Sub topic 13
When KVL needs care: lumped-element assumption and Faraday's law
This chapter assumes you can write a KVL loop equation, apply the passive sign convention, and use Ohm's law. Here you learn when the textbook form of KVL, where the voltages around a loop sum to zero, is only an approximation.
The two assumptions behind KVL
The loop-sum form of KVL rests on two assumptions:
- The lumped-element model. Each component is a point-like object with a single voltage across its terminals. Wires are ideal, so they have no voltage drop and no stored energy.
- No changing magnetic flux through the loop. The electric field around the loop must be conservative, which means voltage between two points does not depend on the path taken.
If both hold, energy conservation gives you the familiar result: the sum of the voltages around any closed loop is zero.
Where the lumped model stops working
A circuit counts as lumped when signals cross it much faster than they change. A signal at frequency f travels at speed c in the medium, so its wavelength is λ = c/f. The lumped model is reasonable when the largest circuit dimension d is much smaller than the wavelength.
A common rule of thumb is d < λ/10. The table shows how this plays out.
| Frequency | Wavelength in free space | Rule-of-thumb size limit |
|---|---|---|
| 60 Hz | 5000 km | 500 km |
| 1 MHz | 300 m | 30 m |
| 100 MHz | 3 m | 0.3 m |
| 2.4 GHz | 12.5 cm | 1.25 cm |
A bench circuit at 60 Hz is lumped by a wide margin. A 30 cm cable at 2.4 GHz is not. There, the voltage along a wire depends on position and time, so "the voltage at a node" is no longer a single number. You then need transmission-line or full electromagnetic analysis.
Faraday's law and the loop sum
The more common problem at low frequency is a changing magnetic field. Faraday's law says that the electromotive force (emf) around a closed path equals the negative rate of change of the magnetic flux Φ through that path:
emf = −dΦ/dt
When flux through a loop changes, the electric field is no longer conservative. Going once around the loop, the voltages measured across the elements do not sum to zero. They sum to the induced emf.
Ideal circuit theory handles this by moving the effect into a component. An inductor is the lumped model of flux that is confined inside the component. Its voltage is v = L di/dt, and you include it as an element in the KVL sum. With that bookkeeping, KVL still holds for the circuit.
KVL needs care when flux is not confined to a component. Examples include a transformer's stray flux, a long wire loop near a power cable, and a large loop in a noisy environment. In these cases the loop itself acts as a pickup coil and a stray emf appears in it.
A worked estimate of stray pickup
Suppose a loop of wire has area 0.01 m² and sits in a uniform field that varies as B(t) = B₀ sin(2πft). The flux is Φ = B·A, so the peak induced emf is 2πf·B₀·A.
import math
f = 60.0 # hertz, mains frequency
B0 = 100e-6 # tesla, peak field near a power cable
A = 0.01 # square meters, loop area
emf_peak = 2 * math.pi * f * B0 * A
print(f"Peak induced emf = {emf_peak * 1000:.3f} mV")The result is about 0.377 mV. This is negligible for a power circuit, but it can swamp a microvolt-level sensor signal. Reducing the loop area, for example by twisting the wires together, reduces the pickup in direct proportion.
Summary of when to worry
- Check dimensions against wavelength when frequencies reach the tens of megahertz or higher.
- Check for changing flux that is not captured by an inductor or transformer in your model.
- For ordinary DC and low-frequency circuits with compact wiring, apply KVL as usual.
Exercise
A 0.5 m long circuit operates at 300 MHz. Use the d < λ/10 rule with c = 3×10⁸ m/s to decide whether the lumped model, and so plain KVL, is appropriate.
Show answer
The wavelength is λ = c/f = (3×10⁸)/(300×10⁶) = 1 m. The limit is λ/10 = 0.1 m. The circuit is 0.5 m long, which is larger than 0.1 m, so the lumped model is not appropriate. Use transmission-line analysis instead.
Exercise
A measurement loop of area 0.04 m² sits in a 50 Hz field with peak flux density 200 µT. Find the peak induced emf, and say what happens to it if you twist the leads so the effective area drops to 0.004 m².
Show answer
The peak emf is 2π·50·200×10⁻⁶·0.04 ≈ 2.51 mV. Reducing the area by a factor of ten reduces the emf by the same factor, to about 0.251 mV.