Sub topic 12
How X-rays Are Produced
This chapter assumes you know the electron-volt, potential difference, and the photon relation E = hf = hc/λ. It covers how a Coolidge tube makes X-rays and which quantities you control. The next two chapters cover the continuous and characteristic spectra in detail.
What an X-ray is
X-rays are electromagnetic radiation with wavelengths of roughly 0.01 nm to 10 nm (0.1 Å to 100 Å). A photon of 1 Å has energy 12400 eV·Å / 1 Å = 12.4 keV. That is thousands of times the energy of a visible photon, which is why X-rays penetrate matter.
X-rays are made when fast electrons are suddenly stopped or deflected by a target. The electrons' kinetic energy becomes photon energy, plus a large share of heat.
The Coolidge tube
A Coolidge tube is an evacuated glass tube with two electrodes.
- Filament (cathode): a tungsten coil heated by a low-voltage supply. It emits electrons by thermionic emission.
- Target (anode): a block of a heavy metal such as tungsten or molybdenum. It is set at an angle to the beam.
- High-voltage supply: a potential difference V of tens of kilovolts between cathode and anode accelerates the electrons toward the target.
The tube is evacuated so that the electrons do not lose energy by colliding with gas molecules. The target is often backed by copper or cooled by water or oil, because about 99% of the beam energy ends up as heat.
Energy of the electrons
An electron accelerated from rest through a potential difference V gains kinetic energy
K = eV
With V = 20 kV, each electron arrives with 20 keV. No photon produced can have more energy than this, a fact the next chapter turns into the cut-off wavelength.
Two controls: filament current and tube voltage
The two supplies control different things.
| Control | What it sets | Effect on X-rays |
|---|---|---|
| Filament current | Number of electrons emitted per second (tube current) | Changes intensity (number of photons per second). Does not change photon energy. |
| Accelerating voltage V | Energy of each electron | Changes the penetrating power (hardness) and the shortest wavelength. |
A hotter filament gives more electrons and so a more intense beam. A higher voltage gives a harder beam of shorter wavelength.
Where the energy goes
Most electrons lose their energy in many small collisions with target atoms, which heats the target. Only a small fraction, about 1%, produces X-rays. Two processes produce them:
- Braking radiation (bremsstrahlung): an electron is decelerated by the electric field of a nucleus and radiates a photon. The photon can take any energy up to eV, so this gives a continuous spectrum.
- Characteristic emission: an electron knocks an inner-shell electron out of a target atom. An outer electron drops into the vacancy and emits a photon of a definite energy set by the target element.
Worked example
A tube runs at 20 kV with a tube current of 10 mA. Find the energy of each electron, the number of electrons striking the target per second, and the power delivered to the target.
- Energy per electron: K = eV = 20 keV.
- Electrons per second: N = I/e = (10 × 10⁻³ A) / (1.6 × 10⁻¹⁹ C) ≈ 6.3 × 10¹⁶ s⁻¹.
- Power: P = IV = (10 × 10⁻³)(20000) = 200 W.
e = 1.6e-19 # C
V = 20000 # V
I = 10e-3 # A
energy_eV = V # numerically, K = eV in eV
electrons_per_s = I / e # about 6.25e16
power_W = I * V # 200 W
print(energy_eV, electrons_per_s, power_W)About 99% of the 200 W, roughly 198 W, appears as heat. This is why high-power tubes use rotating anodes or cooling.
Exercise
In a Coolidge tube, the filament current is increased while the accelerating voltage is kept at 30 kV. State what happens to (a) the maximum photon energy and (b) the intensity of the X-rays.
Show answer
(a) The maximum photon energy stays at 30 keV, because each electron still gains eV = 30 keV. (b) The intensity increases, because a hotter filament emits more electrons per second, so more photons are produced per second.
Exercise
Electrons in an X-ray tube are accelerated through 40 kV. A tube current of 5 mA flows. What is the power delivered to the target, and about how much of it appears as X-rays if the efficiency is 1%?
Show answer
P = IV = (5 × 10⁻³ A)(40000 V) = 200 W. At 1% efficiency, about 2 W is emitted as X-rays and about 198 W becomes heat.