Sub topic 8
Electricity at home: Ohm's law, fuses, earthing and units of energy
This chapter assumes you know the SI units from the earlier chapters (volt, ampere, ohm, watt, joule) and the idea of power as work done per unit time. It builds the working model of a household circuit and covers the numerical and conceptual points that MPSC Prelims tends to test.
The working model: voltage, current and resistance
Three quantities describe a simple circuit.
- Potential difference (voltage, V) is the energy given to each unit of charge. It is measured in volts.
- Current (I) is the rate of flow of charge. It is measured in amperes. One ampere is one coulomb per second.
- Resistance (R) is the opposition a material offers to current. It is measured in ohms.
Ohm's law says that, at constant temperature, the current through a conductor is proportional to the potential difference across it:
V = I × R
Power follows from P = V × I. Combining the two relations gives P = I²R and P = V²/R.
| Quantity | Symbol | SI unit | Instrument |
|---|---|---|---|
| Potential difference | V | volt (V) | voltmeter, connected in parallel |
| Current | I | ampere (A) | ammeter, connected in series |
| Resistance | R | ohm (Ω) | ohmmeter |
| Power | P | watt (W) | wattmeter |
| Electrical energy | E | joule (J), or kWh | energy meter |
Resistance of a wire depends on its material, length and cross-section: R = ρL/A. A longer wire has more resistance. A thicker wire has less. This is why heavy appliances use thicker cables.
A worked example
The program below applies Ohm's law to a heater, then converts the result into billing units.
voltage = 230.0 # volts, household supply in India
resistance = 46.0 # ohms, a heater element
current = voltage / resistance # Ohm's law: I = V / R
power = voltage * current # P = V * I
print(current, power) # 5.0 A, 1150.0 W
hours_per_day = 2
days = 30
units_kwh = power / 1000 * hours_per_day * days
print(units_kwh) # 69.0 units (kWh)The heater draws 5 A and uses 1150 W. Run for 2 hours a day over 30 days, it consumes 69 units.
Series and parallel circuits
How loads are connected decides how they behave.
| Feature | Series | Parallel |
|---|---|---|
| Current | Same through every part | Divides among branches |
| Voltage | Divides among parts | Same across every branch |
| Total resistance | R = R₁ + R₂ + … | 1/R = 1/R₁ + 1/R₂ + … |
| If one device fails | The whole circuit stops | Other branches keep working |
Homes are wired in parallel. Every appliance gets the full 230 V, and switching one off does not affect the others. The total resistance in parallel is smaller than the smallest single resistance. Adding more appliances therefore raises the total current drawn from the supply.
The heating effect and fuses
When current flows through a resistance, electrical energy turns into heat. The Joule heating law gives the heat produced:
H = I²Rt
Heat grows with the square of the current. Doubling the current gives four times the heat. This effect is useful in heaters, irons, toasters and bulb filaments. It is dangerous when a circuit carries too much current.
A fuse is a safety device that protects a circuit from overcurrent. It is a thin wire of a material with a low melting point, connected in series with the circuit. If the current exceeds the rated value, the wire heats up, melts and breaks the circuit.
- Fuse wire is commonly an alloy of tin and lead. Its melting point is low and its resistance is high.
- It must be placed in the live wire, so that the appliance is disconnected from the supply when it blows.
- The fuse rating should be slightly above the normal working current. A 5 A fuse suits a load that draws about 3 to 4 A.
Overcurrent has two common causes.
- Overloading: too many appliances on one circuit, which raises the total current.
- Short circuit: live and neutral wires touch directly, resistance drops almost to zero, and the current becomes very large.
Modern homes also use a miniature circuit breaker (MCB). It trips automatically and can be reset, so it does not need replacing. A residual current device (RCD or ELCB) detects leakage current to earth and cuts the supply.
Domestic wiring and earthing
Indian household supply is alternating current at 230 V and 50 Hz. Three wires enter a home.
| Wire | Colour (current Indian practice) | Older colour | Role |
|---|---|---|---|
| Live (phase) | Red | Red | Carries current to the appliance at high potential |
| Neutral | Black | Black | Returns current to the source |
| Earth | Green | Green | Safety path to the ground |
Colour codes have changed over time, and question setters usually ask only for live red, neutral black and earth green. The neutral wire is near zero potential. The live wire is the one that gives a shock.
Earthing connects the metal body of an appliance to the ground through the earth wire. If the live wire touches the metal casing, the fault current flows safely to the ground through this low-resistance path. The large current also blows the fuse or trips the breaker. Without earthing, the casing would stay at 230 V and the next person to touch it would receive the shock.
- Earthing is used for appliances with metal bodies: refrigerators, washing machines, geysers, irons.
- The earth pin on a three-pin plug is longer and thicker. It makes contact first and breaks contact last.
- Earthing is a safety measure. It does not change how the appliance normally works.
Units of electrical energy
Power is the rate of using energy, so energy equals power multiplied by time.
- The joule is the SI unit of energy. It is equal to one watt-second, which is very small.
- The kilowatt-hour (kWh) is the commercial unit. It is the energy used by a 1 kW load running for 1 hour.
- The "unit" on an electricity bill is one kWh.
1 kWh = 1000 W × 3600 s = 3.6 × 10⁶ J
The conversion for cost is straightforward.
def monthly_cost(watts, hours_per_day, days, rate_per_unit):
units = watts / 1000 * hours_per_day * days
return units, units * rate_per_unit
# Example: a 60 W fan running 10 hours a day for 30 days at Rs 7 per unit
units, cost = monthly_cost(60, 10, 30, 7.0)
print(units) # 18.0 units
print(cost) # 126.0 rupeesPower ratings printed on appliances, such as "60 W, 230 V", let you work out the resistance (R = V²/P) and the current (I = P/V).
Common errors and exam traps
- Confusing the watt and the kilowatt-hour. The watt measures power. The kilowatt-hour measures energy.
- Forgetting to divide by 1000. Convert watts to kilowatts before multiplying by hours.
- Assuming Ohm's law holds for everything. It fails for non-ohmic devices such as diodes and for filaments whose resistance rises with temperature.
- Placing the fuse in the neutral wire. The fuse and switch belong on the live wire.
- Mixing up instrument connections. An ammeter goes in series and has very low resistance. A voltmeter goes in parallel and has very high resistance.
- Saying that current is "used up". Charge keeps circulating. It is energy that is transferred to the appliance.
- Believing a higher-wattage bulb has higher resistance. At fixed voltage, R = V²/P, so a higher wattage means lower resistance.
Exercise
A 2000 W geyser runs for 90 minutes a day for 30 days. The tariff is Rs 8 per unit. What is the monthly cost, and what current does the geyser draw at 230 V (to one decimal place)?
Show answer
Energy per day = 2 kW × 1.5 h = 3 kWh. Over 30 days this is 90 units. Cost = 90 × 8 = Rs 720. Current = P/V = 2000/230 ≈ 8.7 A.
Exercise
Why must the fuse be connected in the live wire, and why should a 5 A fuse not be replaced with a piece of copper wire?
Show answer
A fuse in the live wire disconnects the appliance from the high-potential side once it blows, so no part of the appliance stays live. Copper has a high melting point and low resistance, so it will not melt at a dangerous current. The cables could overheat and cause a fire.
Exercise
Two bulbs rated 40 W and 100 W, both for 230 V, are connected in series across a 230 V supply. Which glows brighter, and why?
Show answer
The 40 W bulb. Its resistance (V²/P = 1322.5 Ω) is higher than that of the 100 W bulb (529 Ω). In series, the same current flows through both, and the power dissipated is I²R, so the higher resistance gives more heat and light.