Sub topic 9
Power Problems and Protective Devices
This chapter assumes you know basic PC hardware, such as the power supply unit (PSU) and wall outlets. It also assumes you have some help desk experience. The earlier chapter on electrical safety covered the danger of working near live circuits. This chapter covers what happens when the power itself is wrong, and which device you choose to protect equipment from each fault. The A+ exam asks you to match a symptom to a power problem and then to the right device.
The Working Model
Wall power is supposed to arrive at a steady voltage (about 120 V in North America, 230 V in much of the world). Every deviation from that steady level falls into one of a few categories. Each category has a different cause and a different fix.
The exam groups these by what the voltage does:
| Problem | What the voltage does | Typical duration | Common cause |
|---|---|---|---|
| Blackout | Drops to zero | Minutes to days | Grid failure, tripped breaker, storm damage |
| Brownout | Stays low but not zero | Seconds to hours | Heavy demand on the grid, overloaded circuit |
| Sag (dip) | Drops briefly | Fractions of a second to seconds | A large motor or compressor starting up |
| Surge | Rises above normal | Seconds | Power returning after an outage, grid switching |
| Spike | Rises sharply | Microseconds to milliseconds | Lightning, utility switching, faulty wiring |
| Noise | Signal is distorted | Continuous or intermittent | Electromagnetic interference (EMI) or radio frequency interference (RFI) from motors, fluorescent lights, or radios |
Two terms are easy to mix up. A sag is a short drop. A brownout is a longer one. A surge is a longer rise. A spike is a very short, very sharp rise. The exam usually separates them by duration, so read the wording of the question for clues such as "momentary" or "extended."
Why Each Problem Hurts
- Blackouts cause unsaved work to be lost and can corrupt files if a drive was writing at that moment. A hard shutdown can also damage the operating system.
- Brownouts and sags make the PSU work harder to deliver the same power. Symptoms include random reboots, freezes, and drives that spin down. Repeated low voltage can shorten component life.
- Surges and spikes push too much energy into components. A spike can destroy a PSU or motherboard in one event. Smaller surges cause gradual damage that shows up later as unexplained failures.
- Noise is usually mild. It can cause data errors on sensitive equipment and audible hum or interference on audio gear.
Protective Devices
Each device handles a different part of the problem. No single device handles everything.
Surge Protector
A surge protector (also called a surge suppressor) is a power strip with components that divert excess voltage to ground. It protects against surges and spikes. It does nothing during a blackout or a brownout, because it stores no power and does not raise low voltage.
Look at the rating when you choose one:
- Joules measure how much energy it can absorb before it fails. Higher is better.
- Clamping voltage is the voltage at which it starts diverting energy. Lower is better.
- Response time is how quickly it reacts, usually in nanoseconds.
A surge protector wears out. Each large surge uses up some of its capacity. Many units have an indicator light that shows whether the protection is still active. When the light goes out, the unit may still pass power but no longer protect anything. Replace it.
A plain power strip with no protection circuit is not a surge protector. It only adds outlets.
Uninterruptible Power Supply (UPS)
A UPS contains a battery. It keeps equipment running briefly when the power fails, which gives users time to save work and shut down cleanly. Most also include surge protection.
There are three common designs:
| Type | How it works | Trade-off |
|---|---|---|
| Standby (offline) | Passes wall power through and switches to battery when power fails | Cheapest. A short switchover delay, and little help with sags |
| Line-interactive | Adjusts low or high voltage with a transformer, and uses the battery only when needed | Good for brownouts and sags. Common for desktops and small offices |
| Online (double conversion) | Always runs equipment from the battery inverter, with the wall charging it | Cleanest power and no switchover gap. Most expensive and generates more heat |
Size a UPS by the load it must carry. Add up the wattage of the devices, or use the volt-amp (VA) rating on the device labels, and choose a UPS with headroom. Runtime is typically a few minutes, which is enough for a graceful shutdown and not enough to keep working through a long outage.
A UPS battery is a consumable. It usually lasts three to five years. Test the UPS regularly, and replace the battery when the unit warns you or fails a self-test. Spent batteries go to recycling, as covered in the disposal chapter.
> Do not plug a laser printer into a UPS sized for computers. A laser printer's fuser draws a large current and can overload the unit.
Power Conditioner and Voltage Regulator
A power conditioner smooths noise and keeps the voltage steady. An automatic voltage regulator (AVR) corrects sags and surges without switching to the battery. These help in places where voltage often drifts, such as older buildings.
Matching Problems to Devices
| Symptom or scenario | Best answer |
|---|---|
| Lightning storm risk, equipment is otherwise stable | Surge protector |
| Server must shut down cleanly when power fails | UPS |
| Lights dim when the air conditioner starts, and the PC reboots | Line-interactive UPS or voltage regulator |
| Audio hum or interference from nearby motors | Power conditioner, or move the equipment |
| Critical system needs no switchover gap | Online UPS |
Diagram: Choosing a Device
Common Errors
- Treating a surge protector as backup power. It has no battery.
- Daisy-chaining. Plugging one power strip or surge protector into another can overload the first outlet and create a fire risk. Plug each into the wall.
- Using an extension cord as permanent wiring. Use a rated power strip, and keep cords out of walkways to avoid trip hazards.
- Ignoring end of life. A surge protector with a dead indicator and an old UPS battery both give a false sense of safety.
- Overloading the UPS. Check total load against the rating, and leave margin.
- Plugging a surge protector into a UPS output and a UPS into a surge protector without checking the manufacturer's advice. Follow the vendor's guidance, since some designs do not tolerate it well.
Troubleshooting Approach
When a customer reports random reboots or dead equipment, check power before replacing parts.
- Ask whether it happens at certain times, such as when large appliances start.
- Check how the device is plugged in: wall, power strip, surge protector, or UPS.
- Look at the protector's indicator light and the UPS display or logs.
- Move the device to a different outlet or circuit and see whether the problem follows.
- Record what you found in the ticket, including the device model and its age.
Exercise
A user's desktop reboots every time the office's large printer-copier starts a job. The desktop is plugged into a basic surge protector. Which problem is this, and what would you recommend?
Show answer
The voltage sags briefly when the copier draws a large current. A surge protector does not fix low voltage. Recommend a line-interactive UPS (or a voltage regulator) for the desktop, and ideally move the copier to a separate circuit.
Exercise
Name the protective device and the reason for each case: (a) a lightning spike through the outlet, (b) a 10-minute blackout while a server is writing to disk.
Show answer
(a) A surge protector, because it diverts excess voltage to ground. (b) A UPS, because its battery keeps the server running long enough for a clean shutdown.