Sub topic 11
Overshoot, peak time, and settling in the underdamped case
This chapter assumes you can already write the underdamped step response of a series RLC circuit and know the terms α, ω₀, and ω_d. Here you will turn that formula into three numbers that describe how the response looks: how far it overshoots, when it peaks, and how long it takes to settle.
The response we are measuring
For a step Vs applied with zero initial energy, the capacitor voltage is
v(t) = Vs [1 − e^(−αt) (cos ωd t + (α/ωd) sin ω_d t)]
Here α = R/(2L), ω₀ = 1/√(LC), ζ = α/ω₀, and ω_d = ω₀√(1 − ζ²). The final value is Vs. The response rings around that value and the ringing shrinks with the envelope e^(−αt).
Peak time
The peaks and valleys occur where dv/dt = 0. Differentiating gives
dv/dt = Vs (ω₀²/ωd) e^(−αt) sin(ωd t)
This is zero when ω_d t = nπ. The first peak is at n = 1:
tp = π/ωd
Later extrema fall at 2π/ωd, 3π/ωd, and so on. They alternate above and below Vs.
Overshoot
Put t_p into v(t). Since cos π = −1 and sin π = 0:
v(tp) = Vs (1 + e^(−απ/ωd))
Because α/ω_d = ζ/√(1 − ζ²), the percentage overshoot depends only on ζ:
%OS = 100 · exp(−πζ/√(1 − ζ²))
| ζ | Overshoot |
|---|---|
| 0.1 | 72.9% |
| 0.3 | 37.2% |
| 0.5 | 16.3% |
| 0.7 | 4.6% |
Doubling L or C changes ζ, but scaling R, L, and C together so that ζ stays fixed leaves the overshoot unchanged. Overshoot is a statement about shape, not speed.
Settling time
The oscillation is bounded by the envelope Vs (ω₀/ωd) e^(−αt). The response stays within 2% of the final value once this envelope drops below 0.02 Vs. Ignoring the factor ω₀/ωd, which is close to 1 for small ζ, gives the common estimate
t_s ≈ 4/α = 8L/R
Setting e^(−αt) = 0.02 gives the same result, since e^(−4) ≈ 0.018. For ζ below about 0.7 the estimate holds within a few percent.
Worked example
Take R = 20 Ω, L = 1 mH, C = 1 µF, and Vs = 10 V.
- α = 10 000 rad/s and ω₀ ≈ 31 623 rad/s, so ζ ≈ 0.316.
- ω_d = 31 623 · √(1 − 0.1) ≈ 30 000 rad/s.
- %OS = 100 · exp(−π · 0.3333) ≈ 35.1%, because ζ/√(1 − ζ²) = 1/3.
- t_p = π/30 000 ≈ 104.7 µs.
- The peak voltage is 10 · 1.351 ≈ 13.5 V.
- t_s ≈ 4/10 000 = 400 µs.
The same calculation in code:
import math
def underdamped_metrics(R, L, C):
alpha = R / (2 * L)
w0 = 1 / math.sqrt(L * C)
zeta = alpha / w0
if zeta >= 1:
raise ValueError("circuit is not underdamped")
wd = w0 * math.sqrt(1 - zeta**2)
overshoot_pct = 100 * math.exp(-math.pi * zeta / math.sqrt(1 - zeta**2))
peak_time = math.pi / wd
settling_time = 4 / alpha
return zeta, overshoot_pct, peak_time, settling_time
zeta, os_pct, tp, ts = underdamped_metrics(20, 1e-3, 1e-6)
print(f"zeta={zeta:.3f}, overshoot={os_pct:.1f}%, "
f"peak={tp*1e6:.1f} us, settling={ts*1e6:.0f} us")It prints zeta=0.316, overshoot=35.1%, peak=104.7 us, settling=400 us, matching the hand result.
Common errors
- Using ω₀ instead of ω_d in the peak time. The ringing is slower than the undamped frequency.
- Computing settling time from ω_d. Settling depends on the decay rate α, not on the oscillation rate.
- Applying these formulas to ζ ≥ 1. There is no peak and no overshoot in the overdamped and critically damped cases.
Exercise
A series RLC circuit has R = 40 Ω, L = 1 mH, and C = 1 µF, driven by a step from rest. Find ζ, the percentage overshoot, the peak time, and the 2% settling time estimate.
Show answer
α = R/(2L) = 20 000 rad/s and ω₀ ≈ 31 623 rad/s, so ζ ≈ 0.632 and the circuit is underdamped. ωd = √(ω₀² − α²) = √(6×10⁸) ≈ 24 495 rad/s. ζ/√(1 − ζ²) ≈ 0.8165, so %OS = 100 · exp(−π · 0.8165) ≈ 7.7%. The peak time is π/ωd ≈ 128 µs. The settling time is about 4/α = 200 µs.