Sub topic 2
Control devices and warning devices
This chapter assumes you know what a process step is, what a defect is, and how to read short Python snippets.
Control devices and warning devices
A control device, also called a shutdown device, stops the process until the error is fixed. A warning device, also called an alarm, alerts the operator but lets the process continue. Control devices are stronger because a warning only works if someone notices it and acts in time.
A machine that will not start while its guard is open is a control device. A buzzer that sounds when the guard is open is a warning device.
Contact, fixed-value, and motion-step methods
Shigeo Shingo described three methods for detecting or preventing an error:
- Contact method: a probe or sensor checks the shape, size, or presence of a part.
- Fixed-value method: the device checks that the right number of items is present, such as six screws in a kit.
- Motion-step method: the device checks that each required step happened, in the right order.
The following Python sketch applies the motion-step method. The order cannot move backward or skip a step:
from enum import Enum
class Status(Enum):
DRAFT = "draft"
PAID = "paid"
SHIPPED = "shipped"
ALLOWED = {
Status.DRAFT: {Status.PAID},
Status.PAID: {Status.SHIPPED},
Status.SHIPPED: set(),
}
def advance(current: Status, new: Status) -> Status:
if new not in ALLOWED[current]:
raise ValueError(f"Cannot move from {current.value} to {new.value}")
return newSource inspection: checking conditions before the error happens
Source inspection checks the conditions that lead to an error before the work starts. Zero quality control applies this idea to every item: a bad input stops the line before it becomes a defect.
Ranking options: eliminate, replace, facilitate, detect, mitigate
Rank candidate countermeasures from most to least effective:
- Eliminate: remove the source of the error.
- Replace: swap the task for a safer one.
- Facilitate: make the correct action easier, such as color-coded parts.
- Detect: catch the error immediately with a control or warning device.
- Mitigate: reduce the harm after the error occurs.
Choose the highest-ranked option that is practical. Detection still allows the error to happen, so prefer elimination or replacement when cost allows.
Exercise
A filling line can start with the wrong nozzle attached. Which ranked option should you try first, and why?
Show answer
Eliminate the error source by designing the nozzle so only the correct one fits the line. If that is not possible, replace or facilitate the task. Detection comes after because it lets the error occur first.