Sub topic 11
Checking That People Measure the Same Way
Assume you know the DMAIC phases, basic process terminology, and the difference between a sample and a population. This chapter focuses on the measurement system, which is the people, definitions, tools, forms, and methods used to collect data.
A measurement system must produce dependable results. If two trained people inspect the same invoice and reach different conclusions, the process data may show disagreement that does not exist in the process itself. Before analyzing causes, check whether the measurement method is consistent.
What to check
Measurement consistency has two main parts:
- Repeatability: The same person measures the same item the same way more than once.
- Reproducibility: Different people measure the same item and reach the same result.
For a continuous measurement, such as delivery time or package weight, you can compare repeated readings and calculate variation. For an attribute measurement, such as pass/fail, compare the decisions made by multiple appraisers.
Consistency does not prove accuracy. Two people can agree on the wrong result. To check accuracy, compare their decisions with a trusted reference standard when one exists.
| Question | What it checks | Example |
|---|---|---|
| Do appraisers agree with each other? | Reproducibility | Two auditors classify the same invoices |
| Does one appraiser repeat the decision? | Repeatability | One auditor classifies the same invoice twice |
| Do decisions match a known standard? | Accuracy | An auditor classifies test invoices with known defects |
Attribute agreement study
An attribute agreement study uses a common set of items. Each appraiser evaluates every item independently, without seeing another appraiser's result. Include clear examples of both outcomes and include borderline cases. Borderline cases reveal weaknesses in the operational definition.
Calculate simple percent agreement as:
\[ \text{agreement} = \frac{\text{number of matching decisions}}{\text{total decisions}} \]
For example, if two appraisers agree on 8 of 10 invoices, their agreement is 80%. This calculation is easy to explain, but it does not account for agreement that could happen by chance. For important decisions, use a statistic such as Cohen's kappa or a formal attribute agreement analysis.
appraiser_a = ["pass", "fail", "pass", "pass", "fail",
"pass", "fail", "pass", "pass", "fail"]
appraiser_b = ["pass", "fail", "pass", "fail", "fail",
"pass", "fail", "pass", "pass", "pass"]
matches = sum(a == b for a, b in zip(appraiser_a, appraiser_b))
agreement = matches / len(appraiser_a)
print(f"Matching decisions: {matches}/{len(appraiser_a)}")
print(f"Agreement: {agreement:.0%}")The result is 8 matching decisions out of 10, or 80% agreement. Set the acceptance threshold before reviewing the results. A high-risk inspection may require near-perfect agreement, while an early screening measure may tolerate less.
Finding the cause of disagreement
Do not immediately retrain everyone when agreement is low. First review the disagreements. Look for patterns:
- Does disagreement occur only for one defect type?
- Do appraisers use different source documents?
- Is the item hard to see, access, or interpret?
- Does the form allow ambiguous responses?
- Are the instructions missing examples?
- Does one appraiser consistently classify more items as defective?
A disagreement matrix can help. Record the item, each appraiser's decision, the reference decision if available, and the reason for disagreement. Revise the operational definition when the rule is unclear. Improve the tool or form when the procedure is difficult to follow. Train appraisers only after the method itself is clear.
A practical check sequence
Use representative items rather than only easy examples. Repeat some items when checking repeatability, but hide their identity from the appraisers. Document the date, appraiser, item, decision, and comments. Store the study results with the data collection plan.
Exercise
Two appraisers agree on 17 of 20 attribute decisions. What is their simple percent agreement, and what should you do before accepting the measurement system?
Show answer
Their agreement is 17 ÷ 20 = 85%. Compare that result with the predefined threshold, review the five disagreements for patterns, and check accuracy against a reference standard if one exists.