Sub topic 14
Complex power and the power triangle
This chapter assumes you can compute impedance and phasor currents (earlier chapters), and that you know instantaneous power is p(t) = v(t)·i(t). Phasors here are RMS phasors, so a "120 V" source has a phasor magnitude of 120, not 120·√2.
Why one number is not enough
For a resistor, voltage and current peak together, and all the power is absorbed. For an inductor or capacitor, the current is 90° out of step with the voltage. Energy flows into the element during part of each cycle and returns to the source during another part. The average power is zero, but the current still heats the wires.
Because of this, AC analysis splits power into a part that does work and a part that only shuttles back and forth.
Defining complex power
Let the voltage phasor be V = |V|∠θv and the current phasor be I = |I|∠θi. Complex power is
S = V · I*
where I* is the complex conjugate of I (same magnitude, negated angle). The result is a complex number:
S = P + jQ
The angle of S is θ = θv − θi. This is the same as the angle of the load impedance.
| Quantity | Symbol | Formula | Unit | Column | Column | Column | Column | Column | Column |
|---|---|---|---|---|---|---|---|---|---|
| Complex power | S | V·I* | volt-ampere (VA) | ||||||
| Apparent power | \ | S\ | \ | V\ | ·\ | I\ | VA | ||
| Real (average) power | P | \ | V\ | ·\ | I\ | ·cos θ | watt (W) | ||
| Reactive power | Q | \ | V\ | ·\ | I\ | ·sin θ | volt-ampere reactive (var) | ||
| Power factor | pf | P / \ | S\ | = cos θ | none |
For an inductive load, θ is positive, so Q is positive and the current lags the voltage (a "lagging" power factor). For a capacitive load, Q is negative and the power factor is "leading".
The power triangle
P, Q and |S| form a right triangle. P is the horizontal side, Q is the vertical side, and |S| is the hypotenuse, so |S|² = P² + Q². The angle between P and |S| is θ.
Computing it in code
A 120 V RMS source drives a load that draws 5 A RMS, lagging the voltage by 30°.
import cmath
import math
V = cmath.rect(120, 0) # volts RMS
I = cmath.rect(5, math.radians(-30)) # amps RMS, lagging
S = V * I.conjugate()
P = S.real
Q = S.imag
pf = P / abs(S)
print(S) # about (519.62+300j)
print(P, Q, abs(S)) # about 519.6 W, 300 var, 600 VA
print(pf) # about 0.866 (lagging)Note that I is conjugated before the multiplication. Without the conjugate, the angle would be θv + θi, and the sign of Q would be wrong.
Useful shortcuts
If you know the impedance Z = R + jX and the RMS current:
- P = |I|²·R
- Q = |I|²·X
- S = |I|²·Z
Resistors absorb only P. Ideal inductors and capacitors have only Q. In any circuit, total P and total Q are the sums of the individual P and Q values (conservation of complex power), so you can add the complex powers of parallel branches directly.
Exercise
A load Z = 3 + j4 Ω is connected to a 100 V RMS source. Find the current, then S, P, Q, and the power factor.
Show answer
|Z| = 5 Ω at 53.13°, so I = 100/5 = 20 A at −53.13°. S = V·I* = 100 × 20∠53.13° = 2000∠53.13° VA = 1200 + j1600. So P = 1200 W, Q = 1600 var (inductive), |S| = 2000 VA. pf = 1200/2000 = 0.6 lagging. Check: P = |I|²R = 400 × 3 = 1200 W.