Sub topic 10
Network Cabling: Copper and Fiber
This chapter assumes you know what a LAN is, that data moves as signals over a medium, and that Ethernet is the common wired standard. It covers the cable types tested on A+ Core 1: twisted pair, coaxial and fiber. Connectors, which attach to these cables, are covered in the next chapter.
Why the Cable Type Matters
A cable limits three things: how fast data can move, how far a signal can travel before it weakens, and how well it resists interference. Picking a cable is a trade-off between these limits and cost.
Copper cables carry electrical signals. They are cheap and easy to terminate, but they are sensitive to electromagnetic interference (EMI), which is noise from motors, fluorescent lights and power lines. Fiber cables carry pulses of light. They are immune to EMI and reach much farther, but the cable, optics and tools cost more.
Twisted Pair Copper
Twisted pair is the standard cable for Ethernet in offices and homes. It contains four pairs of copper wires, eight wires in total. Each pair is twisted together. The twisting cancels much of the interference that one wire would otherwise pick up from its neighbor, a problem called crosstalk.
UTP and STP
- UTP (unshielded twisted pair) has no metal shield. It is cheaper, more flexible and the most common type.
- STP (shielded twisted pair) wraps the pairs in foil or braided metal. The shield blocks EMI, so STP suits factory floors, areas near heavy electrical equipment, or runs beside power cables. The shield must be grounded properly through the connectors and jacks to work.
Categories
Cable categories (Cat) describe the tested performance of the cable. A higher number generally means a higher rated speed and frequency.
| Category | Typical maximum speed | Rated frequency | Notes |
|---|---|---|---|
| Cat 5 | 100 Mbps | 100 MHz | Obsolete |
| Cat 5e | 1 Gbps | 100 MHz | Reduced crosstalk compared with Cat 5 |
| Cat 6 | 1 Gbps (10 Gbps up to about 55 m) | 250 MHz | Often has a spline separating the pairs |
| Cat 6a | 10 Gbps | 500 MHz | Full 100 m at 10 Gbps. The "a" means augmented |
| Cat 7 | 10 Gbps | 600 MHz | Shielded. Not formally recognized by TIA |
| Cat 8 | 25 or 40 Gbps | 2000 MHz | Short runs, mainly in data centers |
For copper Ethernet, the maximum length of a segment is 100 meters (328 feet). This includes the cable from the wall jack to the device and from the patch panel to the switch. Going beyond this causes attenuation, which is signal loss over distance, and leads to errors or a dropped link.
Plenum and Riser Ratings
Cable jackets are also rated for where they run.
- Plenum cable (CMP) is for air-handling spaces, such as the area above a drop ceiling or under a raised floor. Its jacket resists fire and produces little toxic smoke when it burns. It costs more.
- Riser cable (CMR) is for vertical runs between floors.
- PVC (general-purpose) jackets are cheaper but give off toxic fumes when burned. They are not allowed in plenum spaces.
Fire codes drive this choice. A common exam scenario asks which cable to run above a drop ceiling. The answer is plenum.
Solid Core and Stranded Core
- Solid core uses a single copper conductor per wire. It performs well over long runs and is used for permanent installation behind walls, to patch panels and wall jacks. It breaks if bent repeatedly.
- Stranded core uses many thin strands per wire. It is flexible and suits patch cables between a computer and a wall jack.
Straight-Through and Crossover Wiring
Ethernet cables follow the wiring standards T568A and T568B, which define the order of the eight wires in the connector.
- A straight-through cable uses the same standard on both ends (usually T568B). It connects unlike devices, such as a PC to a switch.
- A crossover cable uses T568A on one end and T568B on the other. It connected like devices directly, such as a PC to a PC. Modern network interfaces use auto-MDI/MDIX, which detects and corrects the wiring, so crossover cables are rarely needed now.
The T568B order, left to right with the clip facing away from you, is: white/orange, orange, white/green, blue, white/blue, green, white/brown, brown.
Coaxial Cable
Coaxial (coax) cable has a central copper conductor surrounded by insulation, a metal shield, and an outer jacket. All layers share the same axis, which gives the cable its name. The shield makes coax resistant to interference.
On modern networks, coax mainly appears in two places:
- Cable internet and television. The cable modem connects to the provider through coax, usually RG-6.
