed plus redundancy | RAID 10 | Striped mirrors, fast rebuilds |
| Old laptop upgrade, 2.5-inch bay | 2.5-inch SATA SSD | Drop-in replacement for the HDD |
Two points cause most wrong answers:
- An M.2 slot does not guarantee NVMe. An M.2 drive can use SATA or PCIe, so check the motherboard or laptop documentation for which the slot supports. A "B+M" keyed SATA M.2 drive may not work in an NVMe-only slot.
- mSATA and M.2 are different connectors. They are not interchangeable even though both are small.
You can also confirm what is installed before you buy or swap anything. On Windows:
Get-PhysicalDisk | Select-Object FriendlyName, MediaType, BusType, SizeOn Linux, a ROTA value of 1 means a spinning disk:
lsblk -d -o NAME,ROTA,SIZE,TYPEA decision path
Troubleshooting symptoms
Work from the symptom to the likely cause, then test the cheapest explanation first. Cables and settings fail more often than drives do.
HDD symptoms
- Clicking, grinding, or repeated spin-up noises point to failing heads or bearings. Back up immediately and replace the drive. Do not keep running it to see what happens.
- Slow performance, freezes, and file corruption can mean bad sectors. Check the SMART status (the drive's built-in health reporting) and run a disk check.
- "No boot device" or "Operating system not found" can mean a dead drive, a loose cable, a wrong boot order, or a damaged boot record. Check the firmware setup screen first. If the drive is not listed, reseat the data and power cables.
- Drive disappears intermittently often means a bad SATA cable or power connector. Swap the cable before blaming the drive.
SSD symptoms
- A drive that suddenly vanishes is typical of SSD failure. Unlike an HDD, an SSD often gives little warning.
- Drive turns read-only is a common end-of-life behavior. NAND flash cells wear out after a limited number of writes, and the controller may lock the drive to protect data.
- Slowdowns on a nearly full drive are normal, because the controller has fewer free blocks to work with. Free space or move data off.
- M.2 drive not detected has several causes. The drive may not be fully seated, the slot may support only SATA or only NVMe, or the slot may share lanes with a SATA port. Using one disables the other.
RAID symptoms
- Array shows "degraded" means one drive has failed or dropped out, but data is still available through mirroring or parity. Replace the failed drive promptly. Performance is reduced until the rebuild finishes.
- Array shows "failed" or "offline" means too many drives were lost for the level (two in RAID 5, for example, or both halves of one RAID 10 mirror pair). Recovery usually means restoring from backup.
- Array not found after a controller or motherboard change is often a metadata or driver problem. The RAID configuration is stored on the drives and the controller, so do not reinitialize the disks. Reinitializing destroys the data.
- Slow rebuild is normal. A rebuild reads every surviving drive in full, and the array stays under load meanwhile. This is why a second failure during a RAID 5 rebuild is a real risk.
- Wrong drive pulled is a human error. Always match the failed drive's bay or serial number to the controller's report before removing anything. Pulling a healthy drive from a degraded RAID 5 takes the array offline.
On Windows you can read basic health from the same cmdlet used earlier:
Get-PhysicalDisk | Select-Object FriendlyName, MediaType, BusType, HealthStatus, OperationalStatusHealthStatus reports Healthy, Warning, or Unhealthy. A Warning on a drive in a mirror or parity set should trigger a backup check and a replacement plan.
A general order of operations
- Identify the symptom and when it started. Ask what changed recently.
- Back up any data you can still read before you test further.
- Check the simple things: cables, power connectors, seating, and firmware settings.
- Check the software view: SMART data, disk management, RAID controller utility, and event logs.
- Replace the suspect part and verify the result, such as a completed rebuild or a clean boot.
- Document what you found and what you changed.
Putting it together: two worked cases
Case 1. A small office wants a file server with four 4 TB drives. It needs to survive one drive failure and wants as much usable space as possible. RAID 5 gives (4 − 1) × 4 = 12 TB. RAID 10 gives only 8 TB, so RAID 5 fits the stated priority. If the question adds "must survive two failures," the answer changes to RAID 6 with (4 − 2) × 4 = 8 TB.
Case 2. A user's desktop boots slowly, then shows clicking noises, and files are intermittently unreadable. The HDD is failing mechanically. The order is to back up what is readable, replace the drive, and restore. An SSD is the sensible replacement. Running a disk check or defragmenting would add wear to a failing drive and will not fix the cause.
Exercise
A technician sees "degraded" on a four-drive RAID 5 array in a server. A drive's amber light is on. What should the technician do first, and why should they avoid pulling any other drive?
Show answer
Confirm which drive failed by matching the bay or serial number to the controller report, make sure a current backup exists, then hot-swap only the failed drive and let the array rebuild. A RAID 5 array tolerates one failed drive. Pulling a second drive, even a healthy one, takes the array offline and risks data loss.
Exercise
A new laptop has an M.2 slot, and a user installs an M.2 drive that the system does not detect. List two likely causes.
Show answer
The slot may support only one interface (SATA or NVMe) and the drive uses the other, or the drive is not fully seated or is the wrong key type. Sharing lanes with a SATA port, or a disabled slot in firmware settings, are other valid causes.
Exercise
A workstation needs fast storage for temporary video render files. The files can be regenerated and no redundancy is required. Which option fits best?
Show answer
An NVMe SSD, or RAID 0 across fast SSDs if even more throughput is needed. RAID 0 has no fault tolerance, which is acceptable because the data is disposable.