Sub topic 15
Storing and Recalling Values
Prerequisites and purpose
Assume you know basic percentages and have used the BA II Plus time value of money (TVM) keys. A memory register is a numbered location that holds one numeric value outside the TVM and worksheet calculations. The BA II Plus provides registers numbered 0 through 9.
Memory registers help when a problem reuses an assumption, such as a tax rate, growth rate, or initial investment. They do not replace the calculator’s worksheets. Store inputs in memory only when doing so makes the calculation easier to check.
The STO and RCL keys
STOstores the displayed value in a selected register.RCLrecalls the value from a selected register and displays it.- The number after
STOorRCLidentifies the register. - Storing a new value in a register overwrites its previous value.
For example, this sequence stores 6% in register 1:
6 STO 1The calculator stores the value 6, not 0.06. Whether you enter a percentage as 6 or 0.06 depends on how you plan to use it. For direct multiplication, store 0.06 when you need the decimal form.
0.06 STO 1
25000 STO 2
RCL 2 × RCL 1 =The result is 1500, representing 6% of 25,000.
| Operation | Key sequence | Result |
|---|---|---|
| Store a value | `value STO register` | Saves the value |
| Recall a value | `RCL register` | Displays the saved value |
| Use a value in a calculation | `RCL register` followed by operators | Inserts the saved value |
A reliable workflow
Use a consistent register map during practice. For example:
- Register 1: discount rate
- Register 2: initial investment
- Register 3: tax rate
Record the map on paper or in your notes. Then clear or overwrite the registers before starting a different problem. A recalled value can look reasonable even when it belongs to an earlier problem.
The following example calculates an after-tax cash flow. It stores a cash flow of 10,000 and a tax rate of 25%, then calculates the cash flow after tax.
10000 STO 1
0.25 STO 2
RCL 1 × ( 1 - RCL 2 ) =The result is 7500.
If your calculator is set to chain calculation mode, use intermediate results or parentheses carefully. In exam conditions, do not rely on an unclear expression order. Recall each stored value and check the displayed value before continuing.
Common errors
- Using the wrong register: Recall the register immediately after storing it to confirm the value.
- Storing a percentage in the wrong form:
25means twenty-five when multiplied directly.0.25means 25% in decimal form. - Assuming registers are automatically cleared: Overwrite the registers you need instead of trusting old contents to be gone.
- Confusing memory with TVM values: A value in register 1 is separate from the value currently stored in
PV,PMT, orFV.
Exercise
Store 12.5% in register 4 and recall it for use as a decimal multiplier. What sequence should you enter?
Show answer
Enter 0.125 STO 4, then enter RCL 4 when the decimal multiplier is needed. Recall the register to confirm that the stored value is 0.125.