- Older installations. RG-59 is thinner and has higher signal loss. It suits short runs, such as video or older cable TV.
| Type | Common use | Notes |
|---|---|---|
| RG-6 | Cable TV, cable internet, satellite | Thicker, lower loss over distance |
| RG-59 | Short video runs, older CCTV | Thinner, more loss, short distances |
Old 10BASE2 and 10BASE5 Ethernet networks also ran on coax, but these are obsolete.
Fiber-Optic Cable
Fiber cable has a glass (or sometimes plastic) core that carries light from a laser or LED. The core is wrapped in cladding, which reflects light back into the core, then a protective coating and a jacket. Because it carries light, fiber is immune to EMI and does not leak signals that could be tapped easily. It also supports long distances and very high speeds.
Single-Mode and Multimode
| Feature | Single-mode (SMF) | Multimode (MMF) |
|---|---|---|
| Core diameter | About 9 microns | 50 or 62.5 microns |
| Light source | Laser | LED or VCSEL (a low-cost laser) |
| Typical distance | Many kilometers (10 km to 100 km or more) | Up to a few hundred meters (about 300 to 550 m at 10 Gbps, depending on grade) |
| Cost | Higher optics cost | Lower optics cost |
| Typical use | Between buildings, ISP links, long backbones | Inside a building or campus, data centers |
| Jacket color (common) | Yellow | Orange or aqua |
Single-mode has a narrow core, so light travels in essentially one path. That reduces modal dispersion (signal spreading) and allows long distances. Multimode has a wider core, so light takes multiple paths, which limits the distance.
Fiber Trade-Offs
- Advantages: immunity to EMI, long distance, high bandwidth, better security against eavesdropping.
- Disadvantages: higher cost, more fragile (it can break if bent too tightly), and special tools are needed to terminate it.
- Mixing types: single-mode and multimode cannot be mixed on one link. The core sizes and optics do not match, and the result is heavy signal loss.
Choosing a Cable
Common Errors and Edge Cases
- Exceeding 100 m on copper. Symptoms are slow speeds, link flapping or no link. Fix it by shortening the run or adding a switch or using fiber.
- Running UTP beside power cables. EMI causes errors. Move the cable, cross power lines at right angles, or use STP.
- Using a low-rated cable at a high speed. A Cat 5 cable on a 1 Gbps link may negotiate down to 100 Mbps or produce errors. Check the category printed on the jacket.
- Untwisting too much at the connector. Keeping the pairs twisted close to the connector (a common guideline is under about 0.5 inch) preserves crosstalk protection.
- Wrong jacket in a plenum space. PVC cable above a drop ceiling violates fire code.
- Bending fiber too tightly. Tight bends leak light and can crack the glass.
- Mismatched fiber. A single-mode transceiver on multimode cable, or the reverse, gives unreliable links.
Summary Table
| Medium | Signal | Strength | Limitation |
|---|---|---|---|
| UTP | Electrical | Cheap, easy to install | EMI sensitive, 100 m limit |
| STP | Electrical | Shielded against EMI | More costly, needs grounding |
| Coax | Electrical | Good shielding, cable internet | Bulky, not used for LAN wiring today |
| Multimode fiber | Light | Fast, EMI immune | Limited distance |
| Single-mode fiber | Light | Longest reach | Highest optics cost |
Exercise
A technician must connect two buildings that are 2 km apart and must avoid any interference from lightning and power equipment. Which cable should be used, and why can UTP not be used?
Show answer
Use single-mode fiber. The distance is far beyond the 100 m limit of twisted pair, and fiber carries light, so it is immune to EMI. Multimode would be limited to a few hundred meters.
Exercise
An installer must run network cable through the space above a drop ceiling that carries air for the building's ventilation. Which jacket rating is required, and should solid core or stranded core be used for the permanent run to the wall jack?
Show answer
Use plenum-rated (CMP) cable because it is fire resistant and low-smoke. Use solid core for the permanent run, because it performs better over distance. Stranded cable is for the short patch cables at each end.
Exercise
A user's PC connects to a 1 Gbps switch port through an old cable. The link runs at only 100 Mbps. The cable is 40 m long. What is the most likely cause?
Show answer
The cable is probably Cat 5, which is rated for 100 Mbps. The length is within the 100 m limit, so replacing it with Cat 5e or better should allow 1 Gbps.