Sub topic 13
Power over Ethernet
This chapter assumes you know the cabling basics from the previous chapters (twisted pair categories, RJ45) and what a switch does. Power over Ethernet (PoE) sends electrical power and data over the same twisted-pair cable. That removes the need for a nearby wall outlet at each device.
Why PoE matters
PoE suits devices that are mounted where outlets are scarce: wireless access points on ceilings, IP cameras, VoIP phones, and badge readers. One cable run carries both the network connection and the power. A technician also gets central control, because a switch or UPS-backed injector can supply power to many devices at once.
The two roles
- Power sourcing equipment (PSE) supplies the power. This is a PoE switch (called an endspan) or a standalone PoE injector (called a midspan).
- Powered device (PD) receives the power. Examples are access points, cameras, and phones.
A PoE injector sits between a non-PoE switch and the device. It has a data-in port and a data-and-power-out port. Use it when the switch has no PoE support.
PoE negotiates before it sends power. The PSE detects whether the connected device is a PD and how much power it needs. A normal laptop or desktop NIC is not damaged by a PoE port, because the PSE sends full power only to a recognized PD.
PoE standards
| Standard | Name | Max power at PSE | Typical use |
|---|---|---|---|
| 802.3af | PoE | 15.4 W | VoIP phones, basic access points |
| 802.3at | PoE+ | 30 W | Dual-band access points, PTZ cameras |
| 802.3bt | PoE++ (Type 3 and 4) | 60 W and 100 W | Wi-Fi 6 access points, displays, laptops |
The power available at the device is lower than at the PSE, because some is lost in the cable. For example, 802.3af guarantees about 12.95 W at the PD.
Cabling limits
PoE uses the same 100 m (328 ft) maximum run as Ethernet over twisted pair. Use Cat 5e or better. Higher-power standards generate more heat in bundled cables, so Cat 6 or better is a sensible choice for 802.3bt.
Common problems
- Device does not power on. The switch port may not support PoE, or the switch's total power budget is used up. Each PoE switch has a fixed budget, such as 120 W, shared across all ports.
- Device reboots under load. The device may need more power than the standard provides. For example, an 802.3af port may not run an access point that requires PoE+.
- Intermittent failures. Check for a damaged cable, a poor termination, or a run longer than 100 m.
- Mixed equipment. Standards are generally backward compatible, but a PD that needs 802.3at will not run properly on an 802.3af port.
Exercise
A ceiling-mounted access point needs about 25 W. The nearest switch supports only 802.3af, and no outlet is nearby. What is the simplest fix that keeps one cable to the device?
Show answer
Add an 802.3at (PoE+) injector, or replace the switch with a PoE+ switch. The 802.3af port provides at most 15.4 W, which is not enough for a 25 W device. An 802.3at source provides up to 30 W.
Exercise
What is the difference between an endspan and a midspan PSE?
Show answer
An endspan is a PoE switch that has PoE built in. A midspan is a separate PoE injector placed between a non-PoE switch and the powered device.