Sub topic 13
When KVL Needs Care: Lumped-Element Assumption and Faraday's Law
This chapter assumes you can write KVL equations with the passive sign convention, and that you know the energy argument for why the loop sum is zero. Here you will see where that argument breaks down. You will learn when the usual form of KVL is an approximation, and what to do instead.
KVL rests on an assumption
In earlier chapters, KVL said that the voltages around any closed loop add up to zero. The energy argument went like this: a charge that travels around a closed path and returns to its start must have the same energy it began with. So the rises and drops along the path must cancel.
That argument holds only if the voltage between two points depends on the two points and not on the path between them. In physics terms, the electric field must be conservative. In a circuit, this is true when two conditions hold:
- No changing magnetic flux passes through the loop you are tracing.
- The circuit is small enough that signals can be treated as arriving everywhere at once.
The second condition is the lumped-element assumption. Under it, each component is a point-like device with two terminals. All the electric and magnetic effects are confined inside the component. The wires between components are ideal and carry no voltage, and no energy is stored in the space around them.
KVL as taught in circuit analysis is therefore a consequence of the lumped model. It is not an unconditional law of nature. Inside the model it is exact, and outside it you need a more general tool.
Faraday's law: the general statement
Maxwell's equations give the general rule. Faraday's law of induction says that the electromotive force (emf) around a closed path equals the negative rate of change of magnetic flux through the surface that path encloses:
emf around loop = −dΦ/dt
Here Φ is the magnetic flux, measured in webers. When the flux through the loop is constant, dΦ/dt is zero and the sum of voltages around the loop is zero. That is ordinary KVL. When the flux changes, the sum is not zero. The electric field is no longer conservative, and "the voltage between two points" depends on the path you choose.
Three situations produce a changing flux through a circuit loop:
- A nearby coil or transformer winding carries a changing current. Its magnetic field links your loop.
- A permanent magnet moves relative to the loop, or the loop moves in a magnetic field.
- An electromagnetic wave from a radio transmitter or a switching circuit passes through the loop.
How lumped circuits stay consistent
If Faraday's law allows a nonzero loop sum, why does KVL still work for inductors and transformers? Circuit theory handles this by choosing where to put the effect.
An inductor has a changing flux inside its windings. The lumped model assigns the whole induced emf to the inductor as a terminal voltage, v = L di/dt. The loop you trace through the external circuit does not enclose any of that flux, because the flux is confined inside the component. Along the external path, the electric field stays conservative, so KVL holds and the inductor simply appears as one more element with voltage v.
The model works as long as you draw your loops outside the components and the flux stays inside them. It fails when flux leaks into the space between components, so that the wiring itself encloses changing flux.
What the failure looks like
Consider a loop made of a resistor and a voltage source, in a region where an external magnetic field is increasing. The wires and the resistor enclose an area A. The changing field induces an emf in the loop. The ordinary KVL equation, with only the source and the resistor, leaves a residual that equals the induced emf.
The effect can be modeled by adding a voltage source to the loop that represents the induced emf. With that source included, KVL balances again. The value of the source is −dΦ/dt, where Φ is the flux through the loop area.
The code below estimates the induced emf in a loop sitting in a sinusoidal field, then finds the current that results when the loop contains a resistor.
import math
# Loop of area A in a uniform field B(t) = B0 * sin(2*pi*f*t),
# perpendicular to the loop. Flux = B(t) * A.
# Induced emf = -dPhi/dt = -A * B0 * 2*pi*f * cos(2*pi*f*t).
A = 0.01 # loop area in m^2 (10 cm by 10 cm)
B0 = 1e-3 # peak field in tesla (1 mT)
f = 50.0 # frequency in Hz
R = 10.0 # total loop resistance in ohms
emf_peak = A * B0 * 2 * math.pi * f
i_peak = emf_peak / R
print(f"Peak induced emf = {emf_peak * 1000:.3f} mV")
print(f"Peak loop current = {i_peak * 1000:.4f} mA")The peak emf is about 3.14 mV. That is small, but it is not zero. A sensitive measurement circuit with microvolt signals would be badly disturbed by it. Real instruments reduce this effect by shrinking the loop area. Twisted-pair cables do this: each twist reverses the sign of the enclosed flux, so adjacent twists cancel.
When the lumped assumption fails
The lumped model also fails when the circuit is large compared with the signal's wavelength. A signal at frequency f in a wire travels at a speed v that is a sizable fraction of the speed of light. Its wavelength is λ = v/f. If the circuit's physical size is comparable to λ, then different parts of a wire see different voltages at the same moment. The voltage across a wire is no longer zero, and a component's two terminals no longer carry the same current at the same instant.
A common rule of thumb is that lumped analysis is reasonable when the largest circuit dimension is less than about one tenth of the wavelength. The code below checks this for a few cases.
C = 3.0e8 # speed of light in m/s
def wavelength(freq_hz, velocity_factor=1.0):
"""Wavelength in metres for a signal on a line with the given velocity factor."""
return velocity_factor * C / freq_hz
cases = [
("Mains, 50 Hz", 50.0, 10.0),
("Audio, 20 kHz", 20e3, 1.0),
("Digital clock, 100 MHz", 100e6, 0.3),
("Wi-Fi, 2.4 GHz", 2.4e9, 0.1),
]
for name, f, size in cases:
lam = wavelength(f)
ratio = size / lam
verdict = "lumped OK" if ratio < 0.1 else "use distributed model"
print(f"{name:24s} wavelength = {lam:12.4g} m, size/lambda = {ratio:8.3g} -> {verdict}")Running it shows that a 10 m mains installation is tiny compared with a 6000 km wavelength, so lumped analysis is excellent. A 30 cm board carrying a 100 MHz clock has a size-to-wavelength ratio of about 0.1, which is borderline. A 10 cm Wi-Fi circuit at 2.4 GHz has a ratio of about 0.8, so it needs a distributed treatment such as transmission-line theory.
| Situation | Lumped KVL valid? | What to use instead |
|---|---|---|
| Small DC or low-frequency circuit | Yes | Standard KVL |
| Inductor or transformer with flux contained in the component | Yes | Terminal voltage v = L di/dt |
| Loop enclosing flux from an outside source | No | Add the induced emf −dΦ/dt as a source |
| Circuit size comparable to the wavelength | No | Transmission-line or full-wave analysis |
Path dependence in practice
When flux changes, a voltmeter reading depends on how its leads are routed. Two probes touching the same two points can read different values if the lead loops enclose different amounts of flux. This is a real measurement error, not a fault in the meter.
The diagram below shows the decision you make when you apply KVL.
Common mistakes
- Treating KVL as always true. It is true inside the lumped model. Check the two conditions before trusting a loop sum.
- Forgetting that inductors have voltage. An ideal inductor with changing current has a nonzero voltage. Include it in the loop sum.
- Ignoring loop area in sensitive circuits. Long, wide loops pick up flux from nearby switching supplies and motors. Keep signal and return wires close together.
- Using lumped analysis at high frequency. Compare the circuit size with the wavelength before you commit to the model.
Summary
KVL follows from a conservative electric field, which holds when no changing flux crosses the loop and the circuit is electrically small. Faraday's law gives the general case: the loop sum equals −dΦ/dt. Lumped models keep KVL valid by confining flux inside components and describing it as a terminal voltage. Where flux leaks into the wiring, add the induced emf as a source. Where the circuit is large compared with the wavelength, switch to distributed models.
Exercise
A rectangular loop of wire measures 20 cm by 5 cm and sits perpendicular to a uniform magnetic field that rises steadily from 0 to 2 mT over 10 ms. What emf is induced in the loop, and what is the sum of the resistor and source voltages that ordinary KVL would report as the "missing" amount?
Show answer
The area is 0.20 m × 0.05 m = 0.01 m². The flux changes by ΔΦ = 0.01 m² × 2×10⁻³ T = 2×10⁻⁵ Wb over 10 ms, so the average rate is 2×10⁻⁵ / 0.01 = 2×10⁻³ V, or 2 mV in magnitude. Ordinary KVL, which counts only the source and resistor voltages, would show a residual of 2 mV around the loop. Its sign is opposite to the change in flux, as Lenz's law requires.
Exercise
A circuit on a board is 15 cm across and carries a 1 GHz signal. The signal travels at about 0.5 times the speed of light on the board. Is the lumped assumption reasonable using the one-tenth wavelength rule?
Show answer
The wavelength is 0.5 × 3×10⁸ / 10⁹ = 0.15 m, so the circuit is as large as one full wavelength. The ratio is 1.0, far above 0.1, so the lumped assumption is not reasonable and a transmission-line model is needed.