Sub topic 4
Signal Detection Theory: Sensitivity Versus Response Bias
Assume you know basic neuron vocabulary, introductory psychology terms, and ratios. Signal detection theory (SDT) is a framework for explaining decisions made under uncertainty. It separates two questions:
- How well can a person distinguish a signal from background noise?
- How willing is the person to report that a signal is present?
This distinction matters because the same accuracy score can result from different decision strategies.
Four possible outcomes
Imagine a radiologist deciding whether an image contains a tumor. The tumor is the signal. Normal visual variation and image noise are the background.
| Reality | Response: signal present | Response: signal absent |
|---|---|---|
| Signal present | Hit | Miss |
| Signal absent | False alarm | Correct rejection |
A hit correctly detects the signal. A miss fails to detect it. A false alarm reports a signal that is not there. A correct rejection correctly reports its absence.
A cautious observer uses a high decision criterion. This observer reports a signal only when the evidence is strong. Caution reduces false alarms but can increase misses. A liberal observer uses a low criterion. This observer detects more real signals but also makes more false alarms.
Sensitivity and bias
Sensitivity is the ability to separate signal trials from noise trials. In SDT, sensitivity is often represented by d-prime, written d′. It combines the hit rate and false-alarm rate:
d′ = z(hit rate) − z(false-alarm rate)
Here, z means the standard normal score for a probability. A larger d′ means better discrimination.
Response bias is the observer's decision rule. A common measure is criterion, written c:
c = −0.5 × [z(hit rate) + z(false-alarm rate)]
A criterion near zero indicates a relatively neutral rule in this coding system. A positive criterion indicates a more cautious response style. A negative criterion indicates a more liberal style.
from statistics import NormalDist
z = NormalDist().inv_cdf
def d_prime(hit_rate, false_alarm_rate):
"""Estimate sensitivity from hit and false-alarm rates."""
return z(hit_rate) - z(false_alarm_rate)
def criterion(hit_rate, false_alarm_rate):
"""Estimate response bias using the criterion measure."""
return -0.5 * (z(hit_rate) + z(false_alarm_rate))
print(round(d_prime(0.84, 0.16), 2)) # 1.99
print(round(criterion(0.84, 0.16), 2)) # 0.0The example has a hit rate of 0.84 and a false-alarm rate of 0.16. Its d′ is about 1.99, showing useful separation between signal and noise. Its criterion is about zero, suggesting neither a strongly cautious nor strongly liberal rule.
Reading changes in performance
If training raises the hit rate while leaving the false-alarm rate unchanged, sensitivity probably improved. If both the hit rate and false-alarm rate rise, the observer may have lowered the criterion instead. To evaluate a change, examine both rates rather than accuracy alone.
Exercise
An observer has a hit rate of 0.90 and a false-alarm rate of 0.40. What does the high false-alarm rate suggest, even if the hit rate is high?
Show answer
The observer may be using a liberal response criterion. Calculate sensitivity with d′ before concluding that discrimination is excellent.