Sub topic 14
Complex power and the power triangle
This chapter assumes you can already convert between rectangular and polar form, find an impedance Z = R + jX, and compute phasor currents with Ohm's law. It also assumes you know what RMS (root-mean-square) means for a sinusoid. Here you will turn phasor voltage and current into three power quantities and see how they relate.
Why power needs its own treatment
Phasor analysis gives you V and I as complex numbers. Power is a product of the time-domain waveforms, v(t) and i(t), and the product of two sinusoids of frequency ω is not a sinusoid of frequency ω. It contains a constant term and a term at 2ω. You therefore cannot multiply the phasors V and I directly and call the result power. The phasor shortcut works for linear operations at one frequency, and a product is not one of them.
Start from the time domain. Let v(t) = Vm cos(ωt + θv) and i(t) = Im cos(ωt + θi), and define the phase difference φ = θv − θi. Then:
p(t) = v(t) i(t) = ½ Vm Im [cos φ + cos(2ωt + θv + θi)]
The first term is constant. The second oscillates at twice the source frequency and averages to zero over a cycle. The average power is therefore:
P = ½ Vm Im cos φ
RMS values and the real power
The RMS value of a sinusoid is its amplitude divided by √2. Write Vrms = Vm/√2 and Irms = Im/√2. Then:
P = Vrms Irms cos φ
This is the real power (also called active power). It is the average rate at which energy is converted to heat, light, or mechanical work. Its unit is the watt (W).
Setting θv = 0 and rewriting the instantaneous power in terms of φ gives a second form:
p(t) = P (1 + cos 2ωt) + Q sin 2ωt, where Q = Vrms Irms sin φ
The first part never goes negative. It carries net energy to the load. The second part swings positive and negative with zero average. It is energy that a reactive element stores and returns every cycle. Q is the reactive power, with the unit volt-ampere reactive (var). It is not consumed, but it still loads the wires and sources that carry it.
Complex power
Complex power packages P and Q into one complex number:
S = V I*
Here V and I are RMS phasors and I* is the complex conjugate of I. If you use peak-amplitude phasors, as earlier chapters do, include the factor ½:
S = ½ V I*
Expand it with V = Vrms∠θv and I = Irms∠θi:
S = Vrms Irms ∠(θv − θi) = Vrms Irms cos φ + j Vrms Irms sin φ = P + jQ
The conjugate on I is what makes the angle of S equal to θv − θi. Without it you would get θv + θi, which has no physical meaning.
| Quantity | Symbol | Formula | Unit | Column | Column |
|---|---|---|---|---|---|
| Complex power | S | V I* = P + jQ | VA (volt-ampere) | ||
| Apparent power | \ | S\ | Vrms Irms | VA | |
| Real power | P | Re(S) = \ | S\ | cos φ | W |
| Reactive power | Q | Im(S) = \ | S\ | sin φ | var |
| Power factor | pf | P / \ | S\ | = cos φ | none |
The angle φ is the angle of the load impedance Z. For a load Z = R + jX, these equivalent forms follow from I = V/Z:
- S = Irms² Z, so P = Irms² R and Q = Irms² X.
- S = Vrms² / Z*, so the conjugate appears again.
The power triangle
Because S = P + jQ, the three quantities form a right triangle. P is the horizontal leg, Q is the vertical leg, and |S| is the hypotenuse. The angle between P and |S| is φ.
Sign conventions matter here:
- An inductive load has a positive X, so φ > 0 and Q > 0. Current lags voltage, and the power factor is called lagging.
- A capacitive load has a negative X, so φ < 0 and Q < 0. Current leads voltage, and the power factor is leading.
- A resistor has Q = 0 and pf = 1.
The power factor alone is ambiguous, because cos φ = cos(−φ). Always state "lagging" or "leading" with the number.
Worked example in code
A load Z = 8 + j6 Ω is connected to a 120 V RMS source at 0°. By hand, |Z| = 10 Ω and the angle is 36.87°, so I = 12∠−36.87° A. Then S = 120 × 12∠36.87° = 1440∠36.87° VA, which is 1152 + j864 VA. The code checks this.
import cmath
import math
V = cmath.rect(120, 0) # RMS phasor, volts
Z = complex(8, 6) # ohms
I = V / Z # RMS phasor, amps
S = V * I.conjugate() # complex power
P = S.real
Q = S.imag
print(f"I = {abs(I):.2f} A at {math.degrees(cmath.phase(I)):.2f} deg")
print(f"S = {P:.1f} + j{Q:.1f} VA")
print(f"|S| = {abs(S):.1f} VA, pf = {P / abs(S):.3f}")
print("lagging" if Q > 0 else "leading" if Q < 0 else "unity")The output is approximately:
I = 12.00 A at -36.87 deg
S = 1152.0 + j864.0 VA
|S| = 1440.0 VA, pf = 0.800
laggingThe load uses 1152 W, but the source must supply 1440 VA. The 864 var of reactive power is the gap between the two.
Conservation of complex power
In any circuit at a single frequency, the complex power delivered by the sources equals the sum of the complex powers absorbed by all elements. This means real power adds and reactive power adds, each separately. If one branch has S1 = P1 + jQ1 and another has S2 = P2 + jQ2, the total is (P1 + P2) + j(Q1 + Q2). A capacitor's negative Q cancels an inductor's positive Q in the sum.
Apparent power does not add this way. |S1| + |S2| is generally larger than |S1 + S2|, because the two complex numbers point in different directions. Adding apparent powers is the most common arithmetic error in this topic.
Power factor correction
A utility must size wires and transformers for the current. For a fixed real power P at a fixed voltage, a lower power factor means a larger current: Irms = P / (Vrms pf). Wire losses scale with Irms², so a poor power factor wastes energy in the supply path even though the load itself uses only P.
Most industrial loads are inductive. You can cancel part of the positive Q by placing a capacitor in parallel with the load. A parallel capacitor does not change the load's own voltage or its P. It only adds a negative Q of −Vrms² ω C.
Suppose you want to raise the pf of the load above from 0.80 lagging to 0.95 lagging at 60 Hz. The target reactive power is Q' = P tan(arccos 0.95). The capacitor must supply Qc = Q − Q'. Then C = Qc / (ω Vrms²).
import math
P = 1152.0 # W
Q = 864.0 # var, inductive
V = 120.0 # V RMS
f = 60.0 # Hz
pf_target = 0.95
w = 2 * math.pi * f
Q_new = P * math.tan(math.acos(pf_target))
Qc = Q - Q_new
C = Qc / (w * V**2)
S_new = math.hypot(P, Q_new)
print(f"Q after correction = {Q_new:.1f} var")
print(f"capacitor = {C * 1e6:.1f} uF")
print(f"line current = {S_new / V:.2f} A (was 12.00 A)")The output is approximately a 378.6 var remainder, a 89.4 µF capacitor, and a 10.11 A line current. The load still draws the same 1152 W, but the source now delivers 10.11 A instead of 12 A.
Common errors
- Forgetting the conjugate. Computing V I instead of V I* gives an angle of θv + θi. The result changes whenever you shift the time reference, which signals the mistake.
- Mixing peak and RMS. With peak phasors, S = ½ V I. With RMS phasors, S = V I. Mixing the two gives a factor-of-2 error. State which convention you use before you start.
- Treating |S| as a sum. Add the complex values, then take the magnitude.
- Dropping the sign of Q. Q is negative for capacitive loads. If you take magnitudes too early, inductors and capacitors appear to add reactive power instead of cancelling it.
- Reporting pf without lead or lag. Give both the number and the direction.
- Using the wrong voltage in S = Vrms²/Z\*. The V must be the voltage across that load, not the source voltage, unless they are the same.
Exercises
Exercise
A load has an RMS voltage of 230∠0° V and draws an RMS current of 5∠−30° A. Find S, P, Q, and the power factor, and state whether the pf is lagging or leading.
Show answer
S = V I* = 230 × 5 ∠(0 − (−30°)) = 1150∠30° VA. P = 1150 cos 30° ≈ 995.9 W. Q = 1150 sin 30° = 575 var. The pf = cos 30° ≈ 0.866. Q is positive and the current lags the voltage, so the pf is lagging.
Exercise
Two loads are in parallel on the same source. Load 1 has S1 = 600 + j800 VA. Load 2 has S2 = 400 − j300 VA. Find the total complex power, the total apparent power, and compare it with |S1| + |S2|.
Show answer
Add the complex values: S = (600 + 400) + j(800 − 300) = 1000 + j500 VA. The total apparent power is |S| = √(1000² + 500²) ≈ 1118 VA. The individual magnitudes are |S1| = 1000 VA and |S2| = 500 VA, whose sum is 1500 VA. This is larger than 1118 VA, so apparent powers do not add.
Exercise
A series circuit has R = 30 Ω and a capacitor with reactance −40 Ω (so Z = 30 − j40 Ω). It carries an RMS current of 2 A. Find P and Q, and say whether the pf is leading or lagging.
Show answer
Use S = Irms² Z = 4 × (30 − j40) = 120 − j160 VA. So P = 120 W and Q = −160 var. The Q is negative, so the load is capacitive and the pf is leading. The pf is 120/200 = 0.6, since |S| = √(120² + 160²) = 200 VA.