Sub topic 2
What a Power Supply Does
This chapter assumes you know the basic PC components (CPU, RAM, motherboard, storage, GPU), have seen the inside of a desktop case, and have a rough idea of volts, amps, and watts. It covers the job of the power supply unit (PSU), how it converts power, what it protects against, and where it fails. Later chapters cover connectors, sizing, and efficiency in detail.
The core job: AC in, DC out
Wall outlets deliver alternating current (AC). The voltage swings back and forth many times per second, which suits long-distance power distribution. PC components need direct current (DC), where voltage stays steady at a fixed level. The PSU bridges the two.
A PSU does four things:
- Converts AC input to several low DC voltages.
- Regulates each output so it stays close to its target as load changes.
- Distributes power through cables and connectors to the motherboard, drives, and add-in cards.
- Signals the motherboard that power is stable before the system starts.
Most PCs use a switching power supply. It rectifies the AC into high-voltage DC, chops it at high frequency, steps it down with a small transformer, and filters it into clean outputs. This design is small, light, and efficient compared with the older heavy linear transformers.
The DC rails
An output voltage line inside the PSU is called a rail. Modern PCs use three main positive rails:
| Rail | Typical use |
|---|---|
| +3.3 V | Some logic circuits, M.2 and SATA drive electronics, RAM-related circuits on older designs |
| +5 V | USB ports, SATA drive logic, some motherboard circuits |
| +12 V | CPU, GPU, fans, drive motors, and most of the system's power |
The +12 V rail carries the bulk of the load in a modern PC. The CPU and GPU draw from +12 V, and the motherboard converts it down locally with voltage regulator modules (VRMs). This is why +12 V capacity is the number that matters most when you judge a PSU.
The older -12 V rail still appears on the 24-pin connector for legacy compatibility. It carries very little current. Be ready to recognize it, but you will rarely see it matter in practice.
Control signals
Besides power, the PSU talks to the motherboard through a few signal lines on the 24-pin connector. The exam expects you to know these:
- PS_ON is a signal the motherboard pulls to ground to tell the PSU to turn on. When you press the case power button, the motherboard asserts this line.
- PWR_OK (power good) is sent by the PSU to the motherboard after the outputs have stabilized. The CPU is held in reset until this signal arrives. A bad PWR_OK signal can cause random restarts or a system that never starts.
- +5 VSB (standby) stays live whenever the PSU is plugged in and its rear switch is on, even when the PC is off. It powers the motherboard's wake circuits, such as the power button logic, Wake-on-LAN, and USB charging when enabled.
The standby rail has a practical consequence. A PC that is "off" is not unpowered. Parts of the motherboard stay energized as long as the cord is connected and the switch is on. Unplug the cord before you open the case or reseat parts.
Why the PSU needs to be a stable source
Components tolerate only small voltage variations. The ATX standard allows about ±5% on the main positive rails. A rail that sags under load can crash the system. A rail that spikes can damage parts. Regulation, filtering, and protection circuits keep outputs inside that window.
Good PSUs include protection features. You will see these abbreviations in specifications and exam questions:
| Protection | What it guards against |
|---|---|
| OVP (over-voltage) | Output voltage rising too high |
| UVP (under-voltage) | Output voltage dropping too low |
| OCP (over-current) | Too much current on a rail |
| OPP (over-power) | Total load above the unit's rating |
| SCP (short-circuit) | A direct short on an output |
| OTP (over-temperature) | Internal heat above a safe limit |
When one of these trips, the PSU shuts down. The usual recovery is to turn off the PSU, remove the cause, wait a short time, and power on again. A PSU that keeps shutting down is telling you something is wrong with the load or the PSU itself.
Heat and cooling
A PSU wastes some energy as heat, because conversion is never perfect. A fan, usually 120 mm or larger on a standard unit, pulls air through the case of the PSU. Some units run the fan only above a load threshold, which is sometimes called a zero-RPM mode.
Two points matter for troubleshooting:
- Dust and blocked vents raise internal temperatures and shorten component life.
- Mounting orientation affects airflow. A PSU with a bottom intake needs a case with a vent below it. Fitting it facing the floor on a carpet suffocates it.
Worked example: reading a PSU label
Suppose a label shows these outputs:
Input: 100-240 V~, 50-60 Hz, 8 A
+3.3 V: 20 A
+5 V: 20 A
+12 V: 45 A
Combined +3.3 V and +5 V: 120 W
Total: 600 WPower in watts is volts multiplied by amps. The +12 V rail can deliver 12 × 45 = 540 W. The +3.3 V and +5 V rails together are capped at 120 W. The total of 600 W is the most the PSU can deliver overall, so you cannot use every rail at its maximum at once. This 600 W figure is a DC output rating. The unit draws more than that from the wall because of conversion losses.
The input line tells you the PSU accepts 100 to 240 V AC at 50 or 60 Hz. That is an auto-switching (universal) input, which the next chapter on input voltage covers.
Common failure signs
Symptoms often point to the PSU before they point to any other part:
- The system does not power on at all, with no fans and no lights.
- The system restarts at random, especially under load such as gaming.
- The PC shuts down without warning when the GPU or CPU gets busy.
- Burning smell, visible smoke, or a loud buzzing or clicking noise from the unit.
- Fan fails to spin on the PSU.
Intermittent faults are the hardest. A weak PSU can pass light tasks and fail under heavy load, so the failure may look like a CPU, RAM, or GPU problem. Swapping in a known-good PSU is the cleanest test.
Safety rules
- Never open a PSU case. Capacitors inside can hold a dangerous charge long after the unit is unplugged. Replace the whole unit instead of repairing it.
- Unplug the power cord before working inside the PC, and press the power button once afterward to drain residual charge.
- Do not force connectors. They are keyed, which means shaped so they fit only one way.
- Keep liquids and loose metal away from an open case.
Quick check on a dead system
A basic PSU check uses a PSU tester or a multimeter. A tester plugs into the 24-pin connector and shows whether each rail is in range. A multimeter on the connector's pins can confirm voltages, but you must be careful not to short adjacent pins. If the rails read within tolerance, look elsewhere. If one reads out of range, replace the PSU.
Exercise
A technician unplugs a PC from the wall but leaves the PSU rear switch on. Which PSU line is still live inside the PSU while the cord is connected, and which signal tells the CPU the outputs have stabilized?
Show answer
The +5 VSB standby line is live whenever the PSU has AC input and the switch is on. The PWR_OK (power good) signal tells the motherboard the outputs are stable so the CPU can leave reset.
Exercise
A PSU label lists +12 V at 40 A. How much power can that rail supply, and why might the PSU still be unable to deliver that amount while the other rails are also loaded?
Show answer
12 V × 40 A = 480 W. The PSU also has a total wattage limit, and the +3.3 V and +5 V rails share part of it. If all rails are loaded, the combined draw can exceed the total rating even though each rail is within its own limit.