Calibration with more than two classes
This chapter assumes you know binary calibration (reliability diagrams, Brier score, log loss, ECE), Platt scaling, isotonic regression, and softmax. It extends them to K classes.
What "calibrated" means with K classes
A multiclass model outputs a vector of K probabilities. There are three common definitions of calibration for it, from weakest to strongest:
| Definition | Requirement |
|---|---|
| Top-label (confidence) | Among predictions with top probability 0.7, the predicted class is right about 70% of the time. |
| Classwise | For every class k, the probability assigned to k matches how often k occurs. |
| Full | The whole vector matches the true conditional distribution of labels. |
Top-label calibration is the cheapest to measure and the most common. Classwise calibration matters when you use the probability of a specific class, such as "fraud" among five categories.
Measuring it
The top-label ECE bins the maximum probability and compares it with the accuracy in each bin.
import numpy as np
def top_label_ece(y_true, probs, n_bins=10):
y_true = np.asarray(y_true)
probs = np.asarray(probs)
conf = probs.max(axis=1)
correct = (probs.argmax(axis=1) == y_true).astype(float)
edges = np.linspace(0.0, 1.0, n_bins + 1)
bin_ids = np.digitize(conf, edges[1:-1], right=True)
ece = 0.0
for b in range(n_bins):
mask = bin_ids == b
if mask.any():
ece += mask.mean() * abs(correct[mask].mean() - conf[mask].mean())
return eceFor a proper scoring rule, log loss works unchanged. The multiclass Brier score is the mean over samples of the squared distance between the probability vector and the one-hot label.
Calibrating with CalibratedClassifierCV
For K > 2, scikit-learn calibrates one-vs-rest. It fits one calibrator per class, treating that class as positive. It then renormalizes the K calibrated values so they sum to 1.
import numpy as np
from sklearn.calibration import CalibratedClassifierCV
from sklearn.datasets import make_classification
from sklearn.metrics import log_loss
from sklearn.model_selection import train_test_split
from sklearn.naive_bayes import GaussianNB
def top_label_ece(y_true, probs, n_bins=10):
conf = probs.max(axis=1)
correct = (probs.argmax(axis=1) == y_true).astype(float)
edges = np.linspace(0.0, 1.0, n_bins + 1)
bin_ids = np.digitize(conf, edges[1:-1], right=True)
ece = 0.0
for b in range(n_bins):
mask = bin_ids == b
if mask.any():
ece += mask.mean() * abs(correct[mask].mean() - conf[mask].mean())
return ece
X, y = make_classification(
n_samples=20000, n_features=20, n_informative=5, n_redundant=10,
n_classes=3, random_state=0,
)
X_train, X_test, y_train, y_test = train_test_split(X, y, test_size=0.5, random_state=0)
models = {"raw": GaussianNB().fit(X_train, y_train)}
for method in ("sigmoid", "isotonic"):
models[method] = CalibratedClassifierCV(GaussianNB(), method=method, cv=5).fit(X_train, y_train)
for name, model in models.items():
p = model.predict_proba(X_test)
print(f"{name:<9} ECE={top_label_ece(y_test, p):.3f} log loss={log_loss(y_test, p):.3f}")Temperature scaling and the argmax
Temperature scaling divides all K logits by one scalar T before the softmax. It has one parameter, so it rarely overfits, and it never changes which class has the highest score. Accuracy stays identical. It fixes top-label calibration well but cannot repair class-specific distortions.
One-vs-rest calibrators can change the argmax. Accuracy may shift slightly after calibration, so check it.
Common errors
- Reading a one-vs-rest reliability diagram for class 2 as if it covered the whole model.
- Evaluating ECE with many bins on a small test set. Mass concentrates in the top bin, and the other bins are noisy.
- Fitting isotonic regression per class on rare classes. A class with few positives gives a jagged, overfit step function. Prefer sigmoid or temperature scaling there.
Exercise
A three-class model has 90% accuracy and a top-label ECE of 0.01. A colleague wants to use its probability for the rarest class in a cost-sensitive decision. Why is the low ECE not enough, and what should you check?
Show answer
Top-label ECE only tests the maximum probability. The probability of a specific rare class can still be miscalibrated. Check classwise calibration: build a one-vs-rest reliability diagram for that class and compute its binary ECE or Brier score.