Sub topic 10
Voltage regulation with a Zener diode
This chapter assumes you know Ohm's law, series and parallel circuits, Kirchhoff's current law, and the reverse breakdown behavior of a Zener diode from the previous chapter.
What a regulator must do
A supply voltage can drift, and a load can draw different currents. A voltage regulator keeps the load voltage nearly constant despite both. A Zener diode does this because, in reverse breakdown, its voltage stays close to the Zener voltage $V_Z$ while its current changes over a wide range.
The circuit
The Zener diode is connected in reverse bias, in parallel with the load. A series resistor $R_s$ sits between the supply and this parallel pair.
How it works
The load voltage equals the Zener voltage, so $V{out} = VZ$. The series resistor drops the rest of the input voltage.
- Current through the series resistor: $I = \dfrac{V{in} - VZ}{R_s}$
- Current through the load: $IL = \dfrac{VZ}{R_L}$
- By Kirchhoff's current law, $I = IL + IZ$, so $IZ = I - IL$
If the input voltage rises, $I$ rises. The extra current goes through the Zener diode, not the load, and the load voltage stays at $VZ$. If the load current rises, $IZ$ falls by the same amount, so $I$ stays the same. The regulator works only while $IZ$ stays above a small minimum value. If $IZ$ falls to zero, the diode leaves breakdown and regulation stops.
Worked example
Take $V{in} = 12$ V, $VZ = 5.6$ V, $Rs = 100\ \Omega$ and $RL = 560\ \Omega$. The script applies the three steps above.
v_in = 12.0 # supply voltage in volts
v_z = 5.6 # Zener breakdown voltage in volts
r_series = 100.0 # series resistor in ohms
r_load = 560.0 # load resistor in ohms
i_total = (v_in - v_z) / r_series # current through the series resistor
i_load = v_z / r_load # current through the load
i_zener = i_total - i_load # remaining current flows through the Zener
print(f"Total current: {i_total * 1000:.1f} mA")
print(f"Load current: {i_load * 1000:.1f} mA")
print(f"Zener current: {i_zener * 1000:.1f} mA")The output is 64.0 mA total, 10.0 mA through the load and 54.0 mA through the Zener diode.
Common errors
- Using $V{in}$ instead of $V{in} - VZ$ when finding the current in $Rs$. The resistor sees only the voltage that is left after the Zener.
- Treating the Zener current as equal to the series current. Subtract the load current first.
- Forgetting that the Zener diode must be reverse biased. Forward biased, it acts as an ordinary diode with a drop of about 0.7 V.
- Connecting the load in series with the Zener diode. The load must be in parallel.
Exercises
Exercise
A Zener diode with $VZ = 6$ V is used with $V{in} = 10$ V and $Rs = 200\ \Omega$. The load is $RL = 1\ \text{k}\Omega$. Find the current through the Zener diode.
Show answer
The series current is $(10 - 6)/200 = 20$ mA. The load current is $6/1000 = 6$ mA. The Zener current is $20 - 6 = 14$ mA.
Exercise
In the same circuit, the load is disconnected. What are the load voltage and the Zener current?
Show answer
The load voltage stays at 6 V because the Zener diode is still in breakdown. The load current is zero, so the Zener current equals the series current, 20 mA.