Sub topic 6
Contact, Fixed-Value, and Motion-Step Methods
Assume you understand a process as a sequence of inputs, actions, and outputs. You should also know the difference between an error and a defect. An error is an incorrect human action. A defect is the unwanted result that reaches the next process step or the customer. Poka-yoke methods reduce the chance that an error becomes a defect.
Shigeo Shingo grouped many mistake-proofing devices into three practical methods: contact, fixed-value, and motion-step. The best method depends on what condition makes the error possible.
Contact method
A contact method checks a physical characteristic through contact with the part, tool, or fixture. It may check shape, size, position, color, or the presence of a feature.
For example, a fixture may have an uneven arrangement of pins. A component with the correct orientation fits over the pins. A reversed component does not fit. The fixture prevents assembly rather than asking the operator to inspect orientation.
Contact methods work well when the correct and incorrect states have different physical properties.
Examples include:
- A connector shaped so it can enter only the correct socket.
- A gauge that accepts a part only when its diameter is within limits.
- A sensor that confirms a cover is closed before a machine starts.
- A tray with cavities shaped for specific components.
The device should detect the condition at the point where the error would occur. Checking the finished product later is weaker because time and material have already been spent.
Fixed-value method
A fixed-value method controls a defined quantity, number, length, or count. The process cannot continue until the required value is present.
For example, a repair kit may contain exactly six screws in a compartment. If one screw remains after assembly, the operator knows that a screw is missing. A torque tool may also require a fixed number of completed fastening cycles before it marks the job complete.
Fixed-value checks are useful when the error involves too many or too few actions or items.
Examples include:
- Counting every required component before closing a package.
- Using a dispenser that releases one measured amount of material.
- Requiring four fastening operations for a part with four holes.
- Limiting a batch to a specified number of units.
A count alone is not always enough. If the counter can be reset without correcting the problem, it creates a record without creating quality.
Motion-step method
A motion-step method checks whether a required sequence of actions has occurred. It is sometimes called a sequence or motion-step check.
For example, an operator may need to scan a part, place it in a fixture, tighten two fasteners, and press a release button. The release button remains disabled until the earlier steps are complete. Skipping the scan or tightening only one fastener stops the process.
Motion-step methods are appropriate when the error is caused by:
- Omitting a step.
- Performing steps in the wrong order.
- Performing a step at the wrong location.
- Moving a part before a required condition is met.
| Method | Main question | Typical countermeasure |
|---|---|---|
| Contact | Is the object or position physically correct? | Shaped fixture or sensor |
| Fixed-value | Is the required quantity complete? | Counter or measured dispenser |
| Motion-step | Did each required action occur in order? | Interlock or sequence control |
Selecting and testing a method
Start with the specific error, not a favorite device. Ask what must be true immediately before the defect could occur. That condition is the control point.
Then prefer a control that physically stops the process. A warning light is useful when stopping is unsafe or impractical, but it depends on a person noticing and responding to it.
Test the device with deliberate errors:
- Try the reversed part.
- Remove one item from the required quantity.
- Skip and reorder each required step.
- Try to continue after a failed check.
- Check whether a simple workaround defeats the control.
Exercise
An operator must place three washers on a bolt before tightening it. Which method is the best starting point, and what additional test should you perform?
Show answer
Start with a fixed-value method, such as a dispenser or count check that confirms three washers were used. Test the device with two and four washers, and check whether the operator can reset or bypass the count without correcting the quantity